Loosen the screws of the grinder dial with an Allen
wrench (2.5mm).
Remove the grinder dial.
Unscrew the bracket of the upper burr. Please note that
it may take some force to do so.
Clean the burrs and the threads with a brush. You may
use a vacuum cleaner as well.
Make sure that everything is clean when re-assembling
the parts. There should be no coffee grounds remaining
on the threads. Otherwise you will not be able to put
the parts back together again correctly.
Re-assemble the grinder and re-adjust the grinding
level.
7

TIPPS AND TROUBLESHOOTING

Should a bean become stuck in the grinding mechanism, you may easily fix this yourself.
1
Adjust the grind to a coarser degree. Turn the grind adjuster counter-clockwise by two full turns.
2
Press the portafilter against the grinding button and grind coffee. The stuck beans should now come loose.
3
Re-adjust the grind.
In case the grind setting of your grinder changes autonomously after many grinding procedures, it is most likely that
vibrations during grinding have caused the bracket of the grind level adjuster to become loose. Please proceed as
follows to correct the problem:
1
Switch the grinder off and unplug the electrical cord.
2
Loosen both screws (2.5mm Allen wrench), that are, or were, holding the grind adjustment bracket.
3
Position the bracket as close to the gear wheel as possible and tighten both screws again.