GENERAL:
OSCO gate operators are designed for many years of trouble-free operation and, under recommended operating conditions, will
require only minimal maintenance. To ensure that your unit is ready for operation at all times--and to preclude serious damage
or failure--inspect the unit systematically. Proper adjustments and lubrication should be made as recommended.
LUBRICATION:
Motor. Motors have sealed ball bearings and do not require further lubrication. If bearing noise develops after several years of
operation, bearings should be replaced by a motor repair company, or the motor should be replaced if necessary.
Shoulder Bolts. Lubricate the front and back shoulder bolts twice a year with a lithium complex-based grease.
Actuator Cylinder. Wipe down the cylinder with WD40 or similar lubricant.
Power and Limits Cable. Inspect the operator to control box cable for cracks in the insulation, breaks, or other signs of failure.
Check all connection points. Replace if necessary.
ADDITIONAL SIX MONTH PREVENTATIVE MAINTENANCE:
1. Inspect all nuts and bolts for proper tightness and tighten as necessary.
2. Check all reversing devices for proper function. Inspect all contact edges for wear and replace if required. Check photo-eyes
for proper alignment and function.
3. Check current sensing for proper adjustment when finished with inspection and maintenance.
4. Inspect the installation area. Are all the warning signs intact and visible? If they are missing or need replaced, contact
OSCO. Be sure there are no control stations mounted within reach of the gate. Review safety literature with the customer
and advise them to remove any such stations found.
The gel-cell batteries in this operator require no routine maintenance. For assured continued performance, they should be
replaced every year.
If power is to be removed for one week or more, turn power switch off, as this will prevent deep discharging.
Fully charge before use after storage or upon initial installation.

PREVENTATIVE MAINTENANCE

PREVENTATIVE MAINTENANCE
PREVENTATIVE MAINTENANCE
PREVENTATIVE MAINTENANCE
PREVENTATIVE MAINTENANCE
WARNING!
YOU MUST TURN OFF THE POWER SWITCH
LOCATED IN THE LA36 CONTROL BOX BEFORE
SERVICING THE GATE OR GATE OPERATOR!
KEEP CLEAR OF THE GATE DURING OPERATION!

BATTERY MAINTENANCE

BATTERY MAINTENANCE
BATTERY MAINTENANCE
BATTERY MAINTENANCE
BATTERY MAINTENANCE
You must inspect the gate for proper operation. The
gate should move easily without binding through its
entire travel. If the gate does bind, adjust or fix as
required. Failure to keep the gate in good working
condition will have adverse effects on the operator.