10.2.4
Connect the Cable to the Outdoor Unit
1
Remove the control board cover from the
unit by loosening the screw.
2
Connection cable between indoor unit and
outdoor unit shall be approved
polychloroprene sheathed 4 × 1.5 mm
1.5HP) or 4 x 2.5 mm
cord, type designation 60245 IEC 57 or
heavier cord. Do not use joint connection
cable. Replace the wire if the existing wire
(from concealed wiring, or otherwise) is too
short.
3
Secure the cable onto the control board with
the holder (clamper).
4
Attach the control board cover back to the
original position with screw.
5
For wire stripping and connection requirement,
refer to instruction 10.1.7 of indoor unit.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.
10.2.5
Piping Insulation
1
Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation
Diagram. Please wrap the insulated piping end to prevent water from going inside the piping.
2
If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by
using POLY-E FOAM with thickness 6 mm or above.
2
(1.0 ~
2
(2.0 ~ 2.5HP) flexible