Vertex VX-410 series Service Manual page 18

Hide thumbs Also See for VX-410 series:
Table of Contents

Advertisement

Alignment
CTCSS Deviation
Ì Set the transceiver to CH 2 (band center).
Ì To adjustment, click the left mouse button on the
"CTCSS Modulation" box, then press the [
key to open the pop-up window.
Ì Use the [ ] or [ ] arrow keys so that the deviation
meter reading is ±0.8 kHz (±0.1 kHz) (for 25 kHz steps)
or ±0.5 kHz (±0.1 kHz) (for 12.5 kHz steps) deviation.
Ì Press the "OK" box to lock in the new data.
MAX Ref Deviation
Ì Set the transceiver to CH 2 (band center).
Ì To adjustment, click the left mouse button on the "MAX
Ref Deviation" box, then press the [
open the pop-up window.
Ì Use the [ ] or [ ] arrow keys so that the deviation
meter reading is ±0.6 kHz (±0.2 kHz) (for 25 kHz steps)
or ±0.4 kHz (±0.1 kHz) (for 12.5 kHz steps) deviation.
Ì Set the transceiver to CH 2 (band center), then key the
transmitter, and confirm that the deviation is ±0.6 kHz
~ ±0.9 kHz (for 25 kHz steps) or ±0.35 kHz ~ ±0.6
kHz (for 12.5 kHz steps).
Ì Press the "OK" box to lock in the new data.
STD Deviation
Ì Set the transceiver to CH 2 (band center).
Ì Inject a 1 kHz tone at –37 dBm to the
Ì To adjustment, click the left mouse button on the "MIC
Sensitivity" box, then press the [
the pop-up window.
Ì Use the [ ] or [ ] arrow keys so that the deviation
meter reading is ±3.0 kHz (±0.1 kHz) (for 25 kHz steps)
or ±1.5 kHz (±0.1 kHz) (for 12.5 kHz steps) deviation.
Ì Press the "OK" box to lock in the new data.
18
DTMF Deviation
Ì Set the transceiver to CH 2 (band center).
Ì To adjustment, click the left mouse button on the
]
"DTMF Deviation" box, then press the [
to open the pop-up window.
Ì Use the [ ] or [ ] arrow keys so that the deviation
meter reading is ±3.0 kHz (±0.1 kHz) (for 25 kHz steps)
or ±1.5 kHz (±0.1 kHz) (for 12.5 kHz steps) deviation.
Ì Press the "OK" box to lock in the new data.
DCS Deviation
Ì Set the transceiver to CH 2 (band center).
Ì To adjustment, click the left mouse button on the "DCS
] key to
Modulation" box, then press the [
the pop-up window.
Ì Use the [ ] or [ ] arrow keys so that the deviation
meter reading is ±0.7 kHz (±0.1 kHz) (for 25 kHz steps)
or ±0.45 kHz (±0.1 kHz) (for 12.5 kHz steps) devia-
tion.
Ì Press the "OK" box to lock in the new data.
Sensitivity
Ì Set the transceiver to CH 3 (high band edge).
Ì Tune the RF signal generator to the same frequency as
the transceiver's, then set the generator output level to
40 dBµ with ±3.0 kHz deviation @ 1 kHz tone modu-
jack.
lation.
Ì To adjustment, click the left mouse button on the "RX
Sensitivity" box, then press the [
the pop-up window.
Ì Use the [ ] or [ ] arrow keys to tune for best sensi-
tivity; ultimately, the radio should be aligned so that
the RF signal generator output level is –6 dBµ EMF
(0.25 µV) or less for 12 dB SINAD.
Ì Press the "OK" box to lock in the new data.
] key to open
This completes the internal alignment routine. To save all
settings and exit, press the "OK" box.
] key
] key to open
] key to open