BIOS BD401 Instruction Manual

BIOS BD401 Instruction Manual

Wrist blood pressure monitor

Advertisement

Wrist
blOOD pRESSuRE mOnITOR
with BP Advisor™ Technology
InSTRuCTIOn
manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BD401 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BIOS BD401

  • Page 1 Wrist blOOD pRESSuRE mOnITOR with BP Advisor™ Technology InSTRuCTIOn manual...
  • Page 2: Table Of Contents

    About Blood Pressure Normal Blood Pressure Values Common Blood Pressure Questions and Answers What is mean arterial pressure (MAP)? Getting Started About the BD401 About the LCD Screen Inserting the Batteries Discontinuing a Measurement Using the Device Setting Date, Time, Language And Measurement Units Obtaining Accurate Measurements 4.2A Before Measuring...
  • Page 3: Introduction

    “recommended for clinical and home use”, this is the highest grading available for blood pressure monitors. Please refer to BHS website http://www. bhsoc.org/bp_monitors/automatic_wrist.stm. Before using the BD401, please read this instruction manual carefully and keep it in safe place. 1.2 Important Information...
  • Page 4: About Blood Pressure

    • Morning Hypertension ( > 135 / 85 mm Hg): Recently, several studies have identified elevated cardiovascular risks (heart failure, stroke, angina) associated with “morning hypertension”. There is a typical rise in blood pressure during the physiological changes from sleep to arising for the day. •...
  • Page 5: Normal Blood Pressure Values

    important organs (heart, brain, muscles) can be the result. Furthermore, with long-term increased blood pressure values, the heart will become structurally damaged. • There are many different causes of the appearance of high blood pressure. We differentiate between common primary (essential) hypertension, and secondary hypertension.
  • Page 6: Common Blood Pressure Questions And Answers

    Further information If your values are mostly “normal” under resting conditions but exceptionally high under conditions of physical or psychological stress, it is possible that you are suffering from so- called ”labile hypertension”. In any case, please discuss the values with your doctor. Correctly measured diastolic blood-pressure values above 120mmHg require immediate medical treatment.
  • Page 7: What Is Mean Arterial Pressure (Map)

    Blood pressure is lower than normal: • after consuming alcohol • after taking a bath b) Why is the doctor’s reading different from the reading taken at home? Your blood pressure can vary due to the environment (temperature, nervous condition). When measuring blood pressure at the doctor’s office, it is possible for blood pressure to increase due to anxiety and tension.
  • Page 8: Getting Started

    3.0 Getting Started 3.1 About the BD401 1. TALK / VOLUME BUTTON 1. WRIST CUFF 2. LCD 2. BATTERy COMPARTMENT 3. ON / OFF BUTTON 4. SPEAKER 5. USER 1 / UP ARROW BUTTON 6. USER 2 / DOWN ARROW BUTTON 7.
  • Page 10: Inserting The Batteries

    Used batteries can be harmful to the environment, and should not be thrown out with household trash. 4. Using The Device This section describes how to get the maximum benefit from your BD401 blood pressure monitor. Follow the instructions carefully to get an accurate measurement of your blood pressure and pulse rate.
  • Page 11: Setting Date, Time, Language And Measurement Units

    4.1 Setting Date, Time, Language And Measurement Units It is important to set the clock before using your blood pressure monitor, so that the correct time stamp can be assigned to each record that is stored in the memory. 1. When the unit is off, press and hold SET for 2 seconds to enter the setting mode. 2.
  • Page 12: Obtaining Accurate Measurements

    4.2 Obtaining Accurate Measurements Your blood pressure can vary based on numerous factors, physiological conditions, and your surroundings. Follow these guidelines to obtain accurate and error-free measurements of your blood pressure and pulse rate. 4.2A Before Measuring • Avoid eating, smoking as well as all forms of exertion directly before the measurement. All these factors influence the measurement result.
  • Page 13: C Choose Your Measurement Position

    d) Position the edge of the cuff about 0.4 inches (1cm) from the bottom of your palm. e) Fasten the wrist cuff around your wrist, leaving no extra room between the cuff and your skin. If the cuff is too loose, the measurement will not be accurate.
  • Page 14: Recalling Measurements Stored In Memory

    NOTE: This unit can intelligently adjust the cuff pressure and inflate to a higher pressure level (>180 mmHg) when needed. 2. Your systolic and diastolic pressure readings will flash on the LCD, followed by MAP and pulse per minute readings every 2 seconds. At the same time, your measurement results and the blood pressure classification will also be announced.
  • Page 15: Deleting A Measurement Record From Memory

    NOTE: • The most recent record (1) is shown first. Each new measurement is assigned to the first (1) record. All other records are pushed back one digit (e.g., 2 becomes 3, and so on), and the last record (60) is dropped from the list. •...
  • Page 16 3. Press and hold SET for 2 seconds to delete the latest recorded measurement for User 1 or User 2. After you have confirmed deleting the latest record, the screen shows “dEL ONE”. 4. If you decide to abort the delete action instead, press to go back to the main screen.
  • Page 17: Discontinue A Measurement

    4.6 Discontinue A Measurement If it is necessary to interrupt a blood pressure measurement for any reason (e.g. the patient feels unwell), the ON/OFF button can be pressed at any time. The device then immediately lowers the cuff pressure automatically. 4.7 Voice Playback Of Blood Pressure Measurement The features voice playback during and after blood pressure measurement results, as well as general instructions to help you prepare for taking measurements.
  • Page 18: Troubleshooting

    5. Troubleshooting This section includes a list of error messages and frequently asked questions for problems you may encounter with your blood pressure monitor. If the product is not operating as you think it should, check this list before arranging for servicing. Problem Symptom Check This...
  • Page 19 Err 6 shows on the Deflation period Movement can affect display was too long the measurement. Relax for a moment and then measure again EExx shows on the A calibration error Retake the display occurred measurement.If the problem persists, contact the retailer or our customer service department for further assistance.
  • Page 20: Care And Maintenance

    6. Care And Maintenance a) Do not expose the device to either extreme temperatures, high humidity, dust or direct sunlight. If the unit has been stored at very low or freezing temperature, allow to reach room temperature before using it. b) Clean the device with a soft, dry cloth.
  • Page 21: Lifetime Guarantee

    The cuff is warranted for two years. The warranty does not cover damage from misuse or tampering. If you have questions regarding the operation of your monitor call the BIOS Diagnostics Blood Pressure Hotline: ™...
  • Page 22: Reference To Standards

    8. Reference To Standards Device standard: Device corresponds to the requirements of the standard for non-invasive blood pressure monitors: AAMI/ANSI SP10 IEC 60601-1 IEC 60601-1-2 EN1060-1 EN1060-3 EN1060-4 Electromagnetic compatibility: Device fulfills the stipulations of the International standard IEC 60601-1-2 Readings taken by the blood pressure monitor are equivalent to those obtained by a trained observer using the cuff and stethoscope auscultation method.
  • Page 23: Technical Specifications

    9. Technical Specifications Weight: 6.3 oz (180g) without batteries Size Height x Width x Depth: 3.5”(H) x 3.4”(W) x 1.2”(D) (90 x 86 x 30.8 mm) Storage Temperature: 4°F to 140°F (-20°C to 60°C) Humidity: 10% to 83% relative humidity Operation Temperature: 50°F to 104°F (10°C to 40°C) Display:...