Acson AWM 07G2 User Manual

Acson AWM 07G2 User Manual

Wall mounted split systems

Advertisement

Models:
AWM 07G2
AWM 09G2/G2R
AWM 10G2/G2R
AWM 152G/G2R
AWM 20G2/G2R
AWM 25G2/G2R
AWM 301/301R
A5WM 07G2/G2R
A5WM 09G2/G2R
A5WM 10G2/G2R
A5WM 15G2/G2R
A5WM 20G2/G2R
A5WM 25G2/G2R
A5WM 311/301R
Wall Mounted Split Systems
AWM-G2_(i)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AWM 07G2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Acson AWM 07G2

  • Page 1 Models: AWM 07G2 AWM 09G2/G2R AWM 10G2/G2R AWM 152G/G2R AWM 20G2/G2R AWM 25G2/G2R AWM 301/301R A5WM 07G2/G2R A5WM 09G2/G2R A5WM 10G2/G2R A5WM 15G2/G2R A5WM 20G2/G2R A5WM 25G2/G2R A5WM 311/301R Wall Mounted Split Systems AWM-G2_(i)
  • Page 2: Table Of Contents

    AWM-G2_(i) Table of Contents Table of Contents Nomenclature........................1 Indoor Unit ........................1 Outdoor Unit ........................2 Product Line-Up ........................3 Features..........................9 Application Information ....................10 Operating Range ......................10 Refrigerant Circuit Diagram ..................11 Controller ........................19 Installation Guideline ....................20 Sound Data ........................34 Sound Pressure Level ....................34 NC Curve ........................35 Engineering & Physical Data ...................38 General Data .......................38 Components Data ......................55 Performance Data ......................72...
  • Page 3: Nomenclature

    Nomenclature AWM-G2_(i) Nomenclature Indoor Unit Brand : Acson Refrigerant “ “ : Omitted if R22 : R407C : R410A Model Name : Wall Mounted Capacity Index : 10,000 Btu/h : 20,000 Btu/h Chassis : G + Series Model Type “ “...
  • Page 4: Outdoor Unit

    Nomenclature AWM-G2_(i) Outdoor Unit Brand : Acson Refrigerant “ “ : Omitted if R22 : R407C : R410A Model Name : Single Split Condensing Unit Capacity Index : 10,000 Btu/h : 20,000 Btu/h Chassis : C Series Model Type “ “...
  • Page 5: Product Line-Up

    Product Line-Up AWM-G2_(i) Product Line-Up Indoor Unit AWM-G2 Series Classification 07G2 ACICE 09G2 ACICE 10G2 ACICE 15G2 ACICE 20G2 ACICE 25G2 ACICE AFBF 09G2R ACICE 10G2R ACICE 15G2R ACICE 20G2R ACICE 25G2R ACICE 301R AFAE...
  • Page 6 AWM-G2_(i) Product Line-Up Indoor Unit A5WM-G2 Series Classifi cation A5WM 07G2 ACICE 09G2 ACICE 10G2 ACICE 15G2 ACICE 20G2 ACICE 25G2 ACICE AFCE 07G2R ACICE 09G2R ACICE 10G2R ACICE 15G2R ACICE 20G2R ACICE 25G2R ACICE 301R AFCE...
  • Page 7 Product Line-Up AWM-G2_(i) Outdoor Unit ALC-C Series Classification ACPOE ACPIE ACPOD ACPID ACPOB ACPIB ACPOD ACPID ACPOD ACPID ACPBD ACPOD ACPID ACPBD ACPHB ACPOD ACPID ACPBD ACPHB ACHOB ACHIB ACHBB AFGE...
  • Page 8 Product Line-Up AWM-G2_(i) Outdoor Unit ALC-C Series Classification ACPOD 09CR ACPID ACPOB 10CR ACPIB ACPOA 15CR ACPIA ACPOD 18CR ACPID ACPOD ACPID 20CR ACPHB ACPOD ACPID 25CR ACHIB ACHOB 28CR ACHIB AFFB 30CR...
  • Page 9 Product Line-Up AWM-G2_(i) Outdoor Unit A5LC-C Series Classification A5LC ACPOE ACPIE ACPOB ACPIB ACPOC ACPIC ACPOC ACPIC ACPGC FCPOC FCPGC ACPOC ACPIC ACPGC FCPOC FCPGC ACPOA ACPIA ACPGA FCPOA FCPGA...
  • Page 10 Product Line-Up AWM-G2_(i) Outdoor Unit A5LC-C Series Classification A5LC ACPOE 07CR ACPIE ACPOB 10CR ACPIB ACPOC 15CR ACPIC ACPOC ACPIC 20CR FCPOC ACPOC ACPIC 25CR FCPOC ACPOA ACPIA 28CR FCPOA...
  • Page 11: Features

    Features AWM-G2_(i) Features Excellent Air Distribution Air discharge direction can be adjusted in four directions, manually or automatically by using LCD remote control. The new double louver design with automatic air swing function fully optimizes the room comfort by distributing the air evenly to the room. The unique skew fan design with larger diameter creates better air flow to the operating environment.
  • Page 12: Application Information

    Application Information AWM-G2_(i) Application Information Operating Range Ensure the operating temperature is in allowable range. Cooling only Standard point Caution : The use of your air conditioner outside the range of working Low ambient kit temperature and humidity can result in serious failure. Indoor temp.
  • Page 13: Refrigerant Circuit Diagram

    AWM-G2_(i) Application Information Refrigerant Circuit Diagram Model: AWM 0G2 - ALC 0C A5WM 0G2 - A5LC 0C AWM 0G2 - ALC 0C A5WM 0G2 - A5LC 0C AWM 10G2 - ALC 10C A5WM 10G2 - A5LC 10C AWM 15G2 - ALC 15C A5WM 15G2 - A5LC 15C Model: AWM 20G2 - ALC 1C A5WM 20G2 - A5LC 20C AWM 20G2 - ALC 20C A5WM 25G2 - A5LC 25C...
  • Page 14 Application Information AWM-G2_(i) Model: AWM 25G2 - ALC 25C A5WM 11 - A5LC 2C Model: AWM 01 - ALC 2C...
  • Page 15 AWM-G2_(i) Application Information Model: AWM 01 – ALC 0C...
  • Page 16 Application Information AWM-G2_(i) Model: A5WM 20/25G2 - A5LC 20/25C (With Low Ambient Kit) A5WM 01 - A5LC 2C (With Low Ambient Kit)
  • Page 17 AWM-G2_(i) Application Information Model: AWM 0G2R - ALC 0CR A5WM 0G2R - A5LC 0CR Model: AWM 10G2R - ALC 10CR A5WM 0G2R - A5LC 10CR A5WM 10G2R - A5LC 10CR...
  • Page 18 Application Information AWM-G2_(i) Model: AWM 15G2R - ALC 15CR A5WM 15G2R - A5LC 15CR Model: AWM 20G2R - ALC 20CR A5WM 20G2R - A5LC 20CR A5WM 25G2R - A5LC 25CR...
  • Page 19 AWM-G2_(i) Application Information Model: AWM 25G2R - ALC 25CR Model: AWM 01R - ALC 2CR A5WM 01R - A5LC 2CR...
  • Page 20 Application Information AWM-G2_(i) Model: AWM 01R – ALC 0CR...
  • Page 21: Controller

    AWM-G2_(i) Application Information Controller SLEEP MODE TIMER TIMER TIMER CANCEL Operation Guide Transmission Source Operating Mode • The source where the signal will be transmitted. • Press the MODE button to select the type of operating mode. Signal Transmission Indication • For cooling only unit, the available modes are: COOL (  ), •...
  • Page 22: Installation Guideline

    Application Information AWM-G2_(i) Installation Guideline Safety Precautions WARNING CAUTION Please take note of the following important points • Installation and maintenance should be performed by when installing. qualified persons who are familiar with local code and • Do not install the unit where leakage of flammable regulation, and experienced with this type of appliance.
  • Page 23 AWM-G2_(i) Application Information Installation Diagram Indoor Unit Air Filter Front Frame Back Housing Air Intake ON/OFF Switch Grille Indicator Light Drain Hose Signal Receiver Air Intake Air Discharge Refrigerant Piping Nozzle Outdoor Unit Caution • Before installing the unit, ensure that the power supply matches the power requirement of the airconditioner.
  • Page 24: Air Flow

    Application Information AWM-G2_(i) Selection of Location and Space Indoor Unit Install the fan coil (indoor) unit at a location with the following requirements • Location is suitable for wiring, piping and drainage. • No obstruction of air flow into and out of unit where cooler air can be evenly distributed.(See fig. 1) •...
  • Page 25 AWM-G2_(i) Application Information Outdoor Unit As condensing temperature rises, evaporating temperature rises and cooling capacity drops. In order to achieve maximum cooling capacity, the location selected for outdoor unit should fulfill the following requirements : • Install the condensing (outdoor) unit in a way such that hot air distributed by the outdoor condensing unit cannot bedrawn in again (as in the case of short circuit of hot discharge air).
  • Page 26 Application Information AWM-G2_(i) Installation of Outdoor Unit Condensed Water Disposal of Outdoor Unit (Heat Pump Unit Only) • There are 2 holes on the base of outdoor unit for condensed water to flow out. Insert the drain elbow toone of the holes. • To install the drain elbow, first insert one portion of the hook to the base (portion A), then pull the drainelbow in the direction shown by the arrow while inserting the other portion to the base.
  • Page 27 AWM-G2_(i) Application Information Drilling Holes and Mounting Installation Installation Plate Caution • Please check the unit weight for each model. Always ensure that the wall is sufficiently strong to withstandthe weight. If not, it is necessary to reinforce the wall with plate, beams or pillars. • The unit cannot be directly fixed onto the wall or the likes. In all cases, the installation plate provided MUST be used. •...
  • Page 28 Application Information AWM-G2_(i) • Fixing method:- REINFORCED CONCRETE BUILDING WOODENFRAME WALL NUT ANCHOR BOLT ANCHOR Indoor Unit Preparation • The refrigerant piping can be routed to the unit in 5 direction, by using the cut outs in the unit casing. (See fig. 1) •...
  • Page 29: Refrigerant Piping

    AWM-G2_(i) Application Information Wiring Electrical Connection • Wiring regulation on wire diameters differ from country to country. Please refer to your LOCAL ELECTRICAL CODES for fi eld wiring rules. Be sure that installation comply with such rules and regulations. General Precautions •...
  • Page 30 Application Information AWM-G2_(i) • The exact length of pipe protruding from the face of the flare die is determined by the flaring tool. The table shows the use of an imperial die and riged die. A(mm) PIPE Ø, D (mm) IMPERIAL DIE RIGED DIE 6.35 (1/4”) 9.52 (3/8”)
  • Page 31 AWM-G2_(i) Application Information ii) Outdoor Installation Space Is Limited • If the orifice pipe can not be connected directly to the liquid valve due tolimitation space, it can be Step 4 connected between the liquid pipes. Orifice Pipe Step 3 Step 2 Step 1 •...
  • Page 32 Application Information AWM-G2_(i) VACUUMING AND CHARGING • The precharged outdoor unit does not need any vacuuming or charging. However once it is connected, the connecting pipe line and the indoor need to be vacuumed before releasing the R22/R407C/R410A from the outdoor unit. 1) Open the service port core cap. 2) Connect pressure gauge to the service port.
  • Page 33 • When the piping length is more than 7.6m, please use the table below : Additional charge in gram. R22 MODELS AWM 07G2 / 09G2 / 10G2 / 15G2 AWM 20G2 AWM 25G2 AWM 301 1030...
  • Page 34 Application Information AWM-G2_(i) Diagram shows typical charging method. Caution For R10A • Avoid prolong exposure of an opened compressor, or the internal part of refrigerant piping to moist air. The POE oil in the compressor and piping can absorb moisture from air. Final Checking •...
  • Page 35 AWM-G2_(i) Application Information ) CHARACTERISTIC • R410A liquid and vapor components have different compositions when the fluid evaporates or condenses. Hence, when leak occurs and only vapor leaks out, the composition of the refrigerant mixture left in the system will change and subsequently affect the system performance. DO NOT add new refrigerant to leaked system.
  • Page 36: Sound Data

    Sound Data AWM-G2_(i) Sound Data Sound Pressure Level 1/1 Octave Sound Pressure Level (dB, ref 20µPa) Speed Overall Noise Model (RPM) (dBA) Criteria 125 Hz 250 Hz 500 Hz 1k Hz 2k Hz k Hz k Hz High AWM 0G2 AWM 0G2/G2R Medium A5WM 0G2/G2R A5WM 0G2/G2R High AWM 10G2/G2R Medium A5WM 10G2/G2R High AWM 15G2/G2R Medium A5WM 15G2/G2R High AWM 20G2/G2R Medium A5WM 20G2/G2R High AWM 25G2/G2R Medium A5WM 25G2/G2R High...
  • Page 37: Nc Curve

    AWM-G2_(i) Sound Data AWM 07/09G2/G2R , A5WM 07/09G2/G2R NC CURVES NC-45 NC-40 High Fan NC-35 Medium Fan NC-30 Low Fan NC-25 NC-20 1000 2000 4000 8000 Octave-band frequency (Hz) AWM 10G2/G2R , A5WM 10G2/G2R NC CURVES NC-45 NC-40 High Fan Medium Fan NC-35 NC-30 Low Fan...
  • Page 38 Sound Data AWM-G2_(i) AWM 15G2/G2R , A5WM 15G2/G2R NC CURVES NC-45 NC-40 High Fan NC-35 Medium Fan NC-30 NC-25 NC-20 Low Fan 1000 2000 4000 8000 Octave-band frequency (Hz) AWM 20G2/G2R , A5WM 20G2/G2R NC CURVES High Fan NC-45 Medium Fan NC-40 Low Fan NC-35...
  • Page 39 AWM-G2_(i) Sound Data AWM 25G2/G2R , A5WM 25G2/G2R NC CURVES High Fan Medium Fan NC-45 Low Fan NC-40 NC-35 NC-30 NC-25 NC-20 1000 2000 4000 8000 Octave-band frequency (Hz) AWM 301/301R , A5WM 311/301R NC CURVES NC-50 NC-45 High Fan NC-40 Medium Fan Low Fan NC-35...
  • Page 40: Engineering & Physical Data

    Engineering & Physical Data AWM-G2_(i) Engineering & Physical Data General Data - Cooling Only (R22) INDOOR UNIT AWM 0G2 AWM 0G2 MODEL OUTDOOR UNIT ALC 0C ALC 0C Btu/h 7000 9000 NOMINAL CAPACITY 2050 2640 NOMINAL TOTAL INPUT POWER NOMINAL RUNNING CURRENT 2.70 4.10 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 3.47 2.87 REFRIGERANT TYPE...
  • Page 41 AWM-G2_(i) Engineering & Physical Data General Data - Cooling Only (R22) INDOOR UNIT AWM 10G2 AWM 15G2 MODEL OUTDOOR UNIT ALC 10C ALC 15C Btu/h 9500 12000 NOMINAL CAPACITY 2780 3520 NOMINAL TOTAL INPUT POWER 1200 NOMINAL RUNNING CURRENT 3.80 5.40 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 3.23 2.93 REFRIGERANT TYPE REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR CAP.
  • Page 42 Engineering & Physical Data AWM-G2_(i) General Data - Cooling Only (R22) INDOOR UNIT AWM 20G2 AWM 20G2 MODEL OUTDOOR UNIT ALC 1C ALC 20C Btu/h 18000 19000 NOMINAL CAPACITY 5280 5570 NOMINAL TOTAL INPUT POWER 1820 1807 NOMINAL RUNNING CURRENT 8.10 8.00 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 2.90 3.08 REFRIGERANT TYPE REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR CAP.
  • Page 43 AWM-G2_(i) Engineering & Physical Data General Data - Cooling Only (R22) INDOOR UNIT AWM 25G2 AWM 01 MODEL OUTDOOR UNIT ALC 25C ALC 2C Btu/h 23500 27000 NOMINAL CAPACITY 6890 7913 NOMINAL TOTAL INPUT POWER 2530 2708 NOMINAL RUNNING CURRENT 11.30 13.10 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 2.72 3.00 REFRIGERANT TYPE REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR CAP.
  • Page 44 Engineering & Physical Data AWM-G2_(i) General Data - Cooling Only (R22) INDOOR UNIT AWM 01 MODEL OUTDOOR UNIT ALC 0C Btu/h 30000 NOMINAL CAPACITY 8790 NOMINAL TOTAL INPUT POWER 2944 NOMINAL RUNNING CURRENT 12.60 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 2.99 REFRIGERANT TYPE REFRIGERANT CONTROL (EXPANSION DEVICE) EXTERNAL ORIFICE KIT AUTO LOUVER (UP & DOWN) & AIR DISCHARGE GRILLE (LEFT & RIGHT) CONTROL OPERATION LCD REMOTE CONTROL...
  • Page 45 AWM-G2_(i) Engineering & Physical Data General Data - Heat pump (R22) INDOOR UNIT AWM 0G2R AWM 10G2R MODEL OUTDOOR UNIT ALC 0CR ALC 10CR Btu/h 8800 9500 NOMINAL COOLING CAPACITY 2580 2780 Btu/h 8600 9500 NOMINAL HEATING CAPACITY 2520 2780 NOMINAL TOTAL INPUT POWER (COOLING) NOMINAL TOTAL INPUT POWER (HEATING) NOMINAL RUNNING CURRENT (COOLING) 4.00 3.80 NOMINAL RUNNING CURRENT (HEATING) 3.40 3.40 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 2.84 3.23 3.36...
  • Page 46 Engineering & Physical Data AWM-G2_(i) General Data - Heat pump (R22) INDOOR UNIT AWM 15G2R AWM 20G2R MODEL OUTDOOR UNIT ALC 15CR ALC 1CR Btu/h 12000 18000 NOMINAL COOLING CAPACITY 3520 5280 Btu/h 12000 18400 NOMINAL HEATING CAPACITY 3520 5390 NOMINAL TOTAL INPUT POWER (COOLING) 1100 1820 NOMINAL TOTAL INPUT POWER (HEATING) 1660 NOMINAL RUNNING CURRENT (COOLING) 5.00 8.10 NOMINAL RUNNING CURRENT (HEATING) 4.50 7.40 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 3.20 2.90...
  • Page 47 AWM-G2_(i) Engineering & Physical Data General Data - Heat pump (R22) INDOOR UNIT AWM 20G2R AWM 25G2R MODEL OUTDOOR UNIT ALC 20CR ALC 25CR Btu/h 19000 23500 NOMINAL COOLING CAPACITY 5570 6890 Btu/h 19500 24000 NOMINAL HEATING CAPACITY 5720 7030 NOMINAL TOTAL INPUT POWER (COOLING) 1807 2530 NOMINAL TOTAL INPUT POWER (HEATING) 1757 2450 NOMINAL RUNNING CURRENT (COOLING) 8.00 11.30 NOMINAL RUNNING CURRENT (HEATING) 7.80 11.10 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 3.08 2.72...
  • Page 48 Engineering & Physical Data AWM-G2_(i) General Data - Heat pump (R22) INDOOR UNIT AWM 01R AWM 01R MODEL OUTDOOR UNIT ALC 2CR ALC 0CR Btu/h 27000 30000 NOMINAL COOLING CAPACITY 7913 8790 Btu/h 27000 30000 NOMINAL HEATING CAPACITY 7913 8790 NOMINAL TOTAL INPUT POWER (COOLING) 2708 2944 NOMINAL TOTAL INPUT POWER (HEATING) 2273 2864 NOMINAL RUNNING CURRENT (COOLING) 13.20 14.30 NOMINAL RUNNING CURRENT (HEATING) 13.30 13.70 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 2.92 2.99...
  • Page 49 AWM-G2_(i) Engineering & Physical Data General Data - Cooling Only (R22) INDOOR UNIT A5WM 0G2 A5WM 0G2 MODEL OUTDOOR UNIT A5LC 0C A5LC 10C Btu/h 7500 9000 NOMINAL CAPACITY 2200 2640 NOMINAL TOTAL INPUT POWER NOMINAL RUNNING CURRENT 2.90 3.90 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 3.55 3.07 REFRIGERANT TYPE R410A R410A REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR CAP.
  • Page 50 Engineering & Physical Data AWM-G2_(i) General Data - Cooling Only (R10A) INDOOR UNIT A5WM 10G2 A5WM 15G2 MODEL OUTDOOR UNIT A5LC 10C A5LC 15C Btu/h 9500 12000 NOMINAL CAPACITY 2780 3520 NOMINAL TOTAL INPUT POWER 1230 NOMINAL RUNNING CURRENT 3.90 5.40 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 3.05 2.86 REFRIGERANT TYPE R410A R410A REFRIGERANT CONTROL (EXPANSION DEVICE)
  • Page 51 AWM-G2_(i) Engineering & Physical Data General Data - Cooling Only (R10A) INDOOR UNIT A5WM 20G2 A5WM 25G2 MODEL OUTDOOR UNIT A5LC 20C A5LC 25C Btu/h 17850 / <18000> 20350 / <22500> NOMINAL CAPACITY-1Ø/ <Ø> 5230 / <5280> 5960 / <6590> NOMINAL TOTAL INPUT POWER-1Ø/ <Ø> 1630 / <1663> 1860 / <2195> NOMINAL RUNNING CURRENT-1Ø/ <Ø> 7.3 / <3.2> 8.4 / <4.2> POWER SOURCE-1Ø/ <Ø> V/Ph/Hz 220-240/ 1/ 50 / <380-415/ 3/ 50>...
  • Page 52 Engineering & Physical Data AWM-G2_(i) General Data - Cooling Only (R10A) INDOOR UNIT A5WM 11 MODEL OUTDOOR UNIT A5LC 2C Btu/h 26000 / <26000> NOMINAL CAPACITY-1Ø/ <Ø> 7620 / <7620> NOMINAL TOTAL INPUT POWER-1Ø/ <Ø> 2560 / <2631> NOMINAL RUNNING CURRENT-1Ø/ <Ø> 12.2 / <4.6> POWER SOURCE-1Ø/ <Ø> V/Ph/Hz 220-240/ 1/ 50 / <380-415/ 3/ 50> EER-1Ø/ <Ø> 2.98 / <2.90> REFRIGERANT TYPE R410A REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR CAP.
  • Page 53 AWM-G2_(i) Engineering & Physical Data General Data - Heat pump (R10A) INDOOR UNIT A5WM 0G2R A5WM 0G2R MODEL OUTDOOR UNIT A5LC 0CR A5LC 10CR Btu/h 7500 9000 NOMINAL COOLING CAPACITY 2200 2640 Btu/h 7500 9000 NOMINAL HEATING CAPACITY 2200 2640 NOMINAL TOTAL INPUT POWER (COOLING) NOMINAL TOTAL INPUT POWER (HEATING) NOMINAL RUNNING CURRENT (COOLING) 3.10 3.90 NOMINAL RUNNING CURRENT (HEATING) 2.60 3.40 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 3.24 3.07 4.00...
  • Page 54 Engineering & Physical Data AWM-G2_(i) General Data - Heat pump (R10A) INDOOR UNIT A5WM 10G2R A5WM 15G2R MODEL OUTDOOR UNIT A5LC 10CR A5LC 15CR Btu/h 9500 12000 NOMINAL COOLING CAPACITY 2780 3520 Btu/h 9500 12000 NOMINAL HEATING CAPACITY 2780 3520 NOMINAL TOTAL INPUT POWER (COOLING) 1230 NOMINAL TOTAL INPUT POWER (HEATING) 1080 NOMINAL RUNNING CURRENT (COOLING) 3.90 5.40 NOMINAL RUNNING CURRENT (HEATING) 3.40 4.90 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 3.05 2.86...
  • Page 55 AWM-G2_(i) Engineering & Physical Data General Data - Heat pump (R10A) INDOOR UNIT A5WM 20G2R A5WM 25G2R MODEL OUTDOOR UNIT A5LC 20CR A5LC 25CR Btu/h 17850 / <18000> 20350 / <22500> NOMINAL COOLING CAPACITY- 1Ø / <Ø> 5230 / <5280> 5960 / <6590> Btu/h 18000 / <18500> 22000 / <23000> NOMINAL HEATING CAPACITY- 1Ø / <Ø> 5280 / <5420> 6448 / <6740> NOMINAL TOTAL INPUT POWER (COOLING)- 1Ø / <Ø> 1630 / <1663> 1860 / <2195>...
  • Page 56 AWM-G2_(i) Engineering & Physical Data General Data - Heat pump (R410A) INDOOR UNIT A5WM 301R MODEL OUTDOOR UNIT A5LC 28CR Btu/h 26000 / <26000> NOMINAL COOLING CAPACITY- 1Ø / <3Ø> 7620 / <7620> Btu/h 26000 / <26000> NOMINAL HEATING CAPACITY- 1Ø / <3Ø> 7620 / <7620>...
  • Page 57: Components Data

    AWM-G2_(i) Engineering & Physical Data Component Data - Cooling Only (R22) INDOOR UNIT AWM 0G2 AWM 0G2 MODEL OUTDOOR UNIT ALC 0C ALC 0C TYPE CROSS FLOW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 97 / 3.8 97 / 3.8 LENGTH mm/in 617.5 / 24.3 617.5 / 24.3 TYPE INDUCTION...
  • Page 58 Engineering & Physical Data AWM-G2_(i) Component Data - Cooling Only (R22) INDOOR UNIT AWM 10G2 AWM 15G2 MODEL OUTDOOR UNIT ALC 10C ALC 15C TYPE CROSS FLOW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 97 / 3.8 97 / 3.8 LENGTH mm/in 717.5 / 28.2 717.5 / 28.2 TYPE INDUCTION...
  • Page 59 AWM-G2_(i) Engineering & Physical Data Component Data - Cooling Only (R22) INDOOR UNIT AWM 20G2 AWM 20G2 MODEL OUTDOOR UNIT ALC 1C ALC 20C TYPE CROSS FLOW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 108 / 4.25 108 / 4.25 LENGTH mm/in 810 / 31.9 810 / 31.9 TYPE INDUCTION...
  • Page 60 Engineering & Physical Data AWM-G2_(i) Component Data - Cooling Only (R22) INDOOR UNIT AWM 25G2 AWM 01 MODEL OUTDOOR UNIT ALC 25C ALC 2C TYPE CROSS FLOW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 108 / 4.25 106 / 4.17 LENGTH mm/in 810 / 31.9 950 / 37.4 TYPE INDUCTION...
  • Page 61 AWM-G2_(i) Engineering & Physical Data Component Data - Heat Pump (R22) INDOOR UNIT AWM 01 MODEL OUTDOOR UNIT ALC 0C TYPE CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIAMETER mm/in 106 / 4.17 LENGTH mm/in 950 / 37.4 TYPE INDUCTION INDOOR FAN MOTOR QUANTITY INDEX OF PROTECTION (IP) IP24 TYPE PROPELLER QUANTITY GLASS REINFORCED ACRYL OUTDOOR FAN MATERIAL STYRENE RESIN...
  • Page 62 Engineering & Physical Data AWM-G2_(i) Component Data - Heat Pump (R22) INDOOR UNIT AWM 0G2R AWM 10G2R MODEL OUTDOOR UNIT ALC 0CR ALC 10CR TYPE ANTI FUNGUS SKEW FAN ANTI FUNGUS SKEW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 97 / 3.8 97 / 3.8 LENGTH mm/in 617.5 / 24.3 717.5 / 28.2...
  • Page 63 AWM-G2_(i) Engineering & Physical Data Component Data - Heat Pump (R22) INDOOR UNIT AWM 15G2R AWM 20G2R MODEL OUTDOOR UNIT ALC 15CR ALC 1CR TYPE ANTI FUNGUS SKEW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 97 / 3.8 108 / 4.25 LENGTH mm/in 717.5 / 28.2 810 / 31.9 TYPE...
  • Page 64 Engineering & Physical Data AWM-G2_(i) Component Data - Heat Pump (R22) INDOOR UNIT AWM 20G2R AWM 25G2R MODEL OUTDOOR UNIT ALC 20CR ALC 25CR TYPE CROSS FLOW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 108 / 4.25 108 / 4.25 LENGTH mm/in 810 / 31.9 810 / 31.9 TYPE INDUCTION...
  • Page 65 AWM-G2_(i) Engineering & Physical Data Component Data - Heat Pump (R22) INDOOR UNIT AWM 01R AWM 01R MODEL OUTDOOR UNIT ALC 2CR ALC 0CR TYPE ANTI FUNGUS CROSS FLOW FAN ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 106 / 4.17 106 / 4.17 LENGTH mm/in 950 / 37.4...
  • Page 66 Engineering & Physical Data AWM-G2_(i) Component Data - Cooling Only (R10A) INDOOR UNIT A5WM 0G2 A5WM 0G2 MODEL OUTDOOR UNIT A5LC 0C A5LC 10C TYPE ANTI FUNGUS SKEW FAN ANTI FUNGUS SKEW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 97 / 3.8 97 / 3.8 LENGTH mm/in 617.5 / 24.3 617.5 / 24.3...
  • Page 67 AWM-G2_(i) Engineering & Physical Data Component Data - Cooling Only (R10A) INDOOR UNIT A5WM 10G2 A5WM 15G2 MODEL OUTDOOR UNIT A5LC 10C A5LC 15C TYPE ANTI FUNGUS SKEW FAN ANTI FUNGUS SKEW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 97 / 3.8 97 / 3.8 LENGTH mm/in 717.5 / 28.2 717.5 / 28.2...
  • Page 68 Engineering & Physical Data AWM-G2_(i) Component Data - Cooling Only (R10A) INDOOR UNIT A5WM 20G2 A5WM 25G2 MODEL OUTDOOR UNIT A5LC 20C A5LC 25C TYPE ANTI FUNGUS SKEW FAN ANTI FUNGUS SKEW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 108 / 4.25 108 / 4.25 LENGTH mm/in 810 / 31.9 810 / 31.9...
  • Page 69 AWM-G2_(i) Engineering & Physical Data Component Data - Cooling Only (R10A) INDOOR UNIT A5WM 11 MODEL OUTDOOR UNIT A5LC 2C TYPE ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIAMETER mm/in 106 / 4.17 LENGTH mm/in 950 / 37.4 TYPE INDUCTION INDOOR FAN MOTOR QUANTITY INDEX OF PROTECTION (IP) IP24 TYPE PROPELLER QUANTITY GLASS REINFORCED ACRYL STY- OUTDOOR FAN...
  • Page 70 Engineering & Physical Data AWM-G2_(i) Component Data - Heat Pump (R10A) INDOOR UNIT A5WM 0G2R A5WM 0G2R MODEL OUTDOOR UNIT A5LC 0CR A5LC 10CR TYPE ANTI FUNGUS SKEW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 97 / 3.8 97 / 3.8 LENGTH mm/in 617.5 / 24.3 617.5 / 24.3 TYPE...
  • Page 71 AWM-G2_(i) Engineering & Physical Data Component Data - Heat Pump (R10A) INDOOR UNIT A5WM 10G2R A5WM 15G2R MODEL OUTDOOR UNIT A5LC 10CR A5LC 15CR TYPE ANTI FUNGUS SKEW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 97 / 3.8 97 / 3.8 LENGTH mm/in 717.5 / 28.2 717.5 / 28.2 TYPE...
  • Page 72 Engineering & Physical Data AWM-G2_(i) Component Data - Heat Pump (R10A) INDOOR UNIT A5WM 20G2R A5WM 25G2R MODEL OUTDOOR UNIT A5LC 20CR A5LC 25CR TYPE CROSS FLOW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 108 / 4.25 108 / 4.25 LENGTH mm/in 810 / 31.9 810 / 31.9 TYPE INDUCTION...
  • Page 73 AWM-G2_(i) Engineering & Physical Data Component Data - Heat Pump (R10A) INDOOR UNIT A5WM 01R MODEL OUTDOOR UNIT A5LC 2CR TYPE ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIAMETER mm/in 106 / 4.17 LENGTH mm/in 950 / 37.4 TYPE INDUCTION INDOOR FAN MOTOR QUANTITY INDEX OF PROTECTION (IP) IP24 TYPE PROPELLER QUANTITY GLASS REINFORCED ACRYL STY- OUTDOOR FAN...
  • Page 74: Performance Data

    Extrapolation method are not allowed to be used to get the TC, SC and PI Example: Model: AWM 07G2 – ALC 07C Indoor Condition: 25°C DB, 17°C WB Outdoor Condition: 37°C DB...
  • Page 75 AWM-G2_(i) Performance Data Details: Step: To obtain the Total capacity, Sensible capacity and Power input for (a) Indoor Condition: 25°C DB, 16°C WB Outdoor Condition: 35°C DB Outdoor DB, ˚C Indoor DB Indoor WB ˚C ˚C TC (kW) SHC (kW) PI (kW) 1.87 1.74 0.58 ........... 1.92 1.92 0.58 Total capacity, TC Interpolation Method: 25º...
  • Page 76 Performance Data AWM-G2_(i) (b) Indoor Condition: 25°C DB, 16°C WB Outdoor Condition: 40°C DB Outdoor DB, ˚C Indoor WB Indoor DB ˚C ˚C TC (kW) SHC (kW) PI (kW) 1.71 1.63 0.63 ........... 1.77 1.77 0.63 Total capacity, TC Interpolation Method: 25º C – 24º C – 1.71kW ⇒ 27º C – 24º C 1.77kW –...
  • Page 77 AWM-G2_(i) Performance Data Step: To obtain the Total capacity, Sensible capacity and Power input for (a) Indoor Condition: 25°C DB, 17°C WB Outdoor Condition: 35°C DB Outdoor DB, ˚C Indoor WB Indoor DB ˚C ˚C TC (kW) SHC (kW) PI (kW) 1.89 0.58 ........... 2.04 1.45 0.59 Total capacity, TC Interpolation Method: 17º...
  • Page 78 Performance Data AWM-G2_(i) (b) Indoor Condition: 25°C DB, 17°C WB Outdoor Condition: 40°C DB Outdoor DB, ˚C Indoor WB Indoor DB ˚C ˚C TC (kW) SHC (kW) PI (kW) 1.73 1.68 0.63 ........... 1.87 1.35 0.64 Total capacity, TC Interpolation Method: 17º C – 16º C – 1.73kW ⇒ 18º C – 16º C 1.87kW –...
  • Page 79 AWM-G2_(i) Performance Data Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 25°C DB, 17°C WB Outdoor Condition: 37°C DB Outdoor DB, ˚C Indoor WB, Indoor DB, ˚C ˚C SHC SHC SHC (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) 1.94 1.68 0.58 1.78 1.24 0.63...
  • Page 80: Performance Data

    Performance Data AWM-G2_(i) Cooling Only (R22) Model: AWM 0G2 - ALC 0C Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 1.93 1.42 0.45 1.86 1.38 0.48 1.80 1.35 0.53 1.72 1.31 0.57 1.58 1.22 0.62 1.46 1.15 0.68 24°C 1.94 1.70 0.45 1.87 1.66 0.48 1.80 1.63 0.53...
  • Page 81 AWM-G2_(i) Performance Data Cooling Only (R22) Model: AWM 0G2 - ALC 0C Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 2.49 1.78 0.70 2.40 1.74 0.76 2.31 1.69 0.82 2.22 1.64 0.89 2.04 1.53 0.96 1.88 1.44 1.06 24°C 2.49 2.14 0.70 2.40 2.09 0.76 2.31 2.04 0.82...
  • Page 82 Performance Data AWM-G2_(i) Cooling Only (R22) Model: AWM 10G2 - ALC 10C Cooling Mode Outdoor temperature (CFM) 19°C 25°C 30°C 35°C 40°C 46°C 16°C 21°C 2.62 1.90 0.65 2.53 1.85 0.71 2.43 1.80 0.77 2.34 1.75 0.83 2.15 1.63 0.90 1.98 1.53 0.99 24°C 2.62 2.28 0.65 2.53 2.23 0.71 2.44 2.17...
  • Page 83 AWM-G2_(i) Performance Data Cooling Only (R22) Model: AWM 15G2 - ALC 15C Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 3.32 2.28 0.91 3.20 2.22 0.99 3.08 2.16 1.07 2.96 2.10 1.16 2.72 1.96 1.26 2.51 1.84 1.38 24°C 3.32 2.73 0.91 3.20 2.67 0.99 3.09 2.61 1.07...
  • Page 84 Performance Data AWM-G2_(i) Cooling Only (R22) Model: AWM 20G2 - ALC 1C Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 4.98 3.29 1.38 4.80 3.20 1.50 4.62 3.11 1.62 4.44 3.03 1.76 4.07 2.82 1.91 3.76 2.65 2.10 24°C 4.98 3.94 1.38 4.81 3.85 1.50 4.63 3.76 1.62...
  • Page 85 AWM-G2_(i) Performance Data Cooling Only (R22) Model: AWM 20G2 - ALC 20C Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 5.25 3.52 1.37 5.07 3.42 1.48 4.88 3.33 1.61 4.68 3.24 1.74 4.30 3.01 1.89 3.97 2.83 2.09 24°C 5.26 4.21 1.37 5.07 4.11 1.49 4.88 4.02 1.61...
  • Page 86 Performance Data AWM-G2_(i) Cooling Only (R22) Model: AWM 25G2 - ALC 25C Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 6.50 4.35 1.92 6.27 4.24 2.08 6.03 4.12 2.25 5.79 4.00 2.44 5.32 3.73 2.65 4.91 3.51 2.92 24°C 6.50 5.21 1.92 6.27 5.09 2.08 6.04 4.97 2.25...
  • Page 87 AWM-G2_(i) Performance Data Cooling Only (R22) Model: AWM 01 - ALC 2C Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 7.46 4.93 2.06 7.20 4.80 2.23 6.93 4.67 2.41 6.65 4.54 2.61 6.11 4.22 2.83 5.64 3.97 3.13 24°C 7.47 5.90 2.06 7.21 5.76 2.23 6.94 5.63 2.41...
  • Page 88 Performance Data AWM-G2_(i) Cooling Only (R22) Model: AWM 01 - ALC 0C Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 8.29 5.47 2.24 7.99 5.33 2.42 7.70 5.19 2.62 7.39 5.04 2.84 6.78 4.69 3.08 6.26 4.41 3.40 24°C 8.30 6.55 2.24 8.00 6.40 2.42 7.71 6.25 2.62...
  • Page 89 AWM-G2_(i) Performance Data Heat Pump (R22) Model: AWM 0G2R - ALC 0CR Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 2.49 1.78 0.70 2.40 1.74 0.76 2.31 1.69 0.82 2.22 1.64 0.89 2.04 1.53 0.96 1.88 1.44 1.06 24°C 2.49 2.14 0.70 2.40 2.09 0.76 2.31 2.04 0.82...
  • Page 90 Performance Data AWM-G2_(i) Model: AWM 0G2R - ALC 0CR Heating Mode Outdoor WB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 1.181 1.181 1.471 1.471 1.568 1.568 2.630 2.630 3.210 3.210 3.500 3.500 3.790 3.790 1.154 1.154 1.442 1.442 1.538 1.538 2.591 2.591 3.123...
  • Page 91 AWM-G2_(i) Performance Data Heat Pump (R22) Model: AWM 10G2R - ALC 10CR Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 2.62 1.90 0.65 2.53 1.85 0.71 2.43 1.80 0.77 2.34 1.75 0.83 2.15 1.63 0.90 1.98 1.53 0.99 24°C 2.62 2.28 0.65 2.53 2.23 0.71 2.44 2.17 0.77...
  • Page 92 Performance Data AWM-G2_(i) Model: AWM 10G2R - ALC 10CR Heating Mode Outdoor WB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 1.274 1.274 1.577 1.577 1.678 1.678 2.789 2.789 3.395 3.395 3.698 3.698 4.001 4.001 1.246 1.246 1.546 1.546 1.646 1.646 2.743 2.743 3.302...
  • Page 93 AWM-G2_(i) Performance Data Heat Pump (R22) Model: AWM 15G2R - ALC 15CR Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 3.32 2.28 0.91 3.20 2.22 0.99 3.08 2.16 1.07 2.96 2.10 1.16 2.72 1.96 1.26 2.51 1.84 1.38 24°C 3.32 2.73 0.91 3.20 2.67 0.99 3.09 2.61 1.07...
  • Page 94 Performance Data AWM-G2_(i) Model: AWM 15G2R - ALC 15CR Heating Mode Outdoor WB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 1.533 1.533 1.925 1.925 2.055 2.055 3.489 3.489 4.271 4.271 4.662 4.662 5.503 5.053 1.494 1.494 1.885 1.885 2.016 2.016 3.442 3.442 4.154...
  • Page 95 AWM-G2_(i) Performance Data Heat Pump (R22) Model: AWM 20G2R - ALC 1CR Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 4.98 3.29 1.38 4.80 3.20 1.50 4.62 3.11 1.62 4.44 3.03 1.76 4.07 2.82 1.91 3.76 2.65 2.10 24°C 4.98 3.94 1.38 4.81 3.85 1.50 4.63 3.76 1.62...
  • Page 96 Performance Data AWM-G2_(i) Model: AWM 20G2R - ALC 1CR Heating Mode Outdoor WB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 2.593 2.593 3.146 3.146 3.330 3.330 5.359 5.359 6.465 6.465 7.018 7.018 7.572 7.572 2.552 2.552 3.090 3.090 3.269 3.269 5.285 5.285 6.290...
  • Page 97 AWM-G2_(i) Performance Data Heat Pump (R22) Model: AWM 20G2R - ALC 20CR Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 5.25 3.52 1.37 5.07 3.42 1.48 4.88 3.33 1.61 4.68 3.24 1.74 4.30 3.01 1.89 3.97 2.83 2.09 24°C 5.26 4.21 1.37 5.07 4.11 1.49 4.88 4.02 1.61...
  • Page 98 Performance Data AWM-G2_(i) Model: AWM 20G2R - ALC 20CR Heating Mode Outdoor WB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 2.056 2.506 3.124 3.124 3.330 3.330 5.597 5.597 6.834 6.834 7.452 7.452 8.071 8.071 2.446 2.446 3.062 3.062 3.267 3.267 5.546 5.546 6.648...
  • Page 99 AWM-G2_(i) Performance Data Heat Pump (R22) Model: AWM 25G2R - ALC 25CR Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 6.50 4.35 1.92 6.27 4.24 2.08 6.03 4.12 2.25 5.79 4.00 2.44 5.32 3.73 2.65 4.91 3.51 2.92 24°C 6.50 5.21 1.92 6.27 5.09 2.08 6.04 4.97 2.25...
  • Page 100 Performance Data AWM-G2_(i) Model: AWM 25G2R - ALC 25CR Heating Mode Outdoor WB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 3.204 3.204 3.940 3.940 4.185 4.185 6.883 6.883 8.355 8.355 9.091 9.091 9.872 9.872 3.141 3.141 3.865 3.865 4.107 4.107 6.822 6.822 8.128...
  • Page 101 AWM-G2_(i) Performance Data Heat Pump (R22) Model: AWM 01R - ALC 2CR Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 7.46 4.93 2.06 7.20 4.80 2.23 6.93 4.67 2.41 6.65 4.54 2.61 6.11 4.22 2.83 5.64 3.97 3.13 24°C 7.47 5.90 2.06 7.21 5.76 2.23 6.94 5.63 2.41...
  • Page 102 Performance Data AWM-G2_(i) Model: AWM 01R - ALC 2CR Heating Mode Outdoor WB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 3.527 3.527 4.422 4.422 4.720 4.720 8.000 8.000 9.790 9.790 10.684 10.684 11.579 11.579 3.437 3.437 4.332 4.332 4.630 4.630 7.939 7.939 9.523...
  • Page 103 AWM-G2_(i) Performance Data Heat Pump (R22) Model: AWM 301R - ALC 30CR Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 8.29 5.47 2.24 7.99 5.33 2.42 7.70 5.19 2.62 7.39 5.04 2.84 6.78 4.69 3.08 6.26 4.41 3.40 24°C...
  • Page 104 Performance Data AWM-G2_(i) Model: AWM 01R - ALC 0CR Heating Mode Outdoor WBoC ID DBoC TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 5.37 5.37 6.20 6.20 6.47 6.47 9.50 9.50 11.15 11.15 11.98 11.98 12.80 12.80 5.37 5.37 6.11 6.11 6.36 6.36 9.26...
  • Page 105 AWM-G2_(i) Performance Data Cooling Only (R10A ) Model: A5WM 0G2 - A5LC 0C Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 2.07 1.49 0.52 2.00 1.45 0.56 1.93 1.41 0.61 1.85 1.37 0.66 1.70 1.27 0.71 1.57 1.20 0.78 24°C 2.08 1.78 0.52 2.00 1.74 0.56 1.93 1.70 0.61...
  • Page 106 Performance Data AWM-G2_(i) Cooling Only (R10A ) Model: A5WM 0G2 - A5LC 0C Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 2.49 1.74 0.65 2.40 1.69 0.71 2.31 1.65 0.77 2.22 1.60 0.83 2.04 1.49 0.90 1.88 1.40 0.99 24°C 2.49 2.08 0.65 2.40 2.03 0.71 2.31 1.98 0.77...
  • Page 107 AWM-G2_(i) Performance Data Cooling Only (R10A ) Model: A5WM 10G2 - A5LC 10C Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 2.62 1.88 0.69 2.53 1.83 0.75 2.43 1.78 0.81 2.34 1.73 0.88 2.15 1.61 0.95 1.98 1.51 1.05 24°C 2.62 2.25 0.69 2.53 2.20 0.75 2.44 2.15 0.81...
  • Page 108 Performance Data AWM-G2_(i) Cooling Only (R10A ) Model: A5WM 15G2 - A5LC 15C Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 3.32 2.28 0.93 3.20 2.22 1.01 3.08 2.16 1.09 2.96 2.10 1.19 2.72 1.96 1.29 2.51 1.84 1.42 24°C 3.32 2.73 0.93 3.20 2.67 1.01 3.09 2.61 1.09...
  • Page 109 AWM-G2_(i) Performance Data Cooling Only (R10A ) Model: A5WM 20G2 - A5LC 20C Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 4.93 3.30 1.24 4.76 3.22 1.34 4.58 3.13 1.45 4.40 3.04 1.57 4.04 2.83 1.71 3.73 2.66 1.88 24°C 4.94 3.95 1.24 4.76 3.86 1.34 4.59 3.77...
  • Page 110 Performance Data AWM-G2_(i) Cooling Only (R10A ) Model: A5WM 20G2 - A5LC 20C ( Phase) Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 4.98 3.33 1.26 4.80 3.25 1.37 4.62 3.16 1.48 4.44 3.07 1.60 4.07 2.86 1.74 3.76 2.69 1.92 24°C 4.98 3.99 1.26 4.81 3.90 1.37 4.63 3.81 1.48...
  • Page 111 AWM-G2_(i) Performance Data Cooling Only (R10A ) Model: A5WM 25G2 - A5LC 25C Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 5.62 4.03 1.41 5.42 3.92 1.53 5.22 3.82 1.66 5.01 3.71 1.79 4.60 3.45 1.95 4.25 3.25 2.15 24°C 5.63 4.82 1.41 5.43 4.71 1.53 5.23 4.60 1.66...
  • Page 112 Performance Data AWM-G2_(i) Cooling Only (R10A ) Model: A5WM 25G2 - A5LC 25C ( Phase) Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 6.21 4.45 1.67 5.99 4.34 1.80 5.77 4.22 1.95 5.54 4.10 2.12 5.09 3.81 2.30 4.70 3.59 2.53 24°C 6.22 5.33 1.67 6.00 5.21 1.80 5.78 5.09 1.95...
  • Page 113 AWM-G2_(i) Performance Data Cooling Only (R10A ) Model: A5WM 11 - A5LC 2C Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 7.18 4.68 1.95 6.93 4.55 2.10 6.67 4.43 2.28 6.40 4.30 2.47 5.88 4.01 2.68 5.43 3.77 2.95 24°C 7.19 5.60 1.95 6.94 5.47 2.10 6.68 5.34...
  • Page 114 Performance Data AWM-G2_(i) Cooling Only (R10A ) Model: A5WM 11 - A5LC 2C ( Phase) Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 7.18 4.68 2.00 6.93 4.55 2.16 6.67 4.43 2.34 6.40 4.30 2.54 5.88 4.01 2.75 5.43 3.77 3.04 24°C 7.19 5.60 2.00 6.94 5.47 2.16 6.68 5.34...
  • Page 115 AWM-G2_(i) Performance Data Heat Pump (R10A) Model: A5WM 0G2R - A5LC 0CR Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 2.07 1.49 0.52 2.00 1.45 0.56 1.93 1.41 0.61 1.85 1.37 0.66 1.70 1.27 0.71 1.57 1.20 0.78 24°C 2.08 1.78 0.52 2.00 1.74 0.56 1.93 1.70 0.61...
  • Page 116 Performance Data AWM-G2_(i) Model: A5WM 0G2R - A5LC 0CR Heating Mode Outdoor WB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 1.329 1.329 1.504 1.504 1.562 1.562 2.205 2.205 2.555 2.555 2.730 2.730 2.905 2.905 1.294 1.294 1.418 1.418 1.522 1.522 2.202 2.202 2.494...
  • Page 117 AWM-G2_(i) Performance Data Heat Pump (R10A) Model: A5WM 0G2R - A5LC 0CR Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 2.49 1.74 0.65 2.40 1.69 0.71 2.31 1.65 0.77 2.22 1.60 0.83 2.04 1.49 0.90 1.88 1.40 0.99 24°C 2.49 2.08 0.65 2.40 2.03 0.71 2.31 1.98 0.77...
  • Page 118 Performance Data AWM-G2_(i) Model: A5WM 0G2R - A5LC 10CR Heating Mode Outdoor WB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 1.595 1.595 1.805 1.805 1.875 1.875 2.646 2.646 3.066 3.066 3.276 3.276 3.486 3.486 1.553 1.553 1.786 1.786 1.831 1.831 2.642 2.642 3.015...
  • Page 119 AWM-G2_(i) Performance Data Heat Pump (R10A) Model: A5WM 10G2R - A5LC 10CR Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 2.62 1.88 0.69 2.53 1.83 0.75 2.43 1.78 0.81 2.34 1.73 0.88 2.15 1.61 0.95 1.98 1.51 1.05 24°C 2.62 2.25 0.69 2.53 2.20 0.75 2.44 2.15 0.81...
  • Page 120 Performance Data AWM-G2_(i) Model: A5WM 10G2R - A5LC 10CR Heating Mode Outdoor WB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 1.683 1.683 1.905 1.905 1.979 1.979 2.793 2.793 3.236 3.236 3.458 3.458 3.680 3.680 1.639 1.639 1.870 1.870 1.932 1.932 2.789 2.789 3.175...
  • Page 121 AWM-G2_(i) Performance Data Heat Pump (R10A) Model: A5WM 15G2R - A5LC 15CR Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 3.32 2.28 0.93 3.20 2.22 1.01 3.08 2.16 1.09 2.96 2.10 1.19 2.72 1.96 1.29 2.51 1.84 1.42 24°C 3.32 2.73 0.93 3.20 2.67 1.01 3.09 2.61 1.09...
  • Page 122 Performance Data AWM-G2_(i) Model: A5WM 15G2R - A5LC 15CR Heating Mode Outdoor WB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 2.126 2.126 2.406 2.406 2.500 2.500 3.528 3.528 4.088 4.088 4.368 4.368 4.649 4.649 2.070 2.070 2.288 2.288 2.440 2.440 3.523 3.523 4.013...
  • Page 123 AWM-G2_(i) Performance Data Heat Pump (R10A) Model: A5WM 20G2R - A5LC 20CR Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 4.93 3.30 1.24 4.76 3.22 1.34 4.58 3.13 1.45 4.40 3.04 1.57 4.04 2.83 1.71 3.73 2.66 1.88 24°C 4.94 3.95 1.24 4.76 3.86 1.34 4.59 3.77 1.45...
  • Page 124 Performance Data AWM-G2_(i) Model: A5WM 20G2R - A5LC 20CR (1 PHASE) Heating Mode Outdoor WB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 3.189 3.189 3.610 3.610 3.750 3.750 5.291 5.291 6.132 6.132 6.553 6.553 6.973 6.973 3.106 3.106 3.514 3.514 3.677 3.677 5.285 5.285 6.106...
  • Page 125 AWM-G2_(i) Performance Data Heat Pump (R10A) Model: A5WM 20G2R - A5LC 20CR ( Phase) Cooling Mode Outdoor temperature (CFM) 19°C 25°C 30°C 35°C 40°C 46°C 16°C 21°C 4.98 3.33 1.26 4.80 3.25 1.37 4.62 3.16 1.48 4.44 3.07 1.60 4.07 2.86 1.74 3.76 2.69 1.92 24°C 4.98 3.99 1.26 4.81 3.90 1.37 4.63 3.81...
  • Page 126 Performance Data AWM-G2_(i) Model: A5WM 20G2R - A5LC 20CR ( PHASE) Heating Mode Outdoor WB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 3.278 3.278 3.710 3.710 3.854 3.854 5.438 5.438 6.302 6.302 6.735 6.735 7.167 7.167 3.192 3.192 3.598 3.598 3.776 3.776 5.432 5.432 6.259...
  • Page 127 AWM-G2_(i) Performance Data Heat Pump (R10A) Model: A5WM 25G2R - A5LC 25CR Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 5.62 4.03 1.41 5.42 3.92 1.53 5.22 3.82 1.66 5.01 3.71 1.79 4.60 3.45 1.95 4.25 3.25 2.15 24°C 5.63 4.82 1.41 5.43 4.71 1.53 5.23 4.60 1.66...
  • Page 128 Performance Data AWM-G2_(i) Model: A5WM 25G2R - A5LC 25CR (1 PHASE) Heating Mode Outdoor WB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 3.898 3.898 4.412 4.412 4.583 4.583 6.467 6.467 7.495 7.495 8.009 8.009 8.523 8.523 3.796 3.796 4.288 4.288 4.495 4.495 6.459 6.459 7.469...
  • Page 129 AWM-G2_(i) Performance Data Heat Pump (R10A) Model: A5WM 25G2R - A5LC 25CR ( Phase) Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 6.21 4.45 1.67 5.99 4.34 1.80 5.77 4.22 1.95 5.54 4.10 2.12 5.09 3.81 2.30 4.70 3.59 2.53 24°C 6.22 5.33 1.67 6.00 5.21 1.80 5.78 5.09 1.95...
  • Page 130 Performance Data AWM-G2_(i) Model: A5WM 25G2R - A5LC 25CR ( PHASE) Heating Mode Outdoor WB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 4.075 4.075 4.612 4.612 4.791 4.791 6.761 6.761 7.835 7.835 8.373 8.373 8.910 8.910 3.968 3.968 4.514 4.514 4.685 4.685 6.753 6.753 7.732...
  • Page 131 AWM-G2_(i) Performance Data Heat Pump (R10A) Model: A5WM 01R - A5LC 2CR Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 7.18 4.68 1.95 6.93 4.55 2.10 6.67 4.43 2.28 6.40 4.30 2.47 5.88 4.01 2.68 5.43 3.77 2.95 24°C 7.19 5.60 1.95 6.94 5.47 2.10 6.68 5.34 2.28...
  • Page 132 Performance Data AWM-G2_(i) Model: A5WM 01R - A5LC 2CR (1 &  PHASE) Heating Mode Outdoor WB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 4.607 4.607 5.214 5.214 5.416 5.416 7.643 7.643 8.858 8.858 9.465 9.465 10.072 10.072 4.486 4.486 5.121 5.121 5.289 5.289 7.634 7.634 8.703...
  • Page 133 AWM-G2_(i) Performance Data Heat Pump (R10A) Model: A5WM 01R - A5LC 2CR ( Phase) Cooling Mode Outdoor temperature 19°C 25°C 30°C 35°C 40°C 46°C (CFM) 21°C 7.18 4.68 2.00 6.93 4.55 2.16 6.67 4.43 2.34 6.40 4.30 2.54 5.88 4.01 2.75 5.43 3.77 3.04 24°C 7.19 5.60 2.00 6.94 5.47 2.16 6.68 5.34 2.34...
  • Page 134 AAWM-G2_(i) Performance Data Model: A5WM 301R - A5LC 28CR (3 Phase) Heating Mode Outdoor WB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 1.533 1.533 1.925 1.925 2.055 2.055 3.489 3.489 4.271 4.271 4.662 4.662 5.503...
  • Page 135: Outline And Dimension

    AWM-G2_(i) Outline and Dimension Outline and Dimension Indoor Unit Model: AWM 0G2/0G2/G2R, A5WM 0/0G2/G2R TOP VIEW FRONT VIEW SIDE VIEW INSTALLATION PLATE All dimensions are in mm / (in) Dimension 07/09G2 (31.5) (10.2) (7.8) (15.0) (9.7) (7.3) (4.9) (0.3) (2.2) (2.0) (12.6) (15.0) (2.0) (5.1) (5.2) Outdoor Unit Model: ALC 0C/0C/CR, A5LC 0C/CR Note: Dimension in mm...
  • Page 136 Outline and Dimension AWM-G2_(i) Indoor Unit Model: AWM 10/15G2/G2R, A5WM 10/15G2/G2R TOP VIEW FRONT VIEW SIDE VIEW INSTALLATION PLATE All dimensions are in mm / (in) All dimensions are in mm / (in) Dimension 10/15G2 (35.4) (10.2) (7.8) (23.2) (9.7) (7.3) (4.9) (0.3) (2.2) (2.0) (16.5) (19.5) (2.0) (5.1) (5.2)
  • Page 137 AWM-G2_(i) Outline and Dimension Indoor Unit Model: AWM 20/25G2/G2R, A5WM 20/25G2/G2R TOP VIEW FRONT VIEW SIDE VIEW INSTALLATION PLATE All dimensions are in mm / (in) Dimension 1062 20/25G2 (41.8) (12.0) (8.7) (35.9) (11.6) (3.9) (2.0) (0.3) (1.9) (1.7) (13.9) (15.9) (6.3) (5.4) (6.3) Outdoor Unit Model: ALC 1/20/25C/CR, A5LC 20/25C/CR For A5LC / ALC 25C/CR Note : Dimension in mm MODEL ALC 18C/20C/20CR...
  • Page 138 Outline and Dimension AWM-G2_(i) Indoor Unit Model: AWM 301/301R, A5WM 311/301R Note: Dimension in mm Outdoor Unit Model: A5LC 28C/CR For A5LC / ALC 28 C/CR Only Note : Dimension in mm MODEL ALC 28C/28CR A5LC 28C/28CR Note: Dimension in mm...
  • Page 139 AWM-G2_(i) Outline and Dimension Indoor Unit Model : AWM 301/301R Note: Dimension in mm Outdoor Unit Model : ALC 30C/CR Note: Dimension in mm...
  • Page 140: Electrical Data

    Electrical Data AWM-G2_(i) Electrical Data Electrical Data - Cooling Only (R22) INDOOR UNIT AWM 0G2 AWM 0G2 MODEL OUTDOOR UNIT ALC 0C ALC 0C INSULATION GRADE CLASS E CLASS E POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.11 0.11 MOTOR OUTPUT POLES INSULATION GRADE CLASS B CLASS B...
  • Page 141 AWM-G2_(i) Electrical Data Electrical Data - Cooling Only (R22) INDOOR UNIT AWM 10G2 AWM 15G2 MODEL OUTDOOR UNIT ALC 10C ALC 15C INSULATION GRADE CLASS E CLASS E POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.11 0.13 MOTOR OUTPUT POLES INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz...
  • Page 142 Electrical Data AWM-G2_(i) Electrical Data - Cooling Only (R22) INDOOR UNIT AWM 20G2 AWM 20G2 MODEL OUTDOOR UNIT ALC 1C ALC 20C INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.22 0.22 MOTOR OUTPUT POLES INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz...
  • Page 143 AWM-G2_(i) Electrical Data Electrical Data - Cooling Only (R22) INDOOR UNIT AWM 25G2 AWM 01 MODEL OUTDOOR UNIT ALC 25C ALC 2C INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.29 0.30 MOTOR OUTPUT POLES INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz...
  • Page 144 Electrical Data AWM-G2_(i) Electrical Data - Cooling Only (R10A) INDOOR UNIT A5WM 0G2 A5WM 0G2 MODEL OUTDOOR UNIT A5LC 0C A5LC 10C INSULATION GRADE CLASS E CLASS E POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.11 0.11 MOTOR OUTPUT POLES INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz...
  • Page 145 AWM-G2_(i) Electrical Data Electrical Data - Cooling Only (R10A) INDOOR UNIT A5WM 10G2 A5WM 15G2 MODEL OUTDOOR UNIT A5LC 10C A5LC 15C INSULATION GRADE CLASS E CLASS E POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.11 0.13 MOTOR OUTPUT POLES INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz...
  • Page 146 Electrical Data AWM-G2_(i) Electrical Data - Cooling Only (R10A) INDOOR UNIT A5WM 20G2 A5WM 25G2 MODEL OUTDOOR UNIT A5LC 20C A5LC 25C INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.22 0.29 MOTOR OUTPUT POLES INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz...
  • Page 147 AWM-G2_(i) Electrical Data Electrical Data - Cooling Only (R410A) INDOOR UNIT A5WM 311 MODEL OUTDOOR UNIT A5LC 28C INSULATION GRADE CLASS B POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.30 MOTOR OUTPUT IP24...
  • Page 148: Wiring Diagram

    Wiring Diagram AWM-G2_(i) Wiring Diagram Cooling Only Indoor Unit Outdoor Unit Model: AWM 0/0/10G2 Model: ALC 0/0/10C A5WM 0/0/10/15G2 A5LC 0/10/15C...
  • Page 149 AWM-G2_(i) Wiring Diagram Cooling Only Indoor Unit Outdoor Unit Model: AWM 15G2 Model: ALC 15C...
  • Page 150 Wiring Diagram AWM-G2_(i) Cooling Only Indoor Unit Outdoor Unit Model: AWM 20/25G2 Model: ALC 20/25C A5WM 20/25G2 A5LC 20/25C...
  • Page 151 AWM-G2_(i) Wiring Diagram Cooling Only Indoor Unit Outdoor Unit Model: AWM 20G2 Model: ALC 1C...
  • Page 152 Wiring Diagram AWM-G2_(i) Cooling Only Indoor Unit Outdoor Unit Model: AWM 01 Model: ALC 2C A5WM 11 A5LC 2C...
  • Page 153 AWM-G2_(i) Wiring Diagram Cooling Only Indoor Unit Outdoor Unit Model: AWM 01 Model: ALC 0C...
  • Page 154 Wiring Diagram AWM-G2_(i) Cooling Only Indoor Unit MODEL : A5WM 20/25G2 - A5LC 20/25C (With Low Ambient Kit)
  • Page 155 AWM-G2_(i) Wiring Diagram Cooling Only Indoor Unit MODEL : A5WM 11 - A5LC 2C (With Low Ambient Kit)
  • Page 156 Wiring Diagram AWM-G2_(i) Heat Pump Indoor Unit Outdoor Unit Model: AWM 0/10G2R Model: ALC 0/10CR A5WM 0/10/15G2R A5LC 0/10/15CR...
  • Page 157 AWM-G2_(i) Wiring Diagram Heat Pump Indoor Unit Outdoor Unit Model: AWM 15G2R Model: ALC 15CR...
  • Page 158 Wiring Diagram AWM-G2_(i) Heat Pump Indoor Unit Outdoor Unit Model: AWM 20/25G2R Model: ALC 20/25CR A5WM 20/25G2R A5LC 20/25CR...
  • Page 159 AWM-G2_(i) Wiring Diagram Heat Pump Indoor Unit Outdoor Unit Model: AWM 01R Model: ALC 2CR A5WM 01R A5LC 2CR...
  • Page 160 Wiring Diagram AWM-G2_(i) Heat Pump Indoor Unit Outdoor Unit Model: AWM 01R Model: ALC 0CR...
  • Page 161: Service And Maintenance

    AWM-G2_(i) Service and Maintenance Service and Maintenance Indoor Models Warning • The unit is designed to give a long life operation with minimum maintenance required. However, it should be regularly checked and the following items should be given due attention. Components Maintenance Procedures Period Air Filter 1.
  • Page 162 Service and Maintenance AWM-G2_(i) Pre Start Up Maintenance (After Extended Shutdown) • Inspect thoroughly and clean indoor and outdoor units. • Clean or replace air filters. • Clean condensates drain line. • Clean clogged indoor and outdoor coils. • Check fan imbalance before operation. • Tighten all wiring connections and panels. •...
  • Page 163: Troubleshooting

    AWM-G2_(i) Troubleshooting Troubleshooting Error Code / Fault Condition When a malfunction of the air conditioner unit is detected, immediately switch off the main power supply before proceeding with the following troubleshooting procedures. The following are common fault conditions and simple troubleshooting tips. If any other fault conditions which are not listed occur, contact your nearest local dealer.
  • Page 164 Troubleshooting AWM-G2_(i) Diagnostic Guidelines By means of pressure readings: Data Pressure Probable cause Circuit High side 1. Overcharged with refrigerant. • Low side 2. Non-condensable gases in refrigerant circuit (e.g. air) • 3. Obstructed air-intake / discharge. 4. Hot air short circuiting in outdoor unit. High side 1. Poor compression /no compression (compressor •...
  • Page 165 AWM-G2_(i) Troubleshooting By means of diagnostic flow chart: Generally, there are two kinds of problems, i.e. starting failure and insufficient cooling/heating. “Starting failure” is caused by electrical defect while improper application or defects in refrigerant circuit causes “Insufficient cooling / heating”. i ) Diagnosis of Electric circuit : Faulty : Check...
  • Page 166 Troubleshooting AWM-G2_(i) Change the contactor Coil burnt Faulty Condenser fan contactor Change the contacts Contact faulty Repair or replace the motor contactor Fan motor faulty Other electrical Repair or change if necessary component faulty Change the contactor Coil burnt Faulty Evaporator contactor Change the contacts...
  • Page 167 AWM-G2_(i) Troubleshooting ii ) Diagnosis of Refrigerant Circuit / Application There might be some causes where the unit starts running but does not perform satisfactorily, i.e. insufficient cooling. Judgement could be made by measuring temperature difference of indoor unit’s intake and discharge air as well as running current.
  • Page 168 Troubleshooting AWM-G2_(i) Insufficient heating Indoor/outdoor coil dirty Clean the coil (clogged) Restricted circulation Clean the filter Indoor air filter dirty Change or repair the motor Fan motor malfunction Obstruction at air inlet Remove the obstruction /outlet of indoor / outdoor unit Windows / doors wide High heating...
  • Page 169 AWM-G2_(i) Troubleshooting Indicator Lights AWM / A5WM - G SERIES IR Signal Receiver When there is infrared remote control operating signal, the signal receiver on indoor unit will made a (beep) for signal acceptance confirmation. Cooling unit / Heatpump unit The table below shows the LED indicator light for air conditioner unit under normal operation and fault condition. The LED indicator lights are located at the middle of the air conditioner unit.
  • Page 170 Troubleshooting AWM-G2_(i) LED Indicator Lights : Normal Operation and Fault Indication Table  Normal Operation / Fault Indication Action COOL/HEAT (GREEN/RED) Cool mode Green Heat mode Auto mode in Heating operation Auto mode in Cooling operation Green Timer on Sleep mode on Ionizer on Fan mode on Dry mode on Room air sensor contact Loose / Short...
  • Page 171 AWM-G2_(i) Troubleshooting AWM 301 / 301R , A5WM 311 / 301R LED Indicator Lights for Cooling Unit  Power On Timer Dry mode Sleep mode LED Indicator Lights : Normal Operation and Fault Conditions for Cooling Unit  Normal Operation / Fault Indication Action Power Timer Sleep Timer on Sleep mode on Dry mode on Clean the filter and...
  • Page 172 Troubleshooting AWM-G2_(i) LED Indicator Lights For Heatpump Unit Cooling mode Dry mode Heat/Fan mode Sleep mode (red/green) LED Indicator Lights : Normal Operation and Fault Conditions for Cooling Unit Normal Operation / Action Fault Indication Cool Heat Sleep Cooling mode Dry mode Fan mode Heat mode Auto mode in heating operation Auto mode in cooling operation Defrost operation Compressor overload protection...
  • Page 173: Exploded View And Part List

    AWM-G2_(i) Exploded View and Part List Exploded View and Part List INDOOR UNIT MODEL: AWM/A5WM 0/0G2/G2R No Description No Description ASSY., CHASIS DRAIN HOSE FAN, MOTOR ASSY., CONTROL BOX CROSS FLOW FAN ASSY., CONTROL BOX COVER FAN, BUSH ASSY., FRONT COVER ASSY., COIL ASSY., AIR DISCHARGE HOUSING PIPING, CLAMP ASSY, MOUNTING PLATE ASSY., DRAIN PAN...
  • Page 174 AWM-G2_(i) Exploded View and Part List INDOOR UNIT MODEL: AWM/A5WM 10/15G2/G2R No Description No Description ASSY., CHASIS DRAIN HOSE FAN, MOTOR ASSY., CONTROL BOX CROSS FLOW FAN ASSY., CONTROL BOX COVER FAN, BUSH ASSY., FRONT COVER ASSY., COIL ASSY., AIR DISCHARGE HOUSING PIPING, CLAMP ASSY, MOUNTING PLATE ASSY., DRAIN PAN SCREW, S.T.
  • Page 175 AWM-G2_(i) Exploded View and Part List INDOOR UNIT MODEL: AWM/A5WM 20/25G2/G2R No Description No Description ASSY., CHASIS COVER, PIPING FAN, MOTOR ASSY., CONTROL BOX COVER CROSS FLOW FAN ASSY., FRONT COVER FAN, BUSH SERVICE PANEL ASSY., COIL ASSY., AIR DISCHARGE HOUSING PIPING, CLAMP ASSY, MOUNTING PLATE ASSY., DRAIN PAN SCREW, S.T.
  • Page 176 AWM-G2_(i) Exploded View and Part List INDOOR UNIT MODEL: AWM 01/01R, A5WM 11/01R No Description No Description Assy. Installation Bracket Handset, Wireless G18 Assy. Chassis Control Box Cover Piping Clamp Assy. Drain Hose Fan Bush Bracket Air Swing Motor Cross Flow Fan Air Louver Fan Bush Assy. Air Discharge Housing Assy.
  • Page 177 AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: ALC 0C No Description No Description Assy. Base Pan Left Panel Compressor Right Panel Assy. Outdoor Coil Assy. Control Panel Valve Bracket Top/Front Panel Assy. Partition Assy. Valve Cover Assy. Suction Tube Assy. Front Grille Assy. Discharge Tube Parts Not in Diagram Assy.
  • Page 178 AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: ALC 0C/CR No Description No Description Assy. Base Pan Assy. Control Panel Assy. Outdoor Coil Top/Front Panel Valve Bracket Assy. Valve Cover Compressor Assy. Front Grille Assy. Partition Plastic Handle Assy. Cap Tube Parts Not in Diagram Bracket, Fan Motor Capacitor, Fan Motor Fan Motor Capacitor, Compressor Fan Propeller...
  • Page 179 AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: ALC 10/15C/CR No Description No Description Assy. Base Pan Top/Front Panel Assy. Outdoor Coil Assy. Front Grille Compressor Fan Propeller Valve Bracket Parts Not in Diagram Assy. Partition Capacitor, Fan Motor Assy. Cap Tube Capacitor, Compressor Left Panel Assy. Flare Valve 2 Ways 1/4” Right Panel Assy.
  • Page 180 AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: ALC 1/20C/CR No Description No Description Assy. Base Pan Assy. Front Grille Assy. Outdoor Coil Plastic Handle Bracket, Fan Motor Assy. Valve Cover Fan Motor Assy. Cap Tube Fan Propeller Partition Assy. Valve Bracket Parts Not in Diagram Back Panel, Right Capacitor, Fan Motor Compressor Capacitor, Compressor...
  • Page 181 AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: ALC 25/2C/CR No Description No Description Assy. Base Pan Assy. Control Panel Assy. Outdoor Coil Top Panel Bracket, Fan Motor Assy. Front Grille Fan Motor Plastic Handle Fan Propeller Assy. Valve Cover Assy. Valve Bracket Assy. Cap Tube Back Panel, Right Partition Compressor...
  • Page 182 AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: ALC 0C/CR No Description No Description Assy. Base Pan Fan Motor Assy. 3 Way VLV 3/8” Fan Blade Assy. 3 Way VLV 5/8” Assy. Front Panel Assy. Panel, Partition Valve Plate Assy. Compressor Parts Not in Diagram Service Panel Capacitor, Compressor Accumulator Capacitor, Fan Motor Panel, Back Right...
  • Page 183 AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 0C/CR No Description No Description Assy. Base Pan Top/Front Panel Assy. Outdoor Coil Assy. Front Grille Valve Bracket Assy. Valve Cover Compressor Plastic Handle Assy. Partition Assy. 2 Ways Valve 1/4” Assy. Cap Tube Assy. 3 Ways Valve 3/8” Bracket, Fan Motor Parts Not in Diagram Fan Motor...
  • Page 184 AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 10/15C/CR No Description No Description Assy. Base Pan Assy. Valve Cover Assy. Outdoor Coil Assy. Front Grille Valve Bracket Plastic Handle Compressor Assy. 2 Ways Valve 1/4” Assy. Partition Assy. 3 Ways Valve 3/8” Assy. Cap Tube A5LC 10C/CR Bracket, Fan Motor Assy.
  • Page 185 AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 20C/CR No Description No Description Assy. Base Pan Top Panel Assy. Outdoor Coil Assy. Front Grille Bracket, Fan Motor Plastic Handle Fan Motor Assy. Valve Cover Fan Propeller Assy. Cap Tube Assy. Valve Bracket Partition Assy. 3 Ways Valve 1/2” Parts Not in Diagram Assy.
  • Page 186 AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 25/2C/CR No Description No Description Assy. Base Pan Terminal Cover Panel Assy. Outdoor Coil Assy. Control Panel Bracket, Fan Motor Top Panel Fan Motor Assy. Front Grille Fan Propeller Plastic Handle Assy. Valve Bracket Assy. Valve Cover Assy.
  • Page 187 AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 20C/CR ( phase) No Description No Description Assy. Base Pan Top Panel Assy. Outdoor Coil Assy. Front Grille Bracket, Fan Motor Plastic Handle Fan Motor Assy. Valve Cover Fan Propeller Assy. Cap Tube Assy. Valve Bracket Partition Assy. 3 Ways Valve 1/2” Parts Not in Diagram Assy.
  • Page 188 AWM-G2_(i) Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 25/2C/CR ( phase) No Description No Description Assy. Base Pan Service Panel Assy. Outdoor Coil Assy. Control Panel Bracket, Fan Motor Top Panel Fan Motor Assy. Front Grille Fan Propeller Plastic Handle Assy. Valve Bracket Assy. Valve Cover Assy. 3 Ways Valve 5/8” Assy.
  • Page 190 While upmost care is taken in ensuring that all details in the publication are correct at time of going to press, we are constantly striving for improvement and therefore reserve the rights to alter model specifications and equipment without prior notice. Details of speci fications andequipment are also subject to change to suit local conditions and equirements and not all models are available in every market.