AWM-G2_(i) Table of Contents Table of Contents Nomenclature........................1 Indoor Unit ........................1 Outdoor Unit ........................2 Product Line-Up ........................3 Features..........................9 Application Information ....................10 Operating Range ......................10 Refrigerant Circuit Diagram ..................11 Controller ........................19 Installation Guideline ....................20 Sound Data ........................34 Sound Pressure Level ....................34 NC Curve ........................35 Engineering & Physical Data ...................38 General Data .......................38 Components Data ......................55 Performance Data ......................72...
Nomenclature AWM-G2_(i) Nomenclature Indoor Unit Brand : Acson Refrigerant “ “ : Omitted if R22 : R407C : R410A Model Name : Wall Mounted Capacity Index : 10,000 Btu/h : 20,000 Btu/h Chassis : G + Series Model Type “ “...
Nomenclature AWM-G2_(i) Outdoor Unit Brand : Acson Refrigerant “ “ : Omitted if R22 : R407C : R410A Model Name : Single Split Condensing Unit Capacity Index : 10,000 Btu/h : 20,000 Btu/h Chassis : C Series Model Type “ “...
Features AWM-G2_(i) Features Excellent Air Distribution Air discharge direction can be adjusted in four directions, manually or automatically by using LCD remote control. The new double louver design with automatic air swing function fully optimizes the room comfort by distributing the air evenly to the room. The unique skew fan design with larger diameter creates better air flow to the operating environment.
Application Information AWM-G2_(i) Application Information Operating Range Ensure the operating temperature is in allowable range. Cooling only Standard point Caution : The use of your air conditioner outside the range of working Low ambient kit temperature and humidity can result in serious failure. Indoor temp.
AWM-G2_(i) Application Information Controller SLEEP MODE TIMER TIMER TIMER CANCEL Operation Guide Transmission Source Operating Mode • The source where the signal will be transmitted. • Press the MODE button to select the type of operating mode. Signal Transmission Indication • For cooling only unit, the available modes are: COOL ( ), •...
Application Information AWM-G2_(i) Installation Guideline Safety Precautions WARNING CAUTION Please take note of the following important points • Installation and maintenance should be performed by when installing. qualified persons who are familiar with local code and • Do not install the unit where leakage of flammable regulation, and experienced with this type of appliance.
Page 23
AWM-G2_(i) Application Information Installation Diagram Indoor Unit Air Filter Front Frame Back Housing Air Intake ON/OFF Switch Grille Indicator Light Drain Hose Signal Receiver Air Intake Air Discharge Refrigerant Piping Nozzle Outdoor Unit Caution • Before installing the unit, ensure that the power supply matches the power requirement of the airconditioner.
Application Information AWM-G2_(i) Selection of Location and Space Indoor Unit Install the fan coil (indoor) unit at a location with the following requirements • Location is suitable for wiring, piping and drainage. • No obstruction of air flow into and out of unit where cooler air can be evenly distributed.(See fig. 1) •...
Page 25
AWM-G2_(i) Application Information Outdoor Unit As condensing temperature rises, evaporating temperature rises and cooling capacity drops. In order to achieve maximum cooling capacity, the location selected for outdoor unit should fulfill the following requirements : • Install the condensing (outdoor) unit in a way such that hot air distributed by the outdoor condensing unit cannot bedrawn in again (as in the case of short circuit of hot discharge air).
Page 26
Application Information AWM-G2_(i) Installation of Outdoor Unit Condensed Water Disposal of Outdoor Unit (Heat Pump Unit Only) • There are 2 holes on the base of outdoor unit for condensed water to flow out. Insert the drain elbow toone of the holes. • To install the drain elbow, first insert one portion of the hook to the base (portion A), then pull the drainelbow in the direction shown by the arrow while inserting the other portion to the base.
Page 27
AWM-G2_(i) Application Information Drilling Holes and Mounting Installation Installation Plate Caution • Please check the unit weight for each model. Always ensure that the wall is sufficiently strong to withstandthe weight. If not, it is necessary to reinforce the wall with plate, beams or pillars. • The unit cannot be directly fixed onto the wall or the likes. In all cases, the installation plate provided MUST be used. •...
Page 28
Application Information AWM-G2_(i) • Fixing method:- REINFORCED CONCRETE BUILDING WOODENFRAME WALL NUT ANCHOR BOLT ANCHOR Indoor Unit Preparation • The refrigerant piping can be routed to the unit in 5 direction, by using the cut outs in the unit casing. (See fig. 1) •...
AWM-G2_(i) Application Information Wiring Electrical Connection • Wiring regulation on wire diameters differ from country to country. Please refer to your LOCAL ELECTRICAL CODES for fi eld wiring rules. Be sure that installation comply with such rules and regulations. General Precautions •...
Page 30
Application Information AWM-G2_(i) • The exact length of pipe protruding from the face of the flare die is determined by the flaring tool. The table shows the use of an imperial die and riged die. A(mm) PIPE Ø, D (mm) IMPERIAL DIE RIGED DIE 6.35 (1/4”) 9.52 (3/8”)
Page 31
AWM-G2_(i) Application Information ii) Outdoor Installation Space Is Limited • If the orifice pipe can not be connected directly to the liquid valve due tolimitation space, it can be Step 4 connected between the liquid pipes. Orifice Pipe Step 3 Step 2 Step 1 •...
Page 32
Application Information AWM-G2_(i) VACUUMING AND CHARGING • The precharged outdoor unit does not need any vacuuming or charging. However once it is connected, the connecting pipe line and the indoor need to be vacuumed before releasing the R22/R407C/R410A from the outdoor unit. 1) Open the service port core cap. 2) Connect pressure gauge to the service port.
Page 33
• When the piping length is more than 7.6m, please use the table below : Additional charge in gram. R22 MODELS AWM 07G2 / 09G2 / 10G2 / 15G2 AWM 20G2 AWM 25G2 AWM 301 1030...
Page 34
Application Information AWM-G2_(i) Diagram shows typical charging method. Caution For R10A • Avoid prolong exposure of an opened compressor, or the internal part of refrigerant piping to moist air. The POE oil in the compressor and piping can absorb moisture from air. Final Checking •...
Page 35
AWM-G2_(i) Application Information ) CHARACTERISTIC • R410A liquid and vapor components have different compositions when the fluid evaporates or condenses. Hence, when leak occurs and only vapor leaks out, the composition of the refrigerant mixture left in the system will change and subsequently affect the system performance. DO NOT add new refrigerant to leaked system.
Sound Data AWM-G2_(i) Sound Data Sound Pressure Level 1/1 Octave Sound Pressure Level (dB, ref 20µPa) Speed Overall Noise Model (RPM) (dBA) Criteria 125 Hz 250 Hz 500 Hz 1k Hz 2k Hz k Hz k Hz High AWM 0G2 AWM 0G2/G2R Medium A5WM 0G2/G2R A5WM 0G2/G2R High AWM 10G2/G2R Medium A5WM 10G2/G2R High AWM 15G2/G2R Medium A5WM 15G2/G2R High AWM 20G2/G2R Medium A5WM 20G2/G2R High AWM 25G2/G2R Medium A5WM 25G2/G2R High...
AWM-G2_(i) Sound Data AWM 07/09G2/G2R , A5WM 07/09G2/G2R NC CURVES NC-45 NC-40 High Fan NC-35 Medium Fan NC-30 Low Fan NC-25 NC-20 1000 2000 4000 8000 Octave-band frequency (Hz) AWM 10G2/G2R , A5WM 10G2/G2R NC CURVES NC-45 NC-40 High Fan Medium Fan NC-35 NC-30 Low Fan...
Page 38
Sound Data AWM-G2_(i) AWM 15G2/G2R , A5WM 15G2/G2R NC CURVES NC-45 NC-40 High Fan NC-35 Medium Fan NC-30 NC-25 NC-20 Low Fan 1000 2000 4000 8000 Octave-band frequency (Hz) AWM 20G2/G2R , A5WM 20G2/G2R NC CURVES High Fan NC-45 Medium Fan NC-40 Low Fan NC-35...
Page 39
AWM-G2_(i) Sound Data AWM 25G2/G2R , A5WM 25G2/G2R NC CURVES High Fan Medium Fan NC-45 Low Fan NC-40 NC-35 NC-30 NC-25 NC-20 1000 2000 4000 8000 Octave-band frequency (Hz) AWM 301/301R , A5WM 311/301R NC CURVES NC-50 NC-45 High Fan NC-40 Medium Fan Low Fan NC-35...
Engineering & Physical Data AWM-G2_(i) Engineering & Physical Data General Data - Cooling Only (R22) INDOOR UNIT AWM 0G2 AWM 0G2 MODEL OUTDOOR UNIT ALC 0C ALC 0C Btu/h 7000 9000 NOMINAL CAPACITY 2050 2640 NOMINAL TOTAL INPUT POWER NOMINAL RUNNING CURRENT 2.70 4.10 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 3.47 2.87 REFRIGERANT TYPE...
Page 41
AWM-G2_(i) Engineering & Physical Data General Data - Cooling Only (R22) INDOOR UNIT AWM 10G2 AWM 15G2 MODEL OUTDOOR UNIT ALC 10C ALC 15C Btu/h 9500 12000 NOMINAL CAPACITY 2780 3520 NOMINAL TOTAL INPUT POWER 1200 NOMINAL RUNNING CURRENT 3.80 5.40 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 3.23 2.93 REFRIGERANT TYPE REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR CAP.
Page 42
Engineering & Physical Data AWM-G2_(i) General Data - Cooling Only (R22) INDOOR UNIT AWM 20G2 AWM 20G2 MODEL OUTDOOR UNIT ALC 1C ALC 20C Btu/h 18000 19000 NOMINAL CAPACITY 5280 5570 NOMINAL TOTAL INPUT POWER 1820 1807 NOMINAL RUNNING CURRENT 8.10 8.00 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 2.90 3.08 REFRIGERANT TYPE REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR CAP.
Page 43
AWM-G2_(i) Engineering & Physical Data General Data - Cooling Only (R22) INDOOR UNIT AWM 25G2 AWM 01 MODEL OUTDOOR UNIT ALC 25C ALC 2C Btu/h 23500 27000 NOMINAL CAPACITY 6890 7913 NOMINAL TOTAL INPUT POWER 2530 2708 NOMINAL RUNNING CURRENT 11.30 13.10 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 2.72 3.00 REFRIGERANT TYPE REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR CAP.
Page 44
Engineering & Physical Data AWM-G2_(i) General Data - Cooling Only (R22) INDOOR UNIT AWM 01 MODEL OUTDOOR UNIT ALC 0C Btu/h 30000 NOMINAL CAPACITY 8790 NOMINAL TOTAL INPUT POWER 2944 NOMINAL RUNNING CURRENT 12.60 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 2.99 REFRIGERANT TYPE REFRIGERANT CONTROL (EXPANSION DEVICE) EXTERNAL ORIFICE KIT AUTO LOUVER (UP & DOWN) & AIR DISCHARGE GRILLE (LEFT & RIGHT) CONTROL OPERATION LCD REMOTE CONTROL...
Page 45
AWM-G2_(i) Engineering & Physical Data General Data - Heat pump (R22) INDOOR UNIT AWM 0G2R AWM 10G2R MODEL OUTDOOR UNIT ALC 0CR ALC 10CR Btu/h 8800 9500 NOMINAL COOLING CAPACITY 2580 2780 Btu/h 8600 9500 NOMINAL HEATING CAPACITY 2520 2780 NOMINAL TOTAL INPUT POWER (COOLING) NOMINAL TOTAL INPUT POWER (HEATING) NOMINAL RUNNING CURRENT (COOLING) 4.00 3.80 NOMINAL RUNNING CURRENT (HEATING) 3.40 3.40 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 2.84 3.23 3.36...
Page 46
Engineering & Physical Data AWM-G2_(i) General Data - Heat pump (R22) INDOOR UNIT AWM 15G2R AWM 20G2R MODEL OUTDOOR UNIT ALC 15CR ALC 1CR Btu/h 12000 18000 NOMINAL COOLING CAPACITY 3520 5280 Btu/h 12000 18400 NOMINAL HEATING CAPACITY 3520 5390 NOMINAL TOTAL INPUT POWER (COOLING) 1100 1820 NOMINAL TOTAL INPUT POWER (HEATING) 1660 NOMINAL RUNNING CURRENT (COOLING) 5.00 8.10 NOMINAL RUNNING CURRENT (HEATING) 4.50 7.40 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 3.20 2.90...
Page 47
AWM-G2_(i) Engineering & Physical Data General Data - Heat pump (R22) INDOOR UNIT AWM 20G2R AWM 25G2R MODEL OUTDOOR UNIT ALC 20CR ALC 25CR Btu/h 19000 23500 NOMINAL COOLING CAPACITY 5570 6890 Btu/h 19500 24000 NOMINAL HEATING CAPACITY 5720 7030 NOMINAL TOTAL INPUT POWER (COOLING) 1807 2530 NOMINAL TOTAL INPUT POWER (HEATING) 1757 2450 NOMINAL RUNNING CURRENT (COOLING) 8.00 11.30 NOMINAL RUNNING CURRENT (HEATING) 7.80 11.10 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 3.08 2.72...
Page 48
Engineering & Physical Data AWM-G2_(i) General Data - Heat pump (R22) INDOOR UNIT AWM 01R AWM 01R MODEL OUTDOOR UNIT ALC 2CR ALC 0CR Btu/h 27000 30000 NOMINAL COOLING CAPACITY 7913 8790 Btu/h 27000 30000 NOMINAL HEATING CAPACITY 7913 8790 NOMINAL TOTAL INPUT POWER (COOLING) 2708 2944 NOMINAL TOTAL INPUT POWER (HEATING) 2273 2864 NOMINAL RUNNING CURRENT (COOLING) 13.20 14.30 NOMINAL RUNNING CURRENT (HEATING) 13.30 13.70 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 2.92 2.99...
Page 49
AWM-G2_(i) Engineering & Physical Data General Data - Cooling Only (R22) INDOOR UNIT A5WM 0G2 A5WM 0G2 MODEL OUTDOOR UNIT A5LC 0C A5LC 10C Btu/h 7500 9000 NOMINAL CAPACITY 2200 2640 NOMINAL TOTAL INPUT POWER NOMINAL RUNNING CURRENT 2.90 3.90 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 3.55 3.07 REFRIGERANT TYPE R410A R410A REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR CAP.
Page 50
Engineering & Physical Data AWM-G2_(i) General Data - Cooling Only (R10A) INDOOR UNIT A5WM 10G2 A5WM 15G2 MODEL OUTDOOR UNIT A5LC 10C A5LC 15C Btu/h 9500 12000 NOMINAL CAPACITY 2780 3520 NOMINAL TOTAL INPUT POWER 1230 NOMINAL RUNNING CURRENT 3.90 5.40 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 3.05 2.86 REFRIGERANT TYPE R410A R410A REFRIGERANT CONTROL (EXPANSION DEVICE)
Page 51
AWM-G2_(i) Engineering & Physical Data General Data - Cooling Only (R10A) INDOOR UNIT A5WM 20G2 A5WM 25G2 MODEL OUTDOOR UNIT A5LC 20C A5LC 25C Btu/h 17850 / <18000> 20350 / <22500> NOMINAL CAPACITY-1Ø/ <Ø> 5230 / <5280> 5960 / <6590> NOMINAL TOTAL INPUT POWER-1Ø/ <Ø> 1630 / <1663> 1860 / <2195> NOMINAL RUNNING CURRENT-1Ø/ <Ø> 7.3 / <3.2> 8.4 / <4.2> POWER SOURCE-1Ø/ <Ø> V/Ph/Hz 220-240/ 1/ 50 / <380-415/ 3/ 50>...
Page 52
Engineering & Physical Data AWM-G2_(i) General Data - Cooling Only (R10A) INDOOR UNIT A5WM 11 MODEL OUTDOOR UNIT A5LC 2C Btu/h 26000 / <26000> NOMINAL CAPACITY-1Ø/ <Ø> 7620 / <7620> NOMINAL TOTAL INPUT POWER-1Ø/ <Ø> 2560 / <2631> NOMINAL RUNNING CURRENT-1Ø/ <Ø> 12.2 / <4.6> POWER SOURCE-1Ø/ <Ø> V/Ph/Hz 220-240/ 1/ 50 / <380-415/ 3/ 50> EER-1Ø/ <Ø> 2.98 / <2.90> REFRIGERANT TYPE R410A REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR CAP.
Page 53
AWM-G2_(i) Engineering & Physical Data General Data - Heat pump (R10A) INDOOR UNIT A5WM 0G2R A5WM 0G2R MODEL OUTDOOR UNIT A5LC 0CR A5LC 10CR Btu/h 7500 9000 NOMINAL COOLING CAPACITY 2200 2640 Btu/h 7500 9000 NOMINAL HEATING CAPACITY 2200 2640 NOMINAL TOTAL INPUT POWER (COOLING) NOMINAL TOTAL INPUT POWER (HEATING) NOMINAL RUNNING CURRENT (COOLING) 3.10 3.90 NOMINAL RUNNING CURRENT (HEATING) 2.60 3.40 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 3.24 3.07 4.00...
Page 54
Engineering & Physical Data AWM-G2_(i) General Data - Heat pump (R10A) INDOOR UNIT A5WM 10G2R A5WM 15G2R MODEL OUTDOOR UNIT A5LC 10CR A5LC 15CR Btu/h 9500 12000 NOMINAL COOLING CAPACITY 2780 3520 Btu/h 9500 12000 NOMINAL HEATING CAPACITY 2780 3520 NOMINAL TOTAL INPUT POWER (COOLING) 1230 NOMINAL TOTAL INPUT POWER (HEATING) 1080 NOMINAL RUNNING CURRENT (COOLING) 3.90 5.40 NOMINAL RUNNING CURRENT (HEATING) 3.40 4.90 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 3.05 2.86...
Page 55
AWM-G2_(i) Engineering & Physical Data General Data - Heat pump (R10A) INDOOR UNIT A5WM 20G2R A5WM 25G2R MODEL OUTDOOR UNIT A5LC 20CR A5LC 25CR Btu/h 17850 / <18000> 20350 / <22500> NOMINAL COOLING CAPACITY- 1Ø / <Ø> 5230 / <5280> 5960 / <6590> Btu/h 18000 / <18500> 22000 / <23000> NOMINAL HEATING CAPACITY- 1Ø / <Ø> 5280 / <5420> 6448 / <6740> NOMINAL TOTAL INPUT POWER (COOLING)- 1Ø / <Ø> 1630 / <1663> 1860 / <2195>...
Page 56
AWM-G2_(i) Engineering & Physical Data General Data - Heat pump (R410A) INDOOR UNIT A5WM 301R MODEL OUTDOOR UNIT A5LC 28CR Btu/h 26000 / <26000> NOMINAL COOLING CAPACITY- 1Ø / <3Ø> 7620 / <7620> Btu/h 26000 / <26000> NOMINAL HEATING CAPACITY- 1Ø / <3Ø> 7620 / <7620>...
AWM-G2_(i) Engineering & Physical Data Component Data - Cooling Only (R22) INDOOR UNIT AWM 0G2 AWM 0G2 MODEL OUTDOOR UNIT ALC 0C ALC 0C TYPE CROSS FLOW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 97 / 3.8 97 / 3.8 LENGTH mm/in 617.5 / 24.3 617.5 / 24.3 TYPE INDUCTION...
Page 58
Engineering & Physical Data AWM-G2_(i) Component Data - Cooling Only (R22) INDOOR UNIT AWM 10G2 AWM 15G2 MODEL OUTDOOR UNIT ALC 10C ALC 15C TYPE CROSS FLOW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 97 / 3.8 97 / 3.8 LENGTH mm/in 717.5 / 28.2 717.5 / 28.2 TYPE INDUCTION...
Page 59
AWM-G2_(i) Engineering & Physical Data Component Data - Cooling Only (R22) INDOOR UNIT AWM 20G2 AWM 20G2 MODEL OUTDOOR UNIT ALC 1C ALC 20C TYPE CROSS FLOW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 108 / 4.25 108 / 4.25 LENGTH mm/in 810 / 31.9 810 / 31.9 TYPE INDUCTION...
Page 60
Engineering & Physical Data AWM-G2_(i) Component Data - Cooling Only (R22) INDOOR UNIT AWM 25G2 AWM 01 MODEL OUTDOOR UNIT ALC 25C ALC 2C TYPE CROSS FLOW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 108 / 4.25 106 / 4.17 LENGTH mm/in 810 / 31.9 950 / 37.4 TYPE INDUCTION...
Page 61
AWM-G2_(i) Engineering & Physical Data Component Data - Heat Pump (R22) INDOOR UNIT AWM 01 MODEL OUTDOOR UNIT ALC 0C TYPE CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIAMETER mm/in 106 / 4.17 LENGTH mm/in 950 / 37.4 TYPE INDUCTION INDOOR FAN MOTOR QUANTITY INDEX OF PROTECTION (IP) IP24 TYPE PROPELLER QUANTITY GLASS REINFORCED ACRYL OUTDOOR FAN MATERIAL STYRENE RESIN...
Page 62
Engineering & Physical Data AWM-G2_(i) Component Data - Heat Pump (R22) INDOOR UNIT AWM 0G2R AWM 10G2R MODEL OUTDOOR UNIT ALC 0CR ALC 10CR TYPE ANTI FUNGUS SKEW FAN ANTI FUNGUS SKEW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 97 / 3.8 97 / 3.8 LENGTH mm/in 617.5 / 24.3 717.5 / 28.2...
Page 63
AWM-G2_(i) Engineering & Physical Data Component Data - Heat Pump (R22) INDOOR UNIT AWM 15G2R AWM 20G2R MODEL OUTDOOR UNIT ALC 15CR ALC 1CR TYPE ANTI FUNGUS SKEW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 97 / 3.8 108 / 4.25 LENGTH mm/in 717.5 / 28.2 810 / 31.9 TYPE...
Page 64
Engineering & Physical Data AWM-G2_(i) Component Data - Heat Pump (R22) INDOOR UNIT AWM 20G2R AWM 25G2R MODEL OUTDOOR UNIT ALC 20CR ALC 25CR TYPE CROSS FLOW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 108 / 4.25 108 / 4.25 LENGTH mm/in 810 / 31.9 810 / 31.9 TYPE INDUCTION...
Page 65
AWM-G2_(i) Engineering & Physical Data Component Data - Heat Pump (R22) INDOOR UNIT AWM 01R AWM 01R MODEL OUTDOOR UNIT ALC 2CR ALC 0CR TYPE ANTI FUNGUS CROSS FLOW FAN ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 106 / 4.17 106 / 4.17 LENGTH mm/in 950 / 37.4...
Page 66
Engineering & Physical Data AWM-G2_(i) Component Data - Cooling Only (R10A) INDOOR UNIT A5WM 0G2 A5WM 0G2 MODEL OUTDOOR UNIT A5LC 0C A5LC 10C TYPE ANTI FUNGUS SKEW FAN ANTI FUNGUS SKEW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 97 / 3.8 97 / 3.8 LENGTH mm/in 617.5 / 24.3 617.5 / 24.3...
Page 67
AWM-G2_(i) Engineering & Physical Data Component Data - Cooling Only (R10A) INDOOR UNIT A5WM 10G2 A5WM 15G2 MODEL OUTDOOR UNIT A5LC 10C A5LC 15C TYPE ANTI FUNGUS SKEW FAN ANTI FUNGUS SKEW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 97 / 3.8 97 / 3.8 LENGTH mm/in 717.5 / 28.2 717.5 / 28.2...
Page 68
Engineering & Physical Data AWM-G2_(i) Component Data - Cooling Only (R10A) INDOOR UNIT A5WM 20G2 A5WM 25G2 MODEL OUTDOOR UNIT A5LC 20C A5LC 25C TYPE ANTI FUNGUS SKEW FAN ANTI FUNGUS SKEW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 108 / 4.25 108 / 4.25 LENGTH mm/in 810 / 31.9 810 / 31.9...
Page 69
AWM-G2_(i) Engineering & Physical Data Component Data - Cooling Only (R10A) INDOOR UNIT A5WM 11 MODEL OUTDOOR UNIT A5LC 2C TYPE ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIAMETER mm/in 106 / 4.17 LENGTH mm/in 950 / 37.4 TYPE INDUCTION INDOOR FAN MOTOR QUANTITY INDEX OF PROTECTION (IP) IP24 TYPE PROPELLER QUANTITY GLASS REINFORCED ACRYL STY- OUTDOOR FAN...
Page 70
Engineering & Physical Data AWM-G2_(i) Component Data - Heat Pump (R10A) INDOOR UNIT A5WM 0G2R A5WM 0G2R MODEL OUTDOOR UNIT A5LC 0CR A5LC 10CR TYPE ANTI FUNGUS SKEW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 97 / 3.8 97 / 3.8 LENGTH mm/in 617.5 / 24.3 617.5 / 24.3 TYPE...
Page 71
AWM-G2_(i) Engineering & Physical Data Component Data - Heat Pump (R10A) INDOOR UNIT A5WM 10G2R A5WM 15G2R MODEL OUTDOOR UNIT A5LC 10CR A5LC 15CR TYPE ANTI FUNGUS SKEW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 97 / 3.8 97 / 3.8 LENGTH mm/in 717.5 / 28.2 717.5 / 28.2 TYPE...
Page 72
Engineering & Physical Data AWM-G2_(i) Component Data - Heat Pump (R10A) INDOOR UNIT A5WM 20G2R A5WM 25G2R MODEL OUTDOOR UNIT A5LC 20CR A5LC 25CR TYPE CROSS FLOW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 108 / 4.25 108 / 4.25 LENGTH mm/in 810 / 31.9 810 / 31.9 TYPE INDUCTION...
Page 73
AWM-G2_(i) Engineering & Physical Data Component Data - Heat Pump (R10A) INDOOR UNIT A5WM 01R MODEL OUTDOOR UNIT A5LC 2CR TYPE ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIAMETER mm/in 106 / 4.17 LENGTH mm/in 950 / 37.4 TYPE INDUCTION INDOOR FAN MOTOR QUANTITY INDEX OF PROTECTION (IP) IP24 TYPE PROPELLER QUANTITY GLASS REINFORCED ACRYL STY- OUTDOOR FAN...
Extrapolation method are not allowed to be used to get the TC, SC and PI Example: Model: AWM 07G2 – ALC 07C Indoor Condition: 25°C DB, 17°C WB Outdoor Condition: 37°C DB...
Page 75
AWM-G2_(i) Performance Data Details: Step: To obtain the Total capacity, Sensible capacity and Power input for (a) Indoor Condition: 25°C DB, 16°C WB Outdoor Condition: 35°C DB Outdoor DB, ˚C Indoor DB Indoor WB ˚C ˚C TC (kW) SHC (kW) PI (kW) 1.87 1.74 0.58 ........... 1.92 1.92 0.58 Total capacity, TC Interpolation Method: 25º...
Page 76
Performance Data AWM-G2_(i) (b) Indoor Condition: 25°C DB, 16°C WB Outdoor Condition: 40°C DB Outdoor DB, ˚C Indoor WB Indoor DB ˚C ˚C TC (kW) SHC (kW) PI (kW) 1.71 1.63 0.63 ........... 1.77 1.77 0.63 Total capacity, TC Interpolation Method: 25º C – 24º C – 1.71kW ⇒ 27º C – 24º C 1.77kW –...
Page 77
AWM-G2_(i) Performance Data Step: To obtain the Total capacity, Sensible capacity and Power input for (a) Indoor Condition: 25°C DB, 17°C WB Outdoor Condition: 35°C DB Outdoor DB, ˚C Indoor WB Indoor DB ˚C ˚C TC (kW) SHC (kW) PI (kW) 1.89 0.58 ........... 2.04 1.45 0.59 Total capacity, TC Interpolation Method: 17º...
Page 78
Performance Data AWM-G2_(i) (b) Indoor Condition: 25°C DB, 17°C WB Outdoor Condition: 40°C DB Outdoor DB, ˚C Indoor WB Indoor DB ˚C ˚C TC (kW) SHC (kW) PI (kW) 1.73 1.68 0.63 ........... 1.87 1.35 0.64 Total capacity, TC Interpolation Method: 17º C – 16º C – 1.73kW ⇒ 18º C – 16º C 1.87kW –...
Page 79
AWM-G2_(i) Performance Data Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 25°C DB, 17°C WB Outdoor Condition: 37°C DB Outdoor DB, ˚C Indoor WB, Indoor DB, ˚C ˚C SHC SHC SHC (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) 1.94 1.68 0.58 1.78 1.24 0.63...
AWM-G2_(i) Outline and Dimension Outline and Dimension Indoor Unit Model: AWM 0G2/0G2/G2R, A5WM 0/0G2/G2R TOP VIEW FRONT VIEW SIDE VIEW INSTALLATION PLATE All dimensions are in mm / (in) Dimension 07/09G2 (31.5) (10.2) (7.8) (15.0) (9.7) (7.3) (4.9) (0.3) (2.2) (2.0) (12.6) (15.0) (2.0) (5.1) (5.2) Outdoor Unit Model: ALC 0C/0C/CR, A5LC 0C/CR Note: Dimension in mm...
Page 136
Outline and Dimension AWM-G2_(i) Indoor Unit Model: AWM 10/15G2/G2R, A5WM 10/15G2/G2R TOP VIEW FRONT VIEW SIDE VIEW INSTALLATION PLATE All dimensions are in mm / (in) All dimensions are in mm / (in) Dimension 10/15G2 (35.4) (10.2) (7.8) (23.2) (9.7) (7.3) (4.9) (0.3) (2.2) (2.0) (16.5) (19.5) (2.0) (5.1) (5.2)
Page 137
AWM-G2_(i) Outline and Dimension Indoor Unit Model: AWM 20/25G2/G2R, A5WM 20/25G2/G2R TOP VIEW FRONT VIEW SIDE VIEW INSTALLATION PLATE All dimensions are in mm / (in) Dimension 1062 20/25G2 (41.8) (12.0) (8.7) (35.9) (11.6) (3.9) (2.0) (0.3) (1.9) (1.7) (13.9) (15.9) (6.3) (5.4) (6.3) Outdoor Unit Model: ALC 1/20/25C/CR, A5LC 20/25C/CR For A5LC / ALC 25C/CR Note : Dimension in mm MODEL ALC 18C/20C/20CR...
Page 138
Outline and Dimension AWM-G2_(i) Indoor Unit Model: AWM 301/301R, A5WM 311/301R Note: Dimension in mm Outdoor Unit Model: A5LC 28C/CR For A5LC / ALC 28 C/CR Only Note : Dimension in mm MODEL ALC 28C/28CR A5LC 28C/28CR Note: Dimension in mm...
Page 139
AWM-G2_(i) Outline and Dimension Indoor Unit Model : AWM 301/301R Note: Dimension in mm Outdoor Unit Model : ALC 30C/CR Note: Dimension in mm...
Electrical Data AWM-G2_(i) Electrical Data Electrical Data - Cooling Only (R22) INDOOR UNIT AWM 0G2 AWM 0G2 MODEL OUTDOOR UNIT ALC 0C ALC 0C INSULATION GRADE CLASS E CLASS E POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.11 0.11 MOTOR OUTPUT POLES INSULATION GRADE CLASS B CLASS B...
Page 141
AWM-G2_(i) Electrical Data Electrical Data - Cooling Only (R22) INDOOR UNIT AWM 10G2 AWM 15G2 MODEL OUTDOOR UNIT ALC 10C ALC 15C INSULATION GRADE CLASS E CLASS E POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.11 0.13 MOTOR OUTPUT POLES INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz...
Page 142
Electrical Data AWM-G2_(i) Electrical Data - Cooling Only (R22) INDOOR UNIT AWM 20G2 AWM 20G2 MODEL OUTDOOR UNIT ALC 1C ALC 20C INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.22 0.22 MOTOR OUTPUT POLES INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz...
Page 143
AWM-G2_(i) Electrical Data Electrical Data - Cooling Only (R22) INDOOR UNIT AWM 25G2 AWM 01 MODEL OUTDOOR UNIT ALC 25C ALC 2C INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.29 0.30 MOTOR OUTPUT POLES INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz...
Page 144
Electrical Data AWM-G2_(i) Electrical Data - Cooling Only (R10A) INDOOR UNIT A5WM 0G2 A5WM 0G2 MODEL OUTDOOR UNIT A5LC 0C A5LC 10C INSULATION GRADE CLASS E CLASS E POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.11 0.11 MOTOR OUTPUT POLES INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz...
Page 145
AWM-G2_(i) Electrical Data Electrical Data - Cooling Only (R10A) INDOOR UNIT A5WM 10G2 A5WM 15G2 MODEL OUTDOOR UNIT A5LC 10C A5LC 15C INSULATION GRADE CLASS E CLASS E POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.11 0.13 MOTOR OUTPUT POLES INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz...
Page 146
Electrical Data AWM-G2_(i) Electrical Data - Cooling Only (R10A) INDOOR UNIT A5WM 20G2 A5WM 25G2 MODEL OUTDOOR UNIT A5LC 20C A5LC 25C INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.22 0.29 MOTOR OUTPUT POLES INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz...
Page 147
AWM-G2_(i) Electrical Data Electrical Data - Cooling Only (R410A) INDOOR UNIT A5WM 311 MODEL OUTDOOR UNIT A5LC 28C INSULATION GRADE CLASS B POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.30 MOTOR OUTPUT IP24...
AWM-G2_(i) Service and Maintenance Service and Maintenance Indoor Models Warning • The unit is designed to give a long life operation with minimum maintenance required. However, it should be regularly checked and the following items should be given due attention. Components Maintenance Procedures Period Air Filter 1.
Page 162
Service and Maintenance AWM-G2_(i) Pre Start Up Maintenance (After Extended Shutdown) • Inspect thoroughly and clean indoor and outdoor units. • Clean or replace air filters. • Clean condensates drain line. • Clean clogged indoor and outdoor coils. • Check fan imbalance before operation. • Tighten all wiring connections and panels. •...
AWM-G2_(i) Troubleshooting Troubleshooting Error Code / Fault Condition When a malfunction of the air conditioner unit is detected, immediately switch off the main power supply before proceeding with the following troubleshooting procedures. The following are common fault conditions and simple troubleshooting tips. If any other fault conditions which are not listed occur, contact your nearest local dealer.
Page 164
Troubleshooting AWM-G2_(i) Diagnostic Guidelines By means of pressure readings: Data Pressure Probable cause Circuit High side 1. Overcharged with refrigerant. • Low side 2. Non-condensable gases in refrigerant circuit (e.g. air) • 3. Obstructed air-intake / discharge. 4. Hot air short circuiting in outdoor unit. High side 1. Poor compression /no compression (compressor •...
Page 165
AWM-G2_(i) Troubleshooting By means of diagnostic flow chart: Generally, there are two kinds of problems, i.e. starting failure and insufficient cooling/heating. “Starting failure” is caused by electrical defect while improper application or defects in refrigerant circuit causes “Insufficient cooling / heating”. i ) Diagnosis of Electric circuit : Faulty : Check...
Page 166
Troubleshooting AWM-G2_(i) Change the contactor Coil burnt Faulty Condenser fan contactor Change the contacts Contact faulty Repair or replace the motor contactor Fan motor faulty Other electrical Repair or change if necessary component faulty Change the contactor Coil burnt Faulty Evaporator contactor Change the contacts...
Page 167
AWM-G2_(i) Troubleshooting ii ) Diagnosis of Refrigerant Circuit / Application There might be some causes where the unit starts running but does not perform satisfactorily, i.e. insufficient cooling. Judgement could be made by measuring temperature difference of indoor unit’s intake and discharge air as well as running current.
Page 168
Troubleshooting AWM-G2_(i) Insufficient heating Indoor/outdoor coil dirty Clean the coil (clogged) Restricted circulation Clean the filter Indoor air filter dirty Change or repair the motor Fan motor malfunction Obstruction at air inlet Remove the obstruction /outlet of indoor / outdoor unit Windows / doors wide High heating...
Page 169
AWM-G2_(i) Troubleshooting Indicator Lights AWM / A5WM - G SERIES IR Signal Receiver When there is infrared remote control operating signal, the signal receiver on indoor unit will made a (beep) for signal acceptance confirmation. Cooling unit / Heatpump unit The table below shows the LED indicator light for air conditioner unit under normal operation and fault condition. The LED indicator lights are located at the middle of the air conditioner unit.
Page 170
Troubleshooting AWM-G2_(i) LED Indicator Lights : Normal Operation and Fault Indication Table Normal Operation / Fault Indication Action COOL/HEAT (GREEN/RED) Cool mode Green Heat mode Auto mode in Heating operation Auto mode in Cooling operation Green Timer on Sleep mode on Ionizer on Fan mode on Dry mode on Room air sensor contact Loose / Short...
Page 171
AWM-G2_(i) Troubleshooting AWM 301 / 301R , A5WM 311 / 301R LED Indicator Lights for Cooling Unit Power On Timer Dry mode Sleep mode LED Indicator Lights : Normal Operation and Fault Conditions for Cooling Unit Normal Operation / Fault Indication Action Power Timer Sleep Timer on Sleep mode on Dry mode on Clean the filter and...
Page 172
Troubleshooting AWM-G2_(i) LED Indicator Lights For Heatpump Unit Cooling mode Dry mode Heat/Fan mode Sleep mode (red/green) LED Indicator Lights : Normal Operation and Fault Conditions for Cooling Unit Normal Operation / Action Fault Indication Cool Heat Sleep Cooling mode Dry mode Fan mode Heat mode Auto mode in heating operation Auto mode in cooling operation Defrost operation Compressor overload protection...
AWM-G2_(i) Exploded View and Part List Exploded View and Part List INDOOR UNIT MODEL: AWM/A5WM 0/0G2/G2R No Description No Description ASSY., CHASIS DRAIN HOSE FAN, MOTOR ASSY., CONTROL BOX CROSS FLOW FAN ASSY., CONTROL BOX COVER FAN, BUSH ASSY., FRONT COVER ASSY., COIL ASSY., AIR DISCHARGE HOUSING PIPING, CLAMP ASSY, MOUNTING PLATE ASSY., DRAIN PAN...
Page 174
AWM-G2_(i) Exploded View and Part List INDOOR UNIT MODEL: AWM/A5WM 10/15G2/G2R No Description No Description ASSY., CHASIS DRAIN HOSE FAN, MOTOR ASSY., CONTROL BOX CROSS FLOW FAN ASSY., CONTROL BOX COVER FAN, BUSH ASSY., FRONT COVER ASSY., COIL ASSY., AIR DISCHARGE HOUSING PIPING, CLAMP ASSY, MOUNTING PLATE ASSY., DRAIN PAN SCREW, S.T.
Page 175
AWM-G2_(i) Exploded View and Part List INDOOR UNIT MODEL: AWM/A5WM 20/25G2/G2R No Description No Description ASSY., CHASIS COVER, PIPING FAN, MOTOR ASSY., CONTROL BOX COVER CROSS FLOW FAN ASSY., FRONT COVER FAN, BUSH SERVICE PANEL ASSY., COIL ASSY., AIR DISCHARGE HOUSING PIPING, CLAMP ASSY, MOUNTING PLATE ASSY., DRAIN PAN SCREW, S.T.
Page 176
AWM-G2_(i) Exploded View and Part List INDOOR UNIT MODEL: AWM 01/01R, A5WM 11/01R No Description No Description Assy. Installation Bracket Handset, Wireless G18 Assy. Chassis Control Box Cover Piping Clamp Assy. Drain Hose Fan Bush Bracket Air Swing Motor Cross Flow Fan Air Louver Fan Bush Assy. Air Discharge Housing Assy.
Page 177
AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: ALC 0C No Description No Description Assy. Base Pan Left Panel Compressor Right Panel Assy. Outdoor Coil Assy. Control Panel Valve Bracket Top/Front Panel Assy. Partition Assy. Valve Cover Assy. Suction Tube Assy. Front Grille Assy. Discharge Tube Parts Not in Diagram Assy.
Page 178
AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: ALC 0C/CR No Description No Description Assy. Base Pan Assy. Control Panel Assy. Outdoor Coil Top/Front Panel Valve Bracket Assy. Valve Cover Compressor Assy. Front Grille Assy. Partition Plastic Handle Assy. Cap Tube Parts Not in Diagram Bracket, Fan Motor Capacitor, Fan Motor Fan Motor Capacitor, Compressor Fan Propeller...
Page 179
AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: ALC 10/15C/CR No Description No Description Assy. Base Pan Top/Front Panel Assy. Outdoor Coil Assy. Front Grille Compressor Fan Propeller Valve Bracket Parts Not in Diagram Assy. Partition Capacitor, Fan Motor Assy. Cap Tube Capacitor, Compressor Left Panel Assy. Flare Valve 2 Ways 1/4” Right Panel Assy.
Page 180
AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: ALC 1/20C/CR No Description No Description Assy. Base Pan Assy. Front Grille Assy. Outdoor Coil Plastic Handle Bracket, Fan Motor Assy. Valve Cover Fan Motor Assy. Cap Tube Fan Propeller Partition Assy. Valve Bracket Parts Not in Diagram Back Panel, Right Capacitor, Fan Motor Compressor Capacitor, Compressor...
Page 181
AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: ALC 25/2C/CR No Description No Description Assy. Base Pan Assy. Control Panel Assy. Outdoor Coil Top Panel Bracket, Fan Motor Assy. Front Grille Fan Motor Plastic Handle Fan Propeller Assy. Valve Cover Assy. Valve Bracket Assy. Cap Tube Back Panel, Right Partition Compressor...
Page 182
AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: ALC 0C/CR No Description No Description Assy. Base Pan Fan Motor Assy. 3 Way VLV 3/8” Fan Blade Assy. 3 Way VLV 5/8” Assy. Front Panel Assy. Panel, Partition Valve Plate Assy. Compressor Parts Not in Diagram Service Panel Capacitor, Compressor Accumulator Capacitor, Fan Motor Panel, Back Right...
Page 183
AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 0C/CR No Description No Description Assy. Base Pan Top/Front Panel Assy. Outdoor Coil Assy. Front Grille Valve Bracket Assy. Valve Cover Compressor Plastic Handle Assy. Partition Assy. 2 Ways Valve 1/4” Assy. Cap Tube Assy. 3 Ways Valve 3/8” Bracket, Fan Motor Parts Not in Diagram Fan Motor...
Page 184
AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 10/15C/CR No Description No Description Assy. Base Pan Assy. Valve Cover Assy. Outdoor Coil Assy. Front Grille Valve Bracket Plastic Handle Compressor Assy. 2 Ways Valve 1/4” Assy. Partition Assy. 3 Ways Valve 3/8” Assy. Cap Tube A5LC 10C/CR Bracket, Fan Motor Assy.
Page 185
AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 20C/CR No Description No Description Assy. Base Pan Top Panel Assy. Outdoor Coil Assy. Front Grille Bracket, Fan Motor Plastic Handle Fan Motor Assy. Valve Cover Fan Propeller Assy. Cap Tube Assy. Valve Bracket Partition Assy. 3 Ways Valve 1/2” Parts Not in Diagram Assy.
Page 186
AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 25/2C/CR No Description No Description Assy. Base Pan Terminal Cover Panel Assy. Outdoor Coil Assy. Control Panel Bracket, Fan Motor Top Panel Fan Motor Assy. Front Grille Fan Propeller Plastic Handle Assy. Valve Bracket Assy. Valve Cover Assy.
Page 187
AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 20C/CR ( phase) No Description No Description Assy. Base Pan Top Panel Assy. Outdoor Coil Assy. Front Grille Bracket, Fan Motor Plastic Handle Fan Motor Assy. Valve Cover Fan Propeller Assy. Cap Tube Assy. Valve Bracket Partition Assy. 3 Ways Valve 1/2” Parts Not in Diagram Assy.
Page 188
AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 25/2C/CR ( phase) No Description No Description Assy. Base Pan Service Panel Assy. Outdoor Coil Assy. Control Panel Bracket, Fan Motor Top Panel Fan Motor Assy. Front Grille Fan Propeller Plastic Handle Assy. Valve Bracket Assy. Valve Cover Assy. 3 Ways Valve 5/8” Assy.
Page 190
While upmost care is taken in ensuring that all details in the publication are correct at time of going to press, we are constantly striving for improvement and therefore reserve the rights to alter model specifications and equipment without prior notice. Details of speci fications andequipment are also subject to change to suit local conditions and equirements and not all models are available in every market.