Advertisement

Check out what else you can get from
Martindale:
16th Edition Testers
Accessories
Calibration Equipment
Continuity Testers
Electricians' Kits
Environmental Products
Full Calibration & Repair
Service
Fuse Finders
Digital Clamp Meters
Digital Multimeters
Labels
Microwave Leakage Detectors
Motor Maintenance
Equipment
Trusted by Professionals
Martindale Electric Company Limited
Metrohm House, Penfold Trading Estate, Imperial Way,
Watford WD24 4YY, UK
Tel: +44(0)1923 441717 Fax: +44 (0)1923 446900
E-mail: sales@martindale-electric.co.uk
Website: www.martindale-electric.co.uk
© Martindale Electric Company Ltd. 2008
Registered in England No. 3387451.Rev 3 LITHPAT600
Multifunction Testers
Non-trip Loop Testers
Pat Testers & Accessories
Phase Rotation Testers
Proving Units
Socket Testers
Thermometers & Probes
Test Leads
Voltage Indicators
Specialist Metrohm Testers
(4 & 5kV)
Specialist Drummond Testers
HPAT600
HANDYPAT
I
NSTRUCTION
M
MARTINDALE
Trusted by Professionals
ANUAL
E L E C T R I C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HPAT600 and is the answer not in the manual?

Questions and answers

Summary of Contents for MARTINDALE HPAT600

  • Page 1 Watford WD24 4YY, UK Tel: +44(0)1923 441717 Fax: +44 (0)1923 446900 MARTINDALE E-mail: sales@martindale-electric.co.uk Website: www.martindale-electric.co.uk E L E C T R I C © Martindale Electric Company Ltd. 2008 Trusted by Professionals Registered in England No. 3387451.Rev 3 LITHPAT600...
  • Page 2 Caution - use only the battery type specified MEANING OF SYMBOLS: Battery Life: Fully charged, minimum 600 complete tests, stored to memory. The HPAT600 will operate fully Equipment complies with relevant EU Directives from the battery charger in the event of discharged...
  • Page 3: Table Of Contents

    Specification MARTINDALE Thank you for buying one of our products. For safety HPAT600 and full understanding of its benefits please read this E L E C T R I C manual before use. Technical support is available HandyPAT from 01923 441717 and support@martindale-electric.co.uk.
  • Page 4 3.12 Earth Continuity/Insulation Failure 3.13 Simulated Load Current Hi Martindale shall not be liable for any special, indirect, 3.14 Testing of 110V appliances incidental or consequential damages or losses, including loss of data, arising from any cause or theory.
  • Page 5 4.3 Cleaning immediately. The unit may be cleaned using a soft dry cloth. Do not use moisture, abrasives, solvents, or detergents, which Unpack the HPAT600 and check that you have the can be conductive. following accessories: Instructions 4.4 Repair & Service...
  • Page 6 Ensure the HPAT600 is disconnected from any IEC Lead Test possible voltage sources and the HPAT600 is powered The HPAT600 can also be used to check IEC leads and off before removing the battery cover. extension leads for earth continuity, insulation, and Do not fit non-rechargeable batteries.
  • Page 7: General Operation & Functions

    Undertake a test sequence as appropriate for the appliance (See 3.4 to 3.9). Warning Do not use the HPAT600 if the battery cover is not fitted. NOTE: The TL157 has a special configuration of internal connections to enable the safe testing of Earth...
  • Page 8: Power On/Off

    Repeat Hold down the red power button for at least 1 second to and pressing OK. power on the HPAT600. The HPAT600 will power on at the last settings used and will display the SELECT TEST screen. Abort Test...
  • Page 9: Display Indicators

    'FAIL' for the Flashes to indicate battery charger is connected to fuse check and simulated load test due to the nature of the HPAT600 and powered (Refer to 2.24). their circuitry. When flashing indicates the battery is charging.
  • Page 10: Press Button Description

    3.10 Extension Lead Testing Always refer to and perform 3.2 before proceeding To test extension leads the HPAT600 IEC Lead Test is used with connections as detailed below. Refer to 3.3 (IEC Lead Test). A Martindale EX332 IEC mains lead (or similar) is required to perform extension lead tests.
  • Page 11 CLASS II Selects the Class II test sequence. Result of Test SHIFT INS II Selects the Class II Insulation test as a At the end of the test the HPAT600 will display 'PASS' single test. or 'FAIL' to indicate the result of the test. The measurement result is also displayed.
  • Page 12: Contrast Adjustment

    Result of Test If required the display contrast can be adjusted at power At the end of the test the HPAT600 will display 'PASS' or up. To enable the contrast adjustment hold down the 'FAIL' to indicate the result of the test. The measurement SHIFT and ON/OFF buttons simultaneously at power-up.
  • Page 13: Menu

    Press SHIFT and INS I (CLASS I) to select the Class I insulation test and display the diagram screen. 2.10 Null of Test Probe Lead Resistance (Class I Press OK for the HPAT600 to display the test screen Earth Continuity only) and perform the Class I insulation measurement.
  • Page 14: Setting User Specified Pass Levels

    If the null is successful, NULL will be displayed on the Testing in Manual Mode large 4 digit display and the HPAT600 will return to the Press SHIFT and EARTH (LEAD) to select the Class SELECT screen. I earth continuity test and display the diagram screen.
  • Page 15: Setting Auto/Manual Test Mode

    2.15 Memory Full Screen Class I Test If the HPAT600 memory is full when attempting to save Connections test data, the MEMORY FULL screen will be displayed. To proceed from this screen press OK. It will be necessary to delete some or all of the memory locations in order to save any further test data.
  • Page 16: Recalling Test Data From Memory

    Result of Test When recalling stored test data (Refer to 2.16) the At the end of the test the HPAT600 will display the stored test data in any memory location may be deleted value of the simulated load test current and the individually.
  • Page 17: Deleting All Test Data In Memory

    2.19 Deleting All Test Data in Memory Result of Test To delete all test data stored in all memory locations At the end of the Class II appliance test the HPAT600 enter the MENU screen, use to select Del. All will display 'PASS' or 'FAIL' to indicate the overall result Memory.
  • Page 18: Resetting To Default Settings And Pass Levels

    Reset to Def. and press instance of exposed metalwork, it is advisable to connect OK. All defaults will now be set and the HPAT600 will the test probe to each in turn and perform additional return to the SELECT TEST screen.
  • Page 19: Charging Batteries

    At the end of the Class I appliance test the HPAT600 will is being charged. When the battery is fully charged the display 'PASS' or 'FAIL' to indicate the overall result of the sign will become continuous.
  • Page 20: Auto Or Manual Test Mode

    If all visual and fuse checks pass, select Pass all and will abort the test. press OK for the HPAT600 to display the test screen and perform the fuse check. In the Auto test mode, for the experienced operator, the If 'FAIL' is displayed after the fuse check, refer to 3.11.
  • Page 21: Preliminary Checks And Set Up

    Visually inspect the extension lead socket for any Refer to the Class I connection diagram below. damage. Plug the appliance mains plug into the HPAT600 front Check that the fuse in the plug is of the correct panel mains socket (1).
  • Page 22: Iec Lead Test

    Always refer to and perform 3.2 before If all visual and fuse checks pass, select Pass all and proceeding press OK for the HPAT600 to display the test screen and perform a lead earth continuity measurement. The following are performed:-...