INSTRUCTION MANUAL DIGITAL BLOOD PRESSURE MONITOR CH-311B ón. English Español Português Deutsch 0801 - Eng 1 - Downloaded from www.Manualslib.com manuals search engine...
GENERAL REMARKS pressure 6. Measure your blood pressure where the room temperature is about 20°C. DO NOT measure blood pressure when it is too cold (below 10°C) or too hot (above 40°C) in the room. n”. 7. DO NOT try to measure blood pressure immediately after drinking cm to 32 coffee or tea or smoking.
Page 3
ANCE PRECAUTION FOR USE AND MAINTENANCE 15.Be sure to use this unit only for measuring blood pressure. DO NOT use it for any other purpose. or other 16.DO NOT use this unit on an infant. 17.This product uses natural rubber for the rubber bulb. or other The natural rubber may cause any allergic reaction such as itching, g “Exhaust...
IDENTIFICATION OF PARTS d of time; every two Systolic blood pressure display section Diastolic blood pressure display section ral and/or s and the Pulse display section Hole of holding strap Power switch : OFF : ON Pumping bulb 60601-1-2. rdance with way that the ence.
Page 5
HOW TO LOAD BATTERIES Open the battery compartment cover. 1 While pressing the lock section of the battery compartment cover, 2 pull the cover toward you to open. Place the batteries in the compartment. Fit the batteries paying attention to the positive + and negative –...
Page 6
RIES POINTS FOR ACCURATE MEASUREMENT Blood pressure varies with posture, the time of day or numerous other factors. It is recommended to measure blood pressure at the same time each day in the same posture. ■ Measurement in sitting posture 1 Place your arm on a table or similar surface stretching out the portion from the elbow to the hand.
Page 7
HOW TO WRAP THE ARM CUFF Draw the end of the arm cuff metal bar to fit it on the arm and Velcro secure with Velcro. • Carefully place the arm taking care to obtain adequate tightness, not too tight or loose. Adequate tightness is obtained when you can place a finger between the cuff and your arm.
SURE HOW TO MEASURE YOUR BLOOD PRESSURE After all display marks are disappeared, the last measured systolic / diastolic blood pressure values and pulse rate are displayed. Memory function works on for approximately 2 second or during depressed the "POWER" switch.
HOW TO MEASURE YOUR BLOOD PRESSURE 4.3 Press the exhaust button Press the exhaust button valve to completely release the air in the cuff. Exhaust button 4.4 Power off Press the "POWER" switch to turn off. 4.5 Subsequent measurement For another measurement, just pressurize the cuff by pumping bulb.
ABOUT “BLOOD PRESSURE” ACTION What is blood pressure? The heart is a pump that circulates blood throughout your body. Blood is pumped from the heart sure value at a constant pressure into arteries. This pressure is called the arterial blood pressure, which represents, in general, blood pressure. Blood pressure is indicated by several kinds of pressures such as: systolic pressure that occurs when the heart pumps blood;...
Page 11
SURE BEFORE ASKING FOR REPAIR/INSPECTION Be sure to check the following before sending your blood rent from pressure monitor for repair/inspection. Phenomenon Point to be checked How to repair ambient physician Display gives no Check whether batteries Replace all batteries with ure value indication even are dead.
Page 12
▲ sure: rent) ttery) eries) event of Downloaded from www.Manualslib.com manuals search engine...
Need help?
Do you have a question about the CH-311B and is the answer not in the manual?
Questions and answers