Troubleshooting
Problem:
Beer flow is slower with Universal Empty Keg Sensor
than with standard Perlick coupler.
Probable Cause:
Beer Flow Control Handle is in CLEAN position.
Solution:
Slowly turn Beer Flow Control Handle to ON position.
Problem:
Beer does not flow after keg is tapped.
Probable Cause:
Universal Empty Keg Sensor has locked up.
Solution:
Turn Beer Flow Control Handle to OFF position.
Wait two or three seconds than slowly turn Beer Flow
Control Handle to ON position.
Probable Cause:
Beer Flow Control Handle is OFF.
Solution:
Slowly turn Beer Flow Control Handle to ON position.
Probable Cause:
Universal Empty Keg Sensor is dirty.
Solution:
Clean Universal Empty Keg Sensor.
Probable Cause:
Out of gas.
Solution:
Reestablish gas flow.
Problem:
Excessive foam.
Probable Cause:
Beer temperature too high. Excessive beer flow rate. Beer
is over-carbonated
Solution:
These problems are not caused by the Universal Empty
Keg Sensor. Follow established procedures to correct
the problem.
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060
Fax 414-353-7069 • Toll Free 800-558-5592 • E-Mail: Perlick@Perlick.com • www.Perlick.com
Universal Empty
Keg Sensor
To ensure your complete satisfaction, please read these instructions
before using Perlick's Universal Empty Keg Sensor.
Form Z2148EMU
* U.S. Patent #5,630,411
08.20.04
INSTALLATION AND OPERATING INSTRUCTIONS
UNIVERSAL EMPTY KEG SENSOR
No. 43739
IMPORTANT!
Part No.
43739
The Perlick Universal Empty
Keg Sensor shuts off the flow
of beer when the keg empties.
With the line full of beer, the
foaming and resulting beer
waste from changing kegs is
eliminated.

Advertisement

loading

Summary of Contents for Perlick Z2148EMU

  • Page 1 Keg Sensor. Follow established procedures to correct the problem. 8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060 Fax 414-353-7069 • Toll Free 800-558-5592 • E-Mail: Perlick@Perlick.com • www.Perlick.com INSTALLATION AND OPERATING INSTRUCTIONS No. 43739 Universal Empty...
  • Page 2 COUPLER Warranty Perlick Products are fully guaranteed against defects in both material and workmanship for a period of one year from date of sale. Defective parts will be replaced on a no-charge basis, F.O.B. our factory, subject to our inspection. We are not responsible for parts damaged by alteration, unauthorized service, accident or abuse.