Connect Both Power Leads To A Fuse Panel; Verify The Connection; Establish Your Uplink Connections - Net to Net Technologies 4-Module IP DSLAM IPD4000E Installation Instructions Manual

4-module ip dslam: internet protocol digital subscriber line access multiplexer
Table of Contents

Advertisement

DC POWER
TERMINAL
Ring
Terminal
C
AUTION Be sure to attach THE POSITIVE LEAD TO THE POSITIVE TERMINAL and the NEGATIVE LEAD TO THE

1.5.3.3 Connect Both Power Leads to a Fuse Panel

The negative (-) lead connects to a "Batt" (Battery) terminal and the positive
(+) lead connects to a "Return" terminal on your DC power supply.
C
AUTION The power source(s) connected to the IPD4000E must be equipped with a disconnect device such

1.5.4 Verify the Connection

Turn your power source(s) on. The PWR (power) LED on both the interface module
and management module faceplates will illuminate solid green to indicate the
modules are receiving power.
MANAGEMENT

1.6 Establish Your Uplink Connections

N
OTE No configuration is necessary for Uplink Interface Modules (UIMs) or Media Interface Modules (MIMs), as installed on
the management module(s) in your IPD4000E, to operate at default settings. However, if you wish to run your uplink
connections at settings other than the UIM or MIM defaults, Net to Net recommends configuring the UIM or MIM
prior to connection.
For further connection and configuration information, refer to the installation
instructions of your particular UIM or MIM model at
http://www.nettonet.com/support/docs
IPD4000E Installation Instructions 220-0000097 rev01
  
  
   
NEGATIVE TERMINAL as indicated on your IPD4000E terminal block labels.
as an On/Off switch. Otherwise, an appropriately rated circuit breaker must be installed on each
power circuit to be used. In the case of an emergency, hazardous voltages will not be removed
from the IPD4000E until all power sources have been either turned off or disconnected from the
chassis.
MODULE
 
Power LED
                    
Negative (-)
Terminal
                                
NEGATIVE
POWER LEAD
INTERFACE
MODULE
Power LED
.
Page 10 of 17