Philips Fisio 820 Service Manual page 34

Cellular telephone
Hide thumbs Also See for Fisio 820:
Table of Contents

Advertisement

Départ. Technical support- CM640
PHILIPS Consumer
Communications
Centre du Mans
Advanced autotests (used generally for troubleshooting)
Press MENU key to display "PAGE SELECTION."
PRESS Key "1" to change test page to "01", then press
(default test page is 00)
Key
Functional test
ANTENNA TEST
7
Rx Power Level
8
Hand Free Carkit test
0
Defenses Code
#
8.1.4
If any of these steps failed functional, please refer to Chapter 10.
8.1.5
Perform visual check on battery connectors, car kit connectors and casing. If corrosion or deform send to
NSC for repair.
8.1.1
If the product is good, it is considered as a NFF (No Fault Found) product.
All the NFF products must be directly returned to the customer.
 PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Service Repair Support
Observation
" ANTENNA TST"
" Tx Level 10
" CHANNEL 0055
To switch DCS / GMS/ EGSM, press "C" key to toggle
Use to detect Receiving Channel and its power
level
Use this with PHILIPS headset to test the
auxiliary test
Display shows
Defenses 02
Bloc. 02 TAT5
Block B5B401C0
Use this to read out software hang issues or
drop call or any issue relating to network as
well.
COMPANY RESTRICTED
VY-V-640-82x
Page : 34 of 71
Langue : EN
Date : 25/02/03
.
"
(use keys 2 & 8 to change level)
"
(use keys 4 & 6 for channel
VY-V-640-82x
selection)

Advertisement