Owner's manual Inddor units MVD DC CONTENTS PAGE Do not insert fingers, rods or other objects into the air inlet or outlet. IMPORTANT SAFETY INFORMATION............1 When the fan is rotating at high speed, it will cause injury. PARTS NAMES..................3 Never use a flammable spray such as hair spray, lacquer AIR CONDITIONER OPERATIONS AND PERFORMANCE......6 or paint near the unit.
Owner's manual Inddor units MVD DC In order to avoid electric shock or fire, make sure that an NOTE earth leak detector is installed. All the pictures in this manual are for explanation purpose only. Be sure the air conditioner is grounded. They may be slightly different from the air conditioner you In order to avoid electric shock, make sure that the unit is purchased(depend on model).
Page 4
Owner's manual Inddor units MVD DC ■ ■ Small one-way cassette type High static pressure duct type Grounding Screw (In the control box) Heat Exchanger Air Out, Air Out Louver (Exchange cool air into warm air) Air Outlet (Adjust the air-Aout direction) (Outlet room air) Air Intake (Intake room air here)
Page 5
Owner's manual Inddor units MVD DC ■ Console type Indoor unit Installation part Air flow louver Low-pressure pipe Display panel (at air outlet) Connecting pipe Outlet pipe Air inlet Hi-pressure pipe Inlet pipe (with air filter in it) Throttle part Electric control box Air flow louver Drain pipe...
Owner's manual Inddor units MVD DC ● Concealed Floor Standing (Version III) NOTE Vertical unit for building-in,with air intake from below and air delivery at the top,for installation on a wall. If air conditioner is used outside the above conditions, it may cause the unit to function abnormally.
Owner's manual Inddor units MVD DC ● When using the panel with auto.louver, press SWING button , the To maintain the comfortable temperature. auto, louver will swing automatically and the best cooling (heating) Adjust the air-out direction with using the air-out louver. effects will be achieved.
Page 8
Owner's manual Inddor units MVD DC ■ ● Duct-ceiling type When heating Adjust the louver down(vertically). The following is how to adjust the air flow direction when the air outlet parts (sold separately) is used with the indoor unit. ● When cooling To effectively heat the bottom of the room please set the louver downwards.
Page 9
Owner's manual Inddor units MVD DC ● Manual swing CAUTION Press Air Direction button,the louver can be fixed at a desired angle.The louber swing (upward or downward ) to a certain angle for each press. Water drop may be caused on the surface of the unit or horizantal louver when cooling while the air-out direction is vertically down.
Page 10
Owner's manual Inddor units MVD DC ■ Two-way cassette type CAUTION Before opening the front panel,be sure to stop the operation and turn the breaker OFF. ● Auto-swing Do not touch the metal parts on the inside of the indoor Press SWING button, the louver will swing up and down unit, as it may result in injury.
Owner's manual Inddor units MVD DC 5. Maintenance CAUTION Before you clean the air conditioner, be sure the power supply is off. Check if the wiring is not broken off or disconnected. Use a dry cloth to wipe the indoor unit and remote Fig.5-2 controller.
Page 12
Owner's manual Inddor units MVD DC ■ Two-way cassette type Air Outlet Selection Switch ■ Take off the inhalation grating from the panel. 1) Upright row (non-directional) one side of the inhalation grating, and putdown the other side, and then slide follow the arrow’s direction refers to Fig.5-9 2) Loosen the hanger of the putdown side refers to Fig.5-10 3) Open the inhalation grating (about 45°), and remove the...
Page 13
Owner's manual Inddor units MVD DC ● For wall mounted Type 4. Re-install the air filter. 5. Install and close the air-in grill in the reverse orders of step 1 and 2 and connect the control box cables to the corre sponding terminators of the main body.
Owner's manual Inddor units MVD DC 6. Following symptoms are not Symptom 4.2: Indoor unit, outdoor unit air conditioner troubles A continuous low hissing sound is heard when the system is in operation. Symptom 1: The system does not operate This is the sound of refrigerant gas flowing through both indoor and outdoor units.
Owner's manual Inddor units MVD DC 7. Troubleshooting 7.1. Troubles and causes of air conditioner If one of the following malfunctions occur, stop operation, shut off the power, and contact with your dealer. Remote controller receives malfunction or the button does not work well. A safety device such as a fuse, a breaker frequently actuates.
Page 16
Owner's manual Inddor units MVD DC 7.2. Troubles and causes of remote controller Before asking for serving or repairing, check the following points.(See in Table 7-2) Table 7-2 Symptoms Causes Solution Check whether the MODE When the automatic mode is indicated on the display is selected, the air conditioner will "AUTO"...
Owner's manual Inddor units MVD DC 8. Remote controller Please remove the nearby electronic device for they may affect the performance of remote controller. If necessary, contact the local Midea Safety precautions service centre or technical support centre. The following contents are stated on the product and the operation Do not put the used or different batteries into the remote controller, manual, including usage, precautions against personal harm and otherwise remote controller will fail to send signal.
Page 18
Owner's manual Inddor units MVD DC ¢ Ù MODE: Once pressing, running mode will be selected in ECO: Activate or turn off economic operation mode. It is the following sequence: suggested to turn on this function when sleeping. (Only ¡ ú ¡...
Page 19
Owner's manual Inddor units MVD DC 8.1.4. Operation instructions Set TIME ON and TIME OFF simultaneously 1. Set TIME ON according to procedures 1 and 2 specified in Install and replace batteries TIME ON operation Install 2 pieces of 7# alkaline batteries. 2.
Owner's manual Inddor units MVD DC ④ TIMER: 8.2. Wireless remote controller RM02A Under the OFF state, press this button, TIMER ON are ligtened. continue to press TIMER button, the time will increase by 0.5 ● The outline figure on cover is for reference only, hour.
Page 21
Owner's manual Inddor units MVD DC 8.2.3. Names of indicators and their 8.2.4.2. Auto operation (Normal) functions AUTO operation Timer ON/OFF ④ TEMP Transmitting ON/OFF AUTO MODE Lock ① ⑤ display TIMER ON TIMER OFF FAN SPEED FAN SPEED ON/OFF ②...
Owner's manual Inddor units MVD DC Follow me function Auto heat recycling mode function instruction Function instruction Function DRY E •A•H FOLLOW ME ΔT:Temperature difference, means the different temperature This air conditioner has follow me function, Fig.5-4 between the indoor temperature (Tf) detected by the remote when this function is operated, the remote controller and the remote controller setting temperature (Ts).
Owner's manual Inddor units MVD DC Setting timing OFF 8.3. Wired remote controller KJR-29B TIMER OFF TIMER OFF TIMER TIMER OFF TIMER ● This manual gives detailed description of the precautions COOL COOL COOL that should be brought to your attention during operation. FAN SPEED FAN SPEED ●...
Owner's manual Inddor units MVD DC After finish adjusting the timer on setting, press the CAUTION button or wait for 5 seconds to confirm and exit the timer on setting. The wired remote controller will not receive the swing Under the timer on setting status, press the timer/clock controlling instruction.
Owner's manual Inddor units MVD DC ● Air filter cleanning reminding function The wired remote controller records the total running time of the indoor unit, when the accumulated running time reaches the pre-setted value, the air filter of the indoor unit need to be cleaned. Long press for 3 seconds, and reset the reminding icon and the wired remote controller will...