If installation at both ends of a hop are complete except for connecting to customer inputs/outputs and it is
desirable to have an alarm-free system, alarm reporting on the incomplete connections can be disabled
temporarily through provisioning. You can communicate over the hop even if you do not have the radio connected
to customer DS1 inputs; however, you will alarm unless you select OFF to disable INSERT CHANNEL (located on the
USI DS1 Facilities screen) for all equipped lines. Disabling the DS1 insert function disables both the lines and
alarm reporting for the lines. After all customer connections are complete, alarm reporting can be restored to
normal. To restore alarm reporting to normal, set INSERT CHANNEL on DS1 Facilities screen to ON.
The term "LINE" is used to describe an input/output signal at DS1/E1 rate (1.544 MB/S 2.043 MB/S). The
term "CHANNEL" is used to describe a multiplexed signal, at a higher rate than DS1/E1.
channel is output of multiplexer circuit. The dropped channel is input to demultiplexer circuit. The multiplexer
and demultiplexer circuits are located on I/O interface module.
SELECTING ON INSERTS LOCAL DATA AND TURNS ON
ALARM REPORTING. SELECTING NM (NOT MONITORED),
DEFAULT SETTING, INSERTS LOCAL AIS DATA BUT TURNS
OFF ALARM REPORTING. SELECTING
DATA INSERT AND TURNS OFF ALARM REPORTING.
SELECT ON FOR ALL LINES IN USE AT A TERMINAL OR DROP-
AND-INSERT REPEATER. SELECT NM FOR ALL LINES NOT
USED AT A TERMINAL AND DROP-AND-INSERT REPEATER.
SELECT
FOR ALL LINES AT A NON-STANDBY THROUGH
OFF
REPEATER, OR SELECT
NM FOR LINES 5 THROUGH 16 AT A PROTECTED REPEATER.
LINES
INSERT CHANNEL
DROP CHANNEL
LINE CODING
AIS INHIBIT
LINE
INSERT CHANNEL
DROP CHANNEL
LINE CODING
AIS INHIBIT
AIS SIGNAL
SELECT ALL 1s OR ALL 0s AIS
DATA FORMAT FOR ALL LINES.
SELECT AMI OR B8ZS CODING
FOR EACH DS1 LINE. E1 LINE
CODING IS ALWAYS HDB3.
4-10
TURNS OFF LOCAL
OFF
FOR LINES 1 THROUGH 4 AND
OFF
1
2
3
ON
ON
OFF
OFF
ON
ON
OFF
OFF
AMI
AMI
AMI
AMI
OFF
OFF
OFF
OFF
9
10
11
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
AMI
AMI
AMI
AMI
OFF
OFF
OFF
OFF
ALL ONES
FOR ALL DS1 LINES, SELECT RANGE
THAT MATCHES ACTUAL DISTANCE
TO CROSS-CONNECT 0-150 (TEO OFF),
150-330 (TEO ON), 330-480 (TEO OFF) OR
480-660 (TEO ON) FT. FOR E1, NO DIS-
TANCE IS DISPLAYED.
Figure 4-4 DS1/E1 Facilities Provisioning
Note
Note
SELECT ON TO DROP
ALL LINES OR OFF TO
DISABLE ALL LINES
AND ALARMS.
FOR EACH LINE, SELECT
ON TO DROP LINE OR OFF
TO DISABLE LINE AND
ALARMS.
4
5
6
OFF
OFF
OFF
OFF
OFF
OFF
AMI
AMI
AMI
OFF
OFF
OFF
12
13
14
15
OFF
OFF
OFF
OFF
OFF
OFF
AMI
AMI
AMI
OFF
OFF
OFF
DS1 LINE LENGTH
SELECT ON OR OFF
WHEN
.
SET TO ON, AIS INSERTION
IS INHIBITED ON SELECTED
DS1/E1.
The inserted
SELECT ON TO
INSERT ALL
LINES OR OFF TO
DISABLE ALL LINES
AND ALARMS.
SELECT AMI
OR B8ZS
CODING FOR
ALL DSI LINES
7
8
Select All
OFF
OFF
AMI
OFF
16
Select All
OFF
OFF
AMI
OFF
0-150
SELECT ON TO INHIBIT AIS
INSERTION ON ALL LINES.
SELECT OFF TO ENABLE
AIS INSERTION ON ALL
LINES.