DIMENSIONS
(Unit: mm)
REMOTE CONTROLLER
Wireless type
Remote controller dimensions
BRC7F633F BRC4C64
Remote controller holder
Transmitting part
installation procedure
<Installation to wall surface>
Liquid crystal
remote controller
(Wireless)
Remote controller
holder
62
17.5
BRC7NU66
Transmitting part
Remote controller holder
installation procedure
<Installation to wall surface>
Remote controller
(Wireless)
Remote controller
holder
54
18.1
Wired type
Remote controller dimensions
BRC1C61
120
17
18
Cord
outlet
23
28
hole
46
BRC1E62
Upper case
Lower case
Operation
   
lamp
(Green)
Code outlet hole
120
19
28
5
15 oblong hole
X
23
48.5
5
X
7 oblong hole
46
BRC1NU61
44.5
Note)
25
The dimension of hole.
20
A
B
B
17
B
20
25
A
A
A
Hole type
A
41
38
111
24
B
41.5
27
CEILING MOUNTED CASSETTE TYPE <Round Flow>
• Receiver installation procedure
• Receiver detail
Receiver
Refrigerant
piping side
Decoration panel
Drain piping
side
CEILING SUSPENDED TYPE
Receiver installation procedure
Receiver detail
The Front
Receiver
Receiver detail
2-5
x
9 Slot
Service space for ceiling
installation
Note :
Do not install more than 3
receivers in the vicinity of one
another.
0.5
With 4 or more units, there is
49
70
18
35
always the possibility of
(Ceiling opening)
malfunction
Switch box
(field Supplied parts)
Remote controller installation procedure
A EXposed body, exposed cord
B Exposed body, embedded cord
C Exposed body, embedded code
17
Conduit
Staple
0~5
17
( Distance between
remote controller
17
CONTROL BOX
and control box )
Note) 1. Remote controller cord and
Specifications of cord
staple are not attached.
Type
Vinyl cord with sheath or cable
(Insulated thickness: 1 mm or more)
they are field supplied
Size
0.75~1.25 mm
2
parts.
Total length
500 m
* Countries requiring EMC: Shield wire (insulated thickness: 1 mm or more)
• Installation method
A Exposed cord
B Embedded cord
C Embedded cord
Staple
(use switch box)
Top left
19
Top center
outlet
outlet
Note)2
28
48.5
Through hole
Switch box for one switch
Switch box for two switch
Left outlet
( 8- 10)
19
Lower case portion
ex.) KJB111A
ex.) KJB211A
(optional accessory)
(optional accessory)
Lower case portion
Note)
1. Remote controller cord and staple are not attached. They are field
2.If the hole size is too large or the location
supplied parts.
is not proper, the hole may come out from
the remote controller.
Specifications of cord
Type
Vinyl cord with sheath or cable (insulated thickness: 1mm or more)
Size
0.75~1.25 mm
2
Total length
500 m
a
a (mm)
6
10
Installation service space for outdoor unit
For RNQ30-48MV1/Y1
1
When there is an obstruction on the inlet side
1) When the overhead space is open
1. For single unit installation
When there is an
obstruction only
on the inlet side
When there are obstructions
on both sides
2. For multiple units installation
(more than two units)
When there are
obstructions on
both sides
2)
When there is an obstruction
in the overhead space
1. For single unit installation
When there is an
Through hole
obstruction on the
(fl12~fl16)
inlet side
When there are obstructions
on the inlet side and
both sides
Condit
19
46
0~5
(Between remote
controller and
2. For multiple units installation (more than two units)
control box)
Switch box
[field supplied part]
When there are obstructions
on the inlet side and
both sides
Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.
2
When there is an obstruction on the outlet side
1) When the overhead space is open
1. For single unit installation
2. For multiple units installation
2) When there is an obstruction
in the overhead space
1. For single unit installation
2. For multiple units installation
An obstruction
in the overhead
space
3
When there are obstructions on both
the inlet and outlet sides
(When the obstruction on the outlet side is higher than the
unit itself)
1) When the overhead space is open
An obstruction
in the overhead
space
1. For single unit installation
2. For multiple units installation
An obstruction
in the overhead
space
(Unit: mm)
(more than two units)
An obstruction
in the overhead space
(more than two units)
An obstruction
in the overhead space
(There is no limit to the height of the obstruction on the
outlet side.)
L
H
(more than two units)
L
H
28