2-8. KEY PCB check mode
1. While holding the PLAY, STOP, F FWD and REW key
pressed, turn the power ON. In this case, all LED's light.
2. Press the STOP, F FWD, REW, PLAY or RECORD key.
All LEDs go out.
3. When each key is pressed, the corresponding LED lights.
2-9. How to use the built-in oscillator
1. Enter the test mode.
2. Select the menu group 2 in the menu screen.
3. Move the cursor to "Sine Osc" and press ENTER key.
4. Use the § and ¶ keys to select the output frequency (OFF,
440 Hz, 1 kHz, 10 kHz, 20 kHz, 20 Hz, wite noise).
(The level is full scale.)
2-10. Removing the FRONT MPU
As shown in Fig. 2-1, hold the FRONT MPU (KEY PCB:U6)
with the PLCC EXTRACTOR (P/N: 16910101) to remove it.
2-11. Removing the SYS ROM
Detach the socket cover to remove the SYS ROM (SYS
PCB : U011). To remove the socket cover, slide it as shown in
Fig. 2-2.
Fig. 2-1
PLCC EXTRACTOR
U6
2-8. KEY PCBチェックモード
1. PLAYキー+STOPキー+F FWDキー+REWキーを押し
ながら電源をONにするとチェックモードに入る。
このとき、LEDが全灯する。
2. STOP, F FWD, REW, PLAY, RECORDのいずれかのキー
を押すと、LEDが全て消灯する。
3. その後、それぞれのキーを押すと、そのキーに対応す
るLEDが点灯する。
2-9. 内臓オシレーターの使用方法
1. テストモードにする。
2. メニュー画面で、メニューグループ2を選択する。
3."Sine Osc"にカーソルを合わせてENTERキーを押す。
4. § キー/¶ キーで、出力する周波数(OFF, 440Hz,
1kHz, 10kHz, 20kHz, 20Hz, White noise)を選択する。
(レベルはフルスケール)
2-10. FRONT MPUの外し方
図2-1のように、PLCC EXTRACTOR (品番:16910101) で
FRONT MPU (KEY PCB: U6)を挟んで取り外します。
2-11. SYS ROMの外し方
SYS ROM (SYS PCB:U011)はソケットカバーを取り外す
ことにより、外すことができます。
ソケットカバーは、図2-2のようにスライドさせることに
より取り外します。
Detach
−8−
Attach
Fig. 2-2