5.2 Engine Monitoring Page

An example of engine monitoring page is illustrated on Figure 7. It can be designed differently for each
EMSIS unit regarding to the wishes of the customer. Additionally, more than one EMS page can be
configured.
The page from Figure 7 shows the following items:
1. engine RPM indicator,
2. airbox temperature,
3. manifold pressure,
4. fuel level with the numeric indication,
5. fuel consumption (fuel flow),
6. engine total time,
7. ampere meter (electrical current meter),
8. system voltage,
9. water temperature,
10. CHT with two sensors and the largest value of both,
11. EGT with several sensors and the largest value of them all,
12. oil temperature,
13. fuel pressure,
14. oil pressure.
Figure 6: Setting pitch.
1
2
1
14
13
12
11
10
9
8
7
Figure 7: EMSIS engine monitoring page.