7. ACTPM removal
Remove the connectors and cords.
Remove the 2 mounting screws.
Remove the ACTPM (Active Filter Module).
Twist 4 times or more
" - " (Black)
" + " (Red)
CN407
F
2 turn the Wire this way
" L2 " (Brown)
Thermistor (Heat sink)
" L1 " (White)
" N1 " (Blue)
" P " (Yellow)
(Refer to VIEW -F)
(Refer to VIEW -F)
Spread the heat dissipation compound
on the other side of ACTPM,
when you exchange ACTPM by the repair.
VIEW - F
03-22