Configure Dcb Policies; Apply Policies To Switch Ports; Save Configuration; Configure Additional Switches - Dell S5000 Configuration Manual

Data center switch
Hide thumbs Also See for S5000:
Table of Contents

Advertisement

FTOS (conf-if-vl-vlan-id*)#tagged tengigabitethernet 0/0-47
Note: For the previous command, you must supply a valid range of populated ports. For example, if only
two Ethernet modules are installed, then the valid range would be: tengigabitethernet 0/0-23
FTOS (conf-if-vl-vlan-id*)#tagged port-channel 1
FTOS (conf-if-vl-vlan-id*)#exit
3.5

Configure DCB policies

FTOS(conf)#dcb-map profile-name
FTOS(conf-dcbmap-profile-name*)#priority-group 0 bandwidth 50 pfc off
FTOS(conf-dcbmap-profile-name*)#priority-group 1 bandwidth 50 pfc on
Note: The sum of the bandwidth percentages must be equal to 100.
FTOS(conf-dcbmap-profile-name*)#priority-pgid 0 0 0 0 1 0 0 0
FTOS(conf-dcb-profile-name*)#exit
3.6

Apply policies to switch ports

FTOS(conf)#interface range tengigabitethernet 0/0 – 47
FTOS(conf-if-range-te-0/0-47)#dcb-map profile-name
FTOS(conf-if-range-te-0/0-47)#exit
FTOS(conf)#interface range fortyGigE 0/48 - 60
FTOS(conf-if-range-fo-0/48-60)#dcb-map profile-name
FTOS(conf-if-range-fo-0/48-60)#exit
FTOS(conf)#exit
3.7

Save configuration

FTOS#copy running-config startup-config
3.8

Configure additional switches

Repeat the commands from Section 3 to configure DCB on additional switches.
12
SCG1007
Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents