KVH Industries TracVision M7 Installation Manual page 30

Master control panel configuration tapered baseplate version
Hide thumbs Also See for TracVision M7:
Table of Contents

Advertisement

A
Wiring 3+ Receivers
To connect three or more receivers to a system
configured for Sky Mexico, follow these steps to
install an Eagle Aspen 501481 multiswitch (KVH
part #19-0573) between the grounding block and
the receivers, as shown in Figure 46.
1. Connect an RF cable from the "RF1"
connector on the grounding block to the
"18V/22KHz" connector on the multiswitch.
2. Connect an RF cable from the "RF2"
connector on the grounding block to the
"13V/22KHz" connector on the multiswitch.
3. Connect the receivers to the individual
outputs of the multiswitch.
4. Connect the receivers to the customer's TVs.
30
Sky Mexico Systems
Figure 46: Multiswitch Wiring - Sky Mexico
RF2
Grounding
Block
RF2
18V/0KHz
13V/0KHz
Power In
SATA
SATA
18VDC/1A
Receivers
1
2
RF1
Ground Wire
Vessel
AC Ground
RF1
18V/22KHz
13V/22KHz
Antenna
18V/22KHz
13V/22KHz
In
SATB
SATB
Multiswitch
3
4
5
6
7
8
Receiver #4
Satellite In
TV ANT/CABLE IN
R
L
OUT TO TV
SATELLITE IN
AUDIO
VIDEO
S-VIDEO
Receiver #3
Satellite In
TV ANT/CABLE IN
R
L
OUT TO TV
SATELLITE IN
AUDIO
VIDEO
S-VIDEO
Receiver #2
Satellite In
TV ANT/CABLE IN
R
L
OUT TO TV
SATELLITE IN
AUDIO
VIDEO
S-VIDEO
Receiver #1
Satellite In
TV ANT/CABLE IN
R
L
OUT TO TV
SATELLITE IN
AUDIO
VIDEO
S-VIDEO
PHONE JACK
PHONE JACK
PHONE JACK
PHONE JACK

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tracvision m7sk

Table of Contents