3-2-2 DISASSEMBLY PROCESS (AO*G30LAT4)
1. Service Panel sub assy removal
Remove the 2 mounting screws.
Remove the SERVICE PANEL by sliding downward.
Hook
(3 places)
2. Top Panel sub assy removal
Remove the 7 mounting screws.
Remove the TOP PANEL upward.
FRONT VIEW
Replaceable Component
Compressor
Accumulator
4-way valve
Solenoid
Thermistor (Compressor temp.)
Thermistor (Discharge temp.)
Thermistor (Outdoor temp.)
Thermistor (Heat exchanger temp.)
Thermistor (2/3-way valve temp.)
Pressure SW
Coil (Expansion valve)
03-15