Rs-232C Command Table - Sharp PN-R556 Operation Manual

Hide thumbs Also See for PN-R556:
Table of Contents

Advertisement

Controlling the Monitor with a PC (RS-232C)

RS-232C command table

How to read the command table
Command:
Command field (See page 34.)
Direction:
W When the "Parameter" is set in the parameter field (see page 34), the command functions as described
R The returned value indicated under "Reply" can be obtained by setting "????", "
Parameter:
Parameter field (See page 34.)
Reply:
Response (Returned value)
* :
"●" indicates a command which can be used in power standby mode regardless of the POWER SAVE MODE
"○" indicates a command which cannot be used in power standby mode when POWER SAVE MODE is set to ON.
"–" indicates a command which cannot be used in power standby mode regardless of the POWER SAVE MODE
Power control/Input mode selection
Function
POWER CONTROL
INPUT MODE SELECTION
38
E
under "Control/Response Contents".
(repeater control) in the parameter field. (See page 34.)
setting.
setting.
Command
Direction
POWR
W
R
INPS
W
R
Parameter
Reply
0
Switches to standby mode.
1
Returns from standby mode.
0 Standby mode
1 Normal mode
2 Input signal waiting mode
0
Toggle change for input mode. Terminals not selected in INPUT SELECT
cannot be selected.
1
DVI-D
2
D-SUB[RGB]
"ERR" when other than RGB is selected for D-SUB of INPUT SELECT.
3
D-SUB[COMPONENT]
"ERR" when other than COMPONENT is selected for D-SUB of INPUT
SELECT.
10
HDMI1
13
HDMI2
14
DisplayPort
21
OPTION
"ERR" when nothing is attached in the expansion slot.
1 DVI-D
2 D-SUB[RGB]
3 D-SUB[COMPONENT]
10 HDMI1
13 HDMI2
14 DisplayPort
21 OPTION
?" or "???+"
Control/Response contents
*