10°C HEAT Operation
z
The room temperature can be set to go no lower than 10°C,
thus ensuring that the room does not get too cold when not occupied.
NOTE:
•
When the room temperature is higher than 10°C, "10°C HEAT" operation will not start. Operation starts and maintains the room
temperature at 10°C when the temperature drops below 10°C.
Powerful operation
z
20 minutes continuous operation by maximum airflow and maximum compressor speed is
possible. Rapid cooling and heating makes the room comfortable quickly.
Normal mode
Powerful
Setting temp.
Economy operation
z
Example : Cooling operation
• Economy operation is energy saving, as the set temperature of indoor unit is shifted by 1°C and
the maximum electric value of the outdoor unit is suppressed.
Economy operation
Set temperature
Normal operation
Control maximum current
Low outdoor air temperature correspondence
z
Corresponds to cooling operation at -10°C outdoor air temperature
Corresponds to heating operation at -15°C outdoor air temperature
Cooling
Heating
-10
to
43
-15
to
°C
Corresponds to maximum 20m long piping
z
"10°C HEAT"
Button
ON
20
°C
10
°C
Time
Shift
setting
temp
Time
24
°C
- (01 - 02) -
Indoor unit
operation
START