Samsung DVM PLUS III Technical Data Book page 61

Hide thumbs Also See for DVM PLUS III:
Table of Contents

Advertisement

No. Error code
83
E-453
Overload error of outdoor unit's motor (by temperature).
84
E-454
RPM error of outdoor unit's motor
85
E-455
IPM overload error of outdoor unit's motor (by temperature)
86
E-456
Over Current error of outdoor unit's motor
87
E-457
Backlash error of outdoor unit's motor
88
E-458
Over current of CT sensor. (Or outdoor's motor locking of inverter system.)
89
E-461
Low current of CT sensor. (Or compressor starting failure of inverter system.)
Liquid refrigerant incoming protection error in digital / 1st fixed scroll compressor with sump temperature
90
E-477
sensor.
91
E-559
Indoor unit stop by unidentified error from outdoor units.
92
E-560
Option switch setting error of outdoor unit. (napplicable option switch turns on.)
93
E-561
Fan RPM error of ERV SA (Supply air).
94
E-562
Fan RPM error of ERV RA (Return air).
95
E-563
Model mismatching of Indoor unit.
96
E-601
Communication error between remote controller and indoor unit.
97
E-602
Communication error between master and slave wired remote controller.
98
E-603
Communication packet error (Baud rate error)
99
E-604
Tracking failure error between wired remote controller and indoor unit.
Communication error.
100
E-605
(7-day scheduler  Wired remote controller or 7-day scheduler  Centralized controller)
101
E-606
COM1/COM2 communication setting error. (Wired remote controller)
102
E-607
Two masters of wired remote controllers were installed in one COM2 communication line.
103
E-608
Can't detect ERV controller.
104
E-609
Indoor unit is not detected for synchronous control.
105
E-610
Communication error between centralized controller and interface module.
106
E-611
Communication error between DMS and centralized controller.
107
E-613
Communication error between DMS and SIM interface module.
108
E-614
Communication error between SIM and power meter.
109
E-615
Communication error between interface module and indoor unit.
110
E-616
Communication error between interface module and outdoor unit.
111
E-618
The connected indoor units to ERV exceeded 16 units.
112
E-619
Mixed temperature display setting of indoor units which was connected to MWR-WS00 (Celsius/Fahrenheit)
113
E-620
Temperature display setting error of MWR-WS00 (Celsius/Fahrenheit)
114
E-621
Option switch setting error of wired remote controller (Master/Slave)
115
E-652
Two wired remote controllers were set to the master mode. (COM 1 wiring)
116
E-653
Room temperature sensor in the wired remote controller. (Open or Short)
117
E-654
Memory data error in the wired remote controller. (MWR-WS00)
118
P-701
Floating switch error of indoor unit. (1st detection)
119
P-702
EEV closing error of indoor unit. (1st detection)
120
P-703
EEV opening error of indoor unit. (1st detection)