Table of Contents
loading

Summary of Contents for Fluke IT100 IntelliTone Toner

  • Page 1 IT100  IntelliTone Toner and Probe Users Manual October 2003 Rev. 1 6/05 © 2003, 2005 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies.
  • Page 2 90 days, unless otherwise stated. Ni-Cad, Ni-MH and Li-Ion batteries, cables or other peripherals are all considered parts or acces- sories. The warranty extends only to the original buyer or end user customer of a Fluke Networks authorized reseller, and does not apply to any product which, in Fluke Networks’...
  • Page 3: Table Of Contents

    Table of Contents Title Page Overview of Features....................1 Registration ........................2 Contacting Fluke Networks ..................2 Unpacking ........................3 ITK100 IntelliTone Kit ....................3 IT100 IntelliTone Toner.................... 3 IT100 IntelliTone Probe.................... 3 Safety Information......................4 Battery Status ........................ 5 Auto Power Down ......................
  • Page 4 IT100 Users Manual Maintenance......................... 11 Battery Life and Replacement................. 11 Accessories ....................... 12 Specifications ........................ 13 Environmental and Regulatory Specifications ............13 IT100 Toner Electrical and Functional Specifications ..........14 IT100 Probe Electrical and Functional Specifications ..........14 Feature Compatibility....................15 Certifications and Compliance ................
  • Page 5 List of Figures Figure Title Page Locating and Isolating Cables....................7 Validating Telephone Service and Polarity................. 8 Continuity Test ........................9 Powering a Telephone Test Set ................... 10 Replacing the Battery ......................12...
  • Page 6 IT100 Users Manual...
  • Page 7: Overview Of Features

     IT100 IntelliTone Toner  IT100 IntelliTone Probe The IT100 toner and probe also provide standard Overview of Features functions such as visual and audible signal strength  The IT100 IntelliTone toner and probe let you locate and indication, legacy 1 kHz analog toning and detection, isolate twisted pair (UTP, Cat 5e, Cat 6), coax cables (RG6, continuity testing, and talk battery power for telephone RG59, and others for CATV/CCTV), bare wire (such as...
  • Page 8: Registration

    To +1-425-446-4519 register, fill out the online registration form on the Fluke Networks website at www.flukenetworks.com/registration. • Australia: 61 (2) 8850-3333 or 61 (3) 9329-0244 If you do not have Internet access, print the registration •...
  • Page 9: Unpacking

    Unpacking IT100 IntelliTone Toner Unpacking • IT100 Toner with 9 V battery The IT100 products come with the accessories listed • 1 RJ11 to RJ11 patch cord below. If something is damaged or missing, contact the • 1 RJ45 to RJ45 patch cord place of purchase immediately.
  • Page 10: Safety Information

    IT100 Users Manual • Safety Information Never use the toner, probe, or test leads if they are damaged. Inspect the cases and test leads Table 1 describes the international electrical symbols used for damage before use. on the tester and in this manual. •...
  • Page 11: Battery Status

    Battery Status Battery Status Auto Power Down LEDs on the toner and probe light for 1 second at power The toner turns off automatically after 4 hours of on to indicate the battery status: inactivity. The probe turns off automatically after 1 hour of inactivity.
  • Page 12 IT100 Users Manual To locate and isolate cables, do the following: Note If you cannot locate the IntelliTone signal on Connect the IT100 toner to a jack or punch-down 2-conductor cables, the cable may be shorted. block as shown in Figure 1. Use the continuity test (page 9) to check for Turn the toner’s rotary switch to for a one-note...
  • Page 13 Locating and Isolating Cables with the IntelliTone Function Connecting the Toner Locating Cables Isolating Cables Two-note One-note tone tone Volume control asx04f.eps Figure 1. Locating and Isolating Cables...
  • Page 14: Validatingtelephone Service And Polarity

    IT100 Users Manual Validating Telephone Service and Telephone RJ45 punch-down Polarity RJ11 block The toner detects telephone service and circuit polarity on its banana, RJ11, and RJ45 jacks. Note This test requires power from the Central Office battery. Turn off the toner. Line 1 Connect the toner to the circuit as shown in Figure 2.
  • Page 15: Testing For Continuity

    Testing for Continuity Testing for Continuity You can use the toner to test circuits and components for continuity. If you are testing a circuit, verify that it is not powered. Use the toner’s SERVICE function to check voice circuits for power. Use a voltage meter to check other types of circuits for power.
  • Page 16: Powering A Telephone Test Set

    IT100 Users Manual Powering a Telephone Test Set The toner can supply 6 V into a 600 Ω circuit to power a telephone test set when Central Office battery power is not present. Turn off the toner. Connect the toner to the voice circuit as shown in Figure 4.
  • Page 17: Toning/Probing With The 1 Khz Tone Function

    Toning/Probing with the 1 kHz Tone Function Battery Life and Replacement Toning/Probing with the 1 kHz Tone Function The toner and probe batteries last for about 20 hours of typical use. The IntelliTone signal from the IT100 toner includes a 1 kHz tone you can trace with an analog probe.
  • Page 18: Accessories

    IT100 Users Manual Accessories To order accessories (Table 2), contact Fluke Networks. For the latest list of IT100 accessories and other cable testers visit the Fluke Networks website at www.flukenetworks.com. Table 2. Accessories Fluke Networks Model Accessory or Part Number...
  • Page 19: Specifications

    Specifications Specifications Specifications apply at 23 C (73 F), unless otherwise noted. Environmental and Regulatory Specifications Operating temperature 32 °F to 104 °F (0 C to 40 Storage temperature -4 °F to +140 °F (-20 C to +60 Operating relative humidity 95 % (50 °F to 95 °F;...
  • Page 20: It100 Toner Electrical And Functional Specifications

    IT100 Users Manual IT100 Toner Electrical and Functional Specifications 6 V into 600 Ω Talk battery voltage Output power 5 V p-p Voltage protection 100 V  Tone frequencies IntelliTone signals: two encoded digital signals Legacy tone: 1 kHz analog tone Battery type and life 9 V alkaline (NEDA 1604A or IEC 6LR61);...
  • Page 21: Feature Compatibility

    Specifications Feature Compatibility Product Compatibility IntelliTone Toner/Probe Feature IntelliTone Toner and Probe Works with Legacy Toner or Probe IntelliTone locate mode IntelliTone isolate mode Cable map validation Shield validation Legacy 1 kHz tone Visual / audible proximity indicators Requires IntelliTone IP200 probe. Probe: 8.73 in x 1.88 in x 1.26 in Certifications and Compliance (22.2 cm x 4.8 cm x 3.2 cm)
  • Page 22 IT100 Users Manual...