How To: Align Mouth Motor & Sensor - Bay Tek Games Arctic Chomp Service Manual

Table of Contents

Advertisement

To Purchase This Item, Visit BMI Gaming | www.bmigaming.com | (800) 746-2255 | +561.391.7200
HOW TO: ALIGN MOUTH MOTOR & SENSOR
This black plastic blocks sensor to position mouth. (Open



HOW TO: CHANGE SENSOR
1.) Remove 2 sets of
nuts and bolts



Motor will go forward and backward to open and close mouth.
Encoder Wheel (Part # AACA3258)
or Closed)
The mouth is closing when sensor is being blocked.

The mouth is opening when sensor is clear.
Top of wheel rotates toward back of game and down.
Important that "Motor Side" is installed toward motor.
2.) Remove 4 screws in
motor mounting plate.
Notch Sensor (Part # AACB4401)
This sensor "sees" the notches of the notch wheel.
Game keeps track of mouth position with this sensor.
3.3 Volts DC normally between black and white wires.
Drops to 0 Volts DC when notch is blocking sensor.
Mouth Motor (Part # AAMO4101)

12 Volt DC motor.

5-6 Ohms
3.) Remove motor assy
from game.
26
4.) Remove set
screw in hub.
4.) Replace faulty sensor
and re-assemble parts.

Hide quick links: