Pentair Pool Products 200K BTU/HR Installation And User Manual page 37

Pool and spa heater 120/240 vac natural gas/lp gas
Hide thumbs Also See for 200K BTU/HR:
Table of Contents

Advertisement

Pool Heater Electrical Schematic Ladder Diagram
L1
VAL
THERMISTOR
SENSOR
LADDER DIAGRAM
120/240
VAC
IGNITER
L1
S1
F2
F1
120/240
VAC
24 VAC
OPERATING
CONTROL
24 VAC
24 VAC
LOGIC
24V
WATER
HI
LIMIT
PRESSURE
SWITCH
SWITCH
COM NO
AGS
SWITCH
STACK FLUE
SENSOR
NOTES:
1.)
L1
L2
F1
F2
S1
S2
GND
IND
VAL
ARE CONNECTED ON THE IGNITION MODULE.
2. )
PIN AND SOCKET CONNECTOR.
3. )
IF ANY OF THE ORIGINAL WIRES AS SUPPLIED
WITH THE APPLIANCE MUST BE REPLACED,
THEY MUST BE REPLACED WITH TYPE 105C
OR ITS EQUIVALENT.
37
L2
S2
L2
BLOWER
GND
CLASS II
TRANSFORMER
GND
AIR
FLOW
SWITCH
TH
IND
GAS VALVE
24 VAC
AND TH

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents