Getting To Know Your TC7000 camera designed and certified Getting Started A Guide To Charging Your TC7000 specifically for use in hazardous A Guide To Your Home Screen (explosive) atmospheres. Focus...
T7000 – Intrinsically Safe Thermal Imaging Camera GETTING TO KNOW YOUR TC7000 Neck Strap Points Wrist Strap Points Image Save Menu Key Level + RFID Scanner USB Connection Point Power Switch Span + Level - Focus Ring 135˚ Swivel Lens...
T7000 – Intrinsically Safe Thermal Imaging Camera GETTING STARTED A GUIDE TO CHARGING YOUR TC7000 Check the contents of your TC7000. For comparative thermography, do not Remove the battery from the battery Insert the battery pack into the camera paying...
Maximum Image Temerature CREATING A THERMAL IMAGE Temperature Scale Minimum Image Temperature • Switch on the TC7000 by pressing and Battery Charge Indicator holding the power switch for at least 3 seconds. • Ensure auto Level/Span is enabled. Ambient Temperature Selected (See Settings section on P.13)
This is followed by the selected through the menu button. Press this or deselect all of the display settings. (See option for the TC7000 to scan for an RFID once to display 6 icons. detailed Settings section on P.13) tag.
T7000 – Intrinsically Safe Thermal Imaging Camera RFID ANALYSIS There are three settings in the analysis menu: • When an RFID tag is located an RFID details menu will be displayed which shows the hexadecimal identification of the RFID tag. •...
T7000 – Intrinsically Safe Thermal Imaging Camera SETTINGS PARAMETERS There are 10 icons in the Settings Menu There are 5 icons in the parameters menu all allowing the user to input temperature measurement parameters to increase measurement accuracy. The Scale Icon toggles the display of the temperature colour scale.
T7000 – Intrinsically Safe Thermal Imaging Camera LEVEL/SPAN STORING AND ANALYSING IMAGES • Two settings are fundamental to obtaining • The Image Save Button on top of the an effective thermal image, the first is clear handgrip is used to store images (except focus and the second is the correct thermal when periodic save is enabled).
Page 10
T7000 – Intrinsically Safe Thermal Imaging Camera Certificate Information ATEX / IECEx Certificate No TRAC12ATEX0037X / IECEx TRC 12.0019X • ATEX / IECEx Certificate Types Ex ib IIC T4 Gb Tamb -10°C to +40°C (Vapor) • Ex ib IIIC T200°C Db Tamb -10°C to +40°C (Dust) •...
T7000 – Intrinsically Safe Thermal Imaging Camera TEN SUGGESTIONS FOR THERMOGRAPHY BEST PRACTICE Ensure that the electrical or mechanical Observe a scene from different angles to Always store images and relate them where system you are imaging is running fully loaded minimise thermal reflection as an unusual possible to visible images when building a to highlight thermal anomalies.