Other Operation; Powerful Operation; Settings On Installation; Remote Controller Custom Code Setting - Fujitsu AIRSTAGE ASTH18CNTA Operation Manual

Table of Contents

Advertisement

■ Details on Demand Response mode
DR mode
Description of operation in this mode
DR mode 1
Compressor off.
Electrical energy consumption in 30 minutes:
DR mode 2
50% or less
(compared with rated energy consumption)
Electrical energy consumption in 30 minutes:
DR mode 3
75% or less
(compared with rated energy consumption)
NOTES:
• During the DR mode, the cooling performance may be reduced.
• During the DR mode, only the following operations are valid.
- Turning off the operation by
- Off timer operation
• The Powerful operation is performed within the operable range of
the DR mode.
• During the DR mode, the Filter sign will not display.
• Timer setting error indicator will be prioritized over the DR mode
indicator.
If you have operational issues:
(1) Contact your electricity supplier to check whether they are activating
the DR mode.
(2) Is the air conditioner under the Demand controlling?
Yes
Contact your electricity supplier.
No • Contact Fujitsu General (AUST.) PTY LIMITED. (Refer to
your warranty card.)
or
• Visit our website (www.fujitsugeneral.com.au).

8. OTHER OPERATION

8.1. Powerful operation

In the Powerful operation, the air conditioner will operate at maximum
power and strong airflow to cool down or warm up the room quickly.
Press
to activate/deactivate the Powerful operation.
)
When activated, the indoor unit will emit 2 short beeps.
When deactivated, the indoor unit will emit 1 short beep.
The Powerful operation will be turned off automatically in the following
situations:
• The Powerful operation runs for a certain amount of time and the
room temperature reaches the set temperature in the Cooling or Dry
mode.
• 20 minutes after the Powerful operation has started.
NOTES:
• The airflow direction and the fan speed are controlled automatically.
• The Powerful operation cannot be performed simultaneously with
Economy operation.
• If the wired remote controller (optional) is connected, this function is
restricted.

9. SETTINGS ON INSTALLATION

9.1. Remote controller custom code setting

By setting custom code of indoor unit and remote controller, you can
specify the air conditioner which the remote controller controls.
When two or more air conditioners are in the room and you wish to
operate them separately, set the custom code (4 selections possible).
NOTE: If custom codes are different between the indoor unit and the
remote controller, the indoor unit cannot receive a signal from
the remote controller.
How to set the remote controller custom code
1. Press
until the indicators on the remote controller turn
off.
2. Press down
for more than 5 seconds.
The current custom code will be displayed (initially set to A).
3. Press
the custom code between
A ( ) ↔ B ( ) ↔ C ( / ) ↔D ( ).
* Match the custom code on the display
to the air conditioner custom code.
4. Press
again.
The custom code will be set.
The display will return to the original
display.
• To change the air conditioner custom code, contact authorized
service personnel (initially set to A).
• If you do not press any buttons for 30 seconds after the custom
code is displayed, the displayed custom code is set and the
display returns to the original display.
• Depending on the remote controller, the custom code may return
to A when replacing the batteries. In this case, reset the custom
code as necessary. If you do not know the air conditioner custom
code, try each code until you find the code which operates the air
conditioner.

10. CLEANING AND CARE

• Before cleaning this product, be sure to turn it off and
disconnect all the power supply.
• Before starting operation, make sure that the intake
grille has been shut completely. Incomplete closing
of the intake grille might have an effect on the proper
working or performance of the air conditioner.
• If the filter cleaning involves high-place work, consult
the authorized service personnel.
• Do not touch the aluminum fins of heat exchanger
built-in the indoor unit to avoid personal injury when
you maintain the unit.
• Do not expose the indoor unit to liquid insecticides or
hair sprays.
• Do not stand on slippery, uneven or unstable surfaces
when you maintain the unit.
Air cleaning filters
Intake grille
(Apple catechin filter, Ion deodorization filter)
Air filters
The frequency of the cleaning is as shown in the following table.
What to do
Indoor unit body
Air filter
Apple-catechin filter (UTR-FA16)
(White)
Ion deodorization filter (UTR-FA16-2) Cleaning
(Light blue)
* The air cleaning filters are sold separately. When you replace them,
contact the store of purchase.
En-7
to change
CAUTION
Indoor unit body
Frequency
Cleaning
When you notice
Cleaning
Every 2 weeks
Replacing Every 3 months
Every 3 months
Replacing Every 3 years