Perlick Z2151 Operating Instructions

Smart coupler with empty keg sensor

Advertisement

Quick Links

Troubleshooting
Problem:
Beer flow is slower with Smart Coupler
than with standard Perlick coupler.
Probable Cause:
Beer Flow Control Handle is in CLEAN position.
Solution:
Slowly turn Beer Flow Control Handle to ON position.
Problem:
Beer does not flow after keg is tapped.
Probable Cause:
Smart Coupler has locked up.
Solution:
First, turn Beer Flow Control Handle to OFF position then
turn Beer Flow Control Handle to CLEAN position. Wait
five seconds then turn Beer Flow Control Handle to
ON position.
Probable Cause:
Beer Flow Control Handle is OFF.
Solution:
Turn Beer Flow Control Handle to CLEAN position.
Wait five seconds then turn Beer Flow Control Handle to
ON position.
Probable Cause:
Probe or Smart Coupler is dirty.
Solution:
Clean Smart Coupler.
Probable Cause:
Out of gas.
Solution:
Reestablish gas flow.
Problem:
Excessive foam.
Probable Cause:
Beer temperature too high. Excessive beer flow rate. Beer
is over-carbonated
Solution:
These problems are not caused by the Smart Coupler.
Follow established procedures to correct the problem.
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060
Fax 414-353-7069Toll Free 800-558-5592 • E-Mail: Perlick@Perlick.com • www.Perlick.com
No. 27500F
Smart Coupler with Empty Keg Sensor
please read these instructions before using Perlick's Smart Coupler.
Perlick's Empty Keg Sensor
No. 40119
(Probe Washer Not Included)
Form Z2151
* U.S. Patent #5,630,411
04.06.04
OPERATING INSTRUCTIONS
SMART COUPLER with Empty Keg Sensor
The Smart Coupler* combines a
standard Perlick single-valve keg
coupler with a specially-designed
keg sensor that eliminates the
line loss that normally follows
every empty keg. Fresh kegs can
be drawn off immediately. The
beer lines are always full of beer.
• Saves time
• Reduces beer waste
• Increases beer profits
• Reduces aggravation
IMPORTANT!
To ensure your complete satisfaction,
Retrofitting Single Valve Couplers
Perlick single valve keg couplers can be
retrofitted to function as Smart Couplers.
Simply replace the probe with Perlick's
No. 40119 empty keg sensor.
1. Remove probe washer from
bottom of probe.
2. Remove retaining screw and
yoke assembly.
3. Lift probe out of body.
4. Install Perlick's empty keg sensor.
When replacing probe washer
make sure the "V"-groove surface
faces "down".
Part No.
27500F

Advertisement

loading

Summary of Contents for Perlick Z2151

  • Page 1 These problems are not caused by the Smart Coupler. Follow established procedures to correct the problem. 8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060 Fax 414-353-7069Toll Free 800-558-5592 • E-Mail: Perlick@Perlick.com • www.Perlick.com SMART COUPLER with Empty Keg Sensor No. 27500F...
  • Page 2 11..31479-1...Probe Washer Warranty Perlick products are fully guaranteed against defects in both material and workmanship for a period of one year from date of sale. Defective parts will be replaced on a no-charge basis, F.O.B. our factory, subject to our inspection. We are not responsible for parts damaged by alteration, unauthorized service, accident or abuse.

This manual is also suitable for:

27500f