Operating Instructions
8. Troubleshooting
Follow these guidelines to help solve problems with the
Perdix AI�
8.1. Warning and error displays
The following table shows warnings and errors you may see,
their meaning, and steps to take to solve any problems�
Display
Meaning
No Comms
T1
----
No communications for 30
3042
P
P
Alternates
to 90 seconds�
S
S
I
I
T1
No Comms
----
----
P
P
Alternates
S
S
I
+
I
No communications for
90+ seconds�
Warning
Confirm
AI LOST COMMS
T1
Low Bat
3042
3042
P
Alternates
P
S
S
I
I
+
Low transmitter battery�
Warning
Confirm
AI LOW BATTERY
Tank pressure exceeds
T1
3600
rated pressure by more
P
S
than 10%�
I
T1
682
P
S
Tank pressure has
I
+
fallen below the reserve
Warning
Confirm
pressure setting�
T1 RESERVE PRES.
Page 18
Action to take
See Section 8.2. Connec-
tion problems
See Section 8.2. Connec-
tion problems
Replace the transmitter
battery� See Section 9.1.
Transmitter Battery Re-
placement
Properly set the rated pres-
sure in the AI Setup->Tx
Setup menu�
Be aware that gas is
running low� Begin to end
your dive and perform a
controlled ascent to the
surface�
Display
Meaning
T1
345
P
S
I
+
Tank pressure has fallen
below the critical pressure�
Warning
Confirm
T1 CRITICAL PRES
GTR
T1
GTR is not available when
---
on the surface�
GTR
T1
GTR (and SAC) are not
available for the first
wait
few minutes of a dive�
8.2. Connection problems
If you are seeing "No Comms" errors, follow these steps:
If the "No Comms" is persistent:
•
Check that the proper serial number is entered into the
AI SetupT1/T2 Setup menu�
•
Ensure the transmitter is turned on, by connecting it
to a first stage and turning on the tank valve. Applying
high pressure > 50 PSI (3�5 Bar) is the only way to turn
on the transmitter. The transmitter will power off after 2
minutes of no pressure�
•
Bring the handset within range (3ft / 1m) of the
transmitter� Having the transmitter too close (less than
2 inches / 5 cm) can also cause communication loss�
If the "No Comms" is intermittent:
•
Search for sources of radio frequency (RF)
interference, such as HID lights, scooters, or photo
flashes. Try eliminating such sources to see if this
solves the connection problem�
Action to take
Be aware that gas is
running low� Begin to end
your dive and perform a
controlled ascent to the
surface�
None� GTR will display
during a dive�
None� After a few minutes,
enough data has been
collected for display�
RevA
Need help?
Do you have a question about the SHEARWATER and is the answer not in the manual?
Questions and answers