5-7. RF level check

5-7-1. Checks in Normal mode
1. Connect the oscilloscope's CH1 to TP3 (RF A-HEAD) on the
RF PLAY PCB and CH2 to TP601 (SWH) on the SYS PCB.
2. Set the oscilloscope's CH1 range to 500 mV AC, 2 msec.
3. Set the oscilloscope's CH2 range to 5 V DC, and (-) trigger.
4. Play the test tape MTT-88101.
5. Observe the waveform at TP3 (RF A-HEAD) , and see that
the following standard is satisfied.
Standard value (see Fig. 5-3):
B, C (minimum) : 1000 mV or more
B/A, C/A : 80 % or more
6. Next, set the oscilloscope's CH2 to (+) triggering.
7. Connect the oscilloscope's CH1 to TP4 (RF B-HEAD) on the
RF PLAY PCB, then observe the B-HEAD waveform, see
that the standard is satisfied:
5-7-2. Checks in Confidence mode
Set the Confidence mode on, and perform the same check as dis-
cussed in 5-7-1.
ATF
SUB DATA
CH
CH
1/2
3/4
CH 1
B
A
820 µs
A-HEAD
CH 2
Fig. 5-3
−39−
5-7. RFレベル確認
5-7-1. ノーマルモードでの確認
1. オシロスコープの CH1を RF PLAY PCBの TP3 ( RF A-HEAD)
に、CH2をSYS PCBのTP601 (SWH) に接続する。
2. オシロスコープの CH1のレンジをAC 500mV, 2msecに
セットする。
3. オシロスコープの CH2のレンジをDC 5Vにセットし、
(−) トリガーとする。
4. テストテープ MTT-88101を再生する。
5. TP3 (RF A-HEAD) の波形 を観測し、下記の規格値を満
足すること。
規格値(図5-3参照)
B, C(最小部): 1000mV以上
B/A, C/A
: 80%以上
CH
CH
5/6
7/8
C
570 µs
B-HEAD
6. 次にオシロスコープの CH2を (+) トリガーにセットする。
7. オシロスコープの CH1を RF PLAY PCBの TP4 ( RF B-HEAD)
に接続して B-HEADの波形を観測し、A-HEADと同様
に規格値を満足すること。
5-7-2. コンフィデンスモードでの確認
コンフィデンスモードに切換えて、5-7-1項と同様の確認
を行う。