4-1-17 FI SYSTEM DIAGNOSIS

MALFUNCTION CODE AND DEFECTIVE CONDITION

MALFUNCTION
DETECTED ITEM
CODE
NO FAULT
C00
C12
Pick-up coil
Throttle position sensor
C14
(TPS)
Water temperature
C15
sensor (WTS)
Intake air pressure
C17 / C18
sensor (IAPS),
NO.1 / NO.2
Intake air temperature
C21
sensor (IATS)
C22
Oxygen sensor (O
C23
Tip over sensor (TOS)
DETECTED FAILURE CONDITION
The signal does not reach ECU for more than 2 sec. after
receiving the IAP signal.
Pick-up coil wiring and mechanical parts.
(Pick-up coil, lead wire coupler connection)
The sensor should produce following voltage.
0.2 V � sensor voltage � 4.8 V
Without the above range for 5 sec. and more, C14 is indicated.
Throttle position sensor, lead wire / coupler connection.
The sensor voltage should be the following.
0.2 V � sensor voltage � 4.6 V
Without the above range for 5 sec. and more, C15 is indicated.
Water temperature sensor, lead wire / coupler connection.
The sensor should produce following voltage.
0.2 V � sensor voltage � 4.8 V
Without the above range for 5 sec. and more, C17 or C18 is
indicated.
Intake air pressure sensor, lead wire / coupler connection.
The sensor voltage should be the following.
0.2 V � sensor voltage � 4.6 V
Without the above range for 5 sec. and more, C21 is indicated.
Intake air temperature sensor, lead wire / coupler connection.
The oxygen sensor signal is input in ECU since then 180 sec.
after the engine run.
When this is the case, ECU not receive the signal, C22 is
S)
2
indicated.
Oxygen sensor, lead wire / coupler connection.
The sensor voltage should be the following for more than 5 sec.
after ignition switch turns "ON" position.
0.2 V � sensor voltage � 4.6 V
Without the above value for 5 sec. and more, C23 is indicated.
Tip over sensor, lead wire / coupler connection.