TAPPING and CLEANING PROCEDURES
Beer Flow Control
Filling the Lines the First Time
Handle Operating
1. Turn Beer Flow Control Handle OFF.
Positions
2. Tap fresh keg.
3. Turn Beer Flow Control Handle to CLEAN.
4. Open the beer faucet. When solid beer
5. Turn Beer Flow Control Handle ON. (See
When Tapping Fresh Kegs
1. Remove coupler from empty keg.
Fig. 1
Fig. 2
OFF
ON
2. Turn Beer Flow Control Handle OFF.
2. Tap fresh keg in normal manner.
45
3. Turn Beer Flow Control Handle to CLEAN.
To Restart System
If beer does not flow, first turn the Flow Control
Handle to OFF. (See Fig. 1). Then turn Handle to
the CLEAN position. (See Fig. 3). Wait for five
seconds then turn the Handle to ON position.
(See Fig. 2).
To Clean
Fig. 3
CLEAN
1. Untap Keg in usual manner.
2. Turn Beer Flow Control Handle OFF.
3. Attach cleaning adapter. Use Perlick's
4. Turn Beer Flow Control Handle to
5. After flushing, turn Beer Flow Control
6. To restore service, see above instructions.
(See Fig. 1).
(See Fig. 3).
appears, close the faucet. The line is full.
Fig.2) . The line is full and ready for service.
(See Fig. 1).
position. (See Fig. 3). Wait for five seconds
then turn to ON position. (See Fig. 2).
(See Fig. 1).
single cleaning adapter, No. 43699, if
cleaning from faucet to keg. If two or
more lines are cleaned, use Perlick's
dual cleaning adapter, No. 43702.
CLEAN and clean as usual. (See Fig. 3).
Handle OFF and retap keg. (See Fig. 1).
REPLACEMENT PARTS
7
6
5
3
4
Item ........Part No. ....................Description
1. .......40119 .....................Empty keg Sensor
2. .......43090A ..................Std. Yoke Assy.
3. .......2026 .......................Hex Nut
4. .......2068-1....................Tailpiece
5. .......157R2P..................Washer
6. .......23682-2P ...............Check Valve
7. .......31084-1..................Retaining Screw
8. .......31089-2P ..............."O" Ring (3 per assy.)
9. .......43061.....................Body w/relief valve
10. .......31088-2P ...............Bottom Seal Washer
11. .......31479-1..................Probe Washer
Perlick products are fully guaranteed against defects in both material and
workmanship for a period of one year from date of sale. Defective parts will be
replaced on a no-charge basis, F.O.B. our factory, subject to our inspection. We
are not responsible for parts damaged by alteration, unauthorized service,
accident or abuse. All costs incident to replacement to include freight, labor and/or
loss of sales are incidental to this warranty and must be borne by the user.
1
8
2
9
10
11
Cleaning Adapters
No. 43699
Single Adapter
Warranty
No. 43702
Dual Adapter

Advertisement

loading

This manual is also suitable for:

27500f