10.3.2.7 Current protection of compressor (ODU P3)
Current protection of compressor
Judge 1: Check whether the
input current of the power
supply wire is higher than max
protection current value
Yes
Check whether
the refrigerant
system is ok
Judge 2: Check whether the
outdoor ambient
temperature is higher than
50℃
No
Judge 3: Check whether the
outdoor unit is bad ventilation
No
Judge 4: Check whether the
heat exchanger is dirty
No
Judge 5: The refrigerant
pipe is blocked
No
Replace outdoor main
board,and check whether
the system can run normally
No
Replace the electric control box
M2OD-16H
M2OD-18HFN1
Model
FN1-Q
-Q(W190)
Max
prote
ction
11A
14A
curre
nt
Yes
Stop the unit
Yes
Make the outdoor unit ventilate well
Yes
Clean the heat exchanger
Let the refrigerant out, then use the high
Yes
pressure nitrogen or refrigerant to blow pipe,
vacuumize and charge the refrigerant again
Yes
Yes
Trouble is solved
M2OD-18H
M2OD-14H
M3OD-21H
FN1-Q
FN1-Q
FN1-Q
15A
14A
15A
M3OD-26H
M3OD-27H
M4OD-28H
FN1-Q
FN1-Q
FN1-Q
15A
18.5A
18A
M4OA-36H
M5OC-36H
M5OD-42H
FN1-Q
FN1-Q
FN1-Q
23A
23A
25A

Advertisement