4.
Q528.2E LA
4.3.8
Small Signal Board (SSB)
Refer to next figure for details.
Caution: it is mandatory to remount all different screws at their
original position during re-assembly. Failure to do so may result
in damaging the SSB.
Refer to next figures or details.
1. Unplug the LVDS connector [1].
Caution: be careful, as this is a very fragile connector!
2. Unplug the connectors [2].
3. Remove the screws [3].
4. The SSB can now be taken out of the set, together with the
front shield and the side cover.
5. To remove the shield, remove the screws [4] and lift it of.
6. To remove the side cover remove the screws [5].
7. Release clip [6] and slide the pull the cover sidewards from
the SSB.
1
3
3
2
3
Mechanical Instructions
3
4
4
Figure 4-14 Small Signal Board
3
6
3
4
4
4
4
3
5
3
H_17650_103.eps
180108