9. TWIN 60 Hz (NTSC) Mode

1) Enter the NTSC monoscope signal, and set in the service
mode.
2) Press "
(TWIN)" button on the commander to set the
TWIN mode.
3) Confirm and set the following data.
Condition :
Category
Item
GEO
00
01
02
03
04
05
07
08
09
0A
0B
0C
15
MID
00
01
11
12
4) Select the category "GEO" and the item "05 HPS", and ad-
just the horizontal position.
H1
H1 – H2 = ± 0.1 sq.
5) Press "
(MUTE)"+"-" buttons on the commander to
write the data to the NVM.
KP- ES43HK1/ME1/MN1/SN1, ES48HK1/ME1/MN1/SN1,
Data
VSZ
VPS
VLN
SCO
Same as
HSZ
DRC1250
HPS
60 Hz (NTSC)
PAP
mode
UPN
LPN
TRZ
AGL
07
BOW
07
VSC
22
HPH
6F
VPH
2E
TMP
01
TSP
00
H2
ES53HK1/ME1/MN1/SN1,

10.INDEX 60 Hz (NTSC) Mode

1) Enter the NTSC monoscope signal, and set in the service
mode.
2) Press "PROGR INDEX" button on the commander to set the
INDEX mode.
3) Confirm and set the following data.
Condition :
Category
GEO
MID
4) Select the category "GEO" and the item "05 HPS" to adjust
the horizontal position, and select the item "01 VPS" to ad-
just the vertical position.
H1
5) Press "
(MUTE)"+"-" buttons on the commander to
write the data to the NVM.
– 71 –
ES61HK1/ME1/MN1/SN1K
Item
Data
00
VSZ
01
VPS
02
VLN
03
SCO
Same as
04
HSZ
DRC1250
05
HPS
60 Hz (NTSC)
07
PAP
mode
08
UPN
09
LPN
0A
TRZ
0B
AGL
07
0C
BOW
07
15
VSC
22
00
HPH
6C
01
VPH
2D
V1 – V2 = ± 0.1 sq.
H2
H1 – H2 = ± 0.1 sq.
RM-961
V1
V2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents