JVC KD-AVX1 Service Manual page 37

Table of Contents

Advertisement

4.6.9 Monitor adjustment
When adjusting, switch on the main unit and insert a test disc (VT-501). And play the test disc and pause it.
(Exit for VCO FREE-RUN adjustment)
R/W CHROMA 1
1. Set the service mode 4.
2. Exchanging it operate a menu of a service mode with the [UP] button and [DOWN] button.
3. Change data with the [B.SKIP]/[F.SKIP] buttons.
4. Write data with a [OK] button.
When performing the VCO FREE-RUN N adjustment, set the NTSC mode (Service mode 3
DVD NTSC/PAL) and turn the input into the no input. Connect the frequency counter to the point (TP661 or
TP681-GND) on the panel board and set the frequency into 15.62
When performing the VCO FREE-RUN P adjustment, set the PAL mode (Service mode 3
DVD NTSC/PAL) and turn the input into the no input. Connect the frequency counter to the point (TP661 or
TP681-GND) on the panel board and set the frequency into 15.73
Indication
Minimum value
COM AMPLITUDE
BRIGHT GAIN
COLOR GAIN N
COLOR GAIN P
TINT N
TINT P
BLACK LIMITER
BRIGHT
APERTURE
R SUB BRIGHT
B SUB BRIGHT
W PEAK LIMITER
GAMMA1
GAMMA2
CONTRAST
R SUB CONTRAST
B SUB CONTRAST
VCO FREE RUN N
VCO FREE RUN P
PLL STOP POS
V POSITION
H POSITION
PWM FREQUENCY
BRST CLN PLS POS
PWM DUTY
COM DC
DC OUTPUT
R/W CHROMA 2
1. Set the service mode 4.
2. Exchanging it operate a menu of a service mode with the [UP] button and [DOWN] button.
3. Change data with the [B.SKIP]/[F.SKIP] buttons.
4. Write data with a [OK] button.
Indication
Minimum value
H POSITION
V POSITION
HDO POSITION
BRIGHT
R BRIGHT
B BRIGHT
COMLEVEL M
COMLEVEL E
COMDC M
COMDC E
VCO N
VCO P
Maximum value
Initial value
0x00
0xFF
0x80
0x00
0xFF
0x80
0x00
0xFF
0x80
0x00
0xFF
0x80
0x00
0xFF
0x80
0x00
0xFF
0x80
0x00
0x7F
0x40
0x00
0xFF
0x80
0x00
0x7F
0x40
0xFF
0x00
0x80
0x00
0xFF
0x80
0x00
0x7F
0x40
0x00
0xFF
0x80
0x00
0xFF
0x80
0x00
0xFF
0x80
0x00
0xFF
0x80
0x00
0xFF
0x80
0x00
0xFF
0x80
0x00
0xFF
0x80
0x00
0x0F
0x00
0x00
0x07
0x00
0x00
0x1F
0x00
0x00
0x0F
0x08
0x00
0x07
0x00
0x00
0xFF
0x80
0x00
0xFF
0x80
0x00
0xFF
0x80
Maximum value
Initial value
0x00
0x1F
0x10
0x00
0x0F
0x08
0x00
0x1F
0x00
0x00
0x7F
0x40
0x00
0x7F
0x40
0x00
0x7F
0x40
0x00
0x1F
0x10
0x00
0x1F
0x10
0x00
0x3F
0x29
0x00
0x3F
0x32
0x00
0xFF
0x80
0x00
0xFF
0x80
0.01 (kHz).
0.01 (kHz).
Production jig initial value Reference register value
0x80
0x80
0x5F
0x62
0x82
0x80
0x5E
0xA3
0x40
0x88
0x88
0x7F
0x80
0xFF
0x64
0x74
0x78
0x8C
0x89
0x08
0x02
0x1F
0x08
0x03
0xFF
0x80
0x65
Production jig initial value Reference register value
0x12
0x08
0x02
0x4D
0x3E
0x40
0x09
0x10
0x33
0x32
0x70
0x76
Service mode
Service mode
0x80
Fix
0x80
Fix
0x60
Adjust
0x62
Adjust
0x6D
Adjust
0x80
Adjust
0x5E
Fix
0xA3
Adjust
0x40
Fix
0x88
Adjust
0x89
Adjust
0x7F
Fix
0x80
Fix
0xFF
Fix
0x65
Adjust
0x71
Adjust
0x74
Adjust
0x8F
Adjust
15.62 kHz
0x8B
Adjust
15.73 kHz
0x08
Fix
0x02
Fix
0x1F
Fix
0x08
Fix
0x03
Fix
0xFF
Fix
0x80
Fix
0x43
Adjust
0x13
Adjust
0x08
Adjust
0x02
Fix
0x4E
Adjust
0x3E
Adjust
0x41
Adjust
0x08
Adjust
0x10
Fix
0x31
Adjust
0x32
Fix
0x61
Adjust
0x69
Adjust
(No.MA165)1-37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents