Panel Location; Power And Wire Length - Interlogix Concord 4 RF Installation Manual

Table of Contents

Advertisement

Phone line
Allow s panel to communicate w ith central
connection
monitoring station and/or pagers.
Note:
The total current sourced from all terminals cannot
exceed 1 amp.

Panel location

Before permanently mounting the panel, use the
following guidelines to choose a mounting location.
To help reduce wire run lengths and labor, centrally locate
the panel with relation to detection devices whenever
possible.
Locate the panel where the temperature will not exceed
120ºF (49ºC) or fall below 32ºF (0ºC).
To prevent wire runs from picking up electrical noise,
avoid running wires parallel with electrical wiring or fixtures
such as fluorescent lighting.
Mount the panel at a comfortable working height.
Leave at least 24 inches in front of the panel to open the
cabinet door and access the panel.
Leave space to the left and right of the panel for wiring,
phone jack, and mounting optional modules.
Leave at least 9 inches above the panel cabinet for
antennas.

Power and wire length

The panel can supply up to 1 amp (1,000 mA) in full load
alarm condition for system devices connected to panel
terminals 4 (+12V), 7 and 8 (speaker terminals), 9
(OUT1), 11 (+12V), 24 (2W SMK ZONE 8), and
SnapCard terminals.
For 24-hour backup, the total standby current draw for all
devices connected to panel terminals 4 (+12V), 9
(OUT1), 11 (+12V), 24 (if configured for two-wire smoke
loop), and SnapCard terminals is limited to 90 mA
(during normal standby condition) using a 4.5 or 5.0 Ah
battery, or 190 mA (during normal standby condition)
using a 7.0 Ah battery.
The total system wire length allowed can vary depending
on devices powered by the panel, the wire length
between devices and the pane, and the combined wire
length of all devices.
Table 3 below describes the maximum wire length
allowed between compatible devices and the panel, and
the minimum and maximum current draw of each device.
2
Table 3: Wire length requirements
Device
SuperBus 2000 2x16 LCD
alphanumeric touchpad
SuperBus 2000 ATP 1000
alphanumeric touchpad
SuperBus 2000 ATP 2100
alphanumeric touchpad
SuperBus 2000 ATP 2600
alphanumeric touchpad
SuperBus 2000 GTS 50
SuperBus 2000 fixed display
touchpad
SuperBus 2000 FTP 1000
fixed display touchpad
SuperBus 2000 RF
transceiver
SuperBus 2000 RF receiver
1
SuperBus 2000 phone
interface/voice module
SuperBus 2000 voice-only
module
SuperBus 2000 2 amp
pow er supply
4 input/2 output SnapCard
8Z hardw ired zone
expander SnapCard
4 output SnapCard
SuperBus 2000 8Z input
module
SuperBus 2000 4-relay
output module
SuperBus 2000 energy
saver module
SuperBus 2000 cellular
backup module
SuperBus 2000 automation
module
SuperBus 2000 w ireless
gatew ay-ready kit
Interrogator 200
Max. w ire
Standby
Alarm m A
length to
m A draw
draw
panel
22 ga.: 300 ft.
15 mA
90 mA
18 ga.: 750 ft.
22 ga.: 300 ft.
12 mA
110 mA
18 ga.: 750 ft.
22 ga.: 300 ft.
30 mA
165 mA
18 ga.: 750 ft.
22 ga.: 300 ft.
30 mA
165 mA
18 ga.: 750 ft.
22 ga.: 100 ft.
270 mA
300 mA
18 ga.: 250 ft.
22 ga.: 300 ft.
11 mA
65 mA
18 ga.: 700 ft.
22 ga.: 300 ft.
12 mA
75 mA
18 ga.: 700 ft.
22 ga.: 1,000 ft.
45 mA
55 mA
18 ga.: 2,500 ft.
22 ga.: 1,100 ft.
35 mA
35 mA
18 ga.: 2,800 ft.
22 ga.: 40 ft.
25 mA
600 mA
18 ga.: 120 ft.
22 ga.: 40 ft.
20 mA
300 mA
18 ga.: 120 ft.
(jumper)
600 mA (no
jumper)
N/A
No load
No load
N/A
20 mA
185 mA
N/A
38 mA
230 mA
N/A
1 mA
130 mA
22 ga.: 1,800 ft.
18 mA
35 mA
18 ga.: 4,000 ft.
22 ga.: 350 ft.
12 mA
180 mA
18 ga.: 900 ft.
22 ga.: 1,600 ft.
20 mA
20 mA
18 ga.: 4,000 ft.
Standard
90 mA
1600 mA
pow er 22 ga.:
15 ft. 18 ga.:
40 ft. High
90 mA
1900 mA
pow er
22
ga.: 10 ft.
18
ga.: 30 ft.
22 ga.: 1,500 ft.
30 mA
35 mA
18 ga.: 4,000 ft.
22 ga.: 40 ft.
65 mA
1600 mA
18 ga.: 90 ft.
22 ga.: 3,200 ft.
10 mA
10 mA
18 ga.: 4,500 ft.
Concord 4 Installation Guide
1
1
1