Alternate Venting - Pacific energy The Oxford Installation And Operating Instructions Manual

Series a direct vent heater
Table of Contents

Advertisement

SIMPSON DURA-VENT - DIRECT VENT GS SYSTEM
The Oxford Direct Vent Heater is tested and certified for use with
SIMPSON DURA-VENT DIRECT VENT GS pipe. Kits for venting
either through the wall or vertically through the roof are available from
Simpson Dura-Vent or your nearest Pacific Energy Authorized Dealer.
Before installing the Dura-Vent system, the installer should read these
instructions to ensure proper installation requirements are main-
tained. Follow vent pipe manufacturer's instructions for assembly and
installation.
Fig. # 9a
f i r e - p a r t s . c o m

ALTERNATE VENTING

OXFORD DURA-VENT
PIPE ADAPTOR
PEVT.OXADPT
CAUTION: UNDER NO CONDITION SHOULD COMBUSTIBLE
MATERIAL BE CLOSER THAN 1-1/4 INCHES FROM ANY VERTI-
CAL OR HORIZONTAL VENT SECTIONS OF THE SIMPSON DURA-
VENT DIRECT VENT GS SYSTEM.
To connect the Dura-Vent GS venting system to the Oxford Direct
Vent Heater flue outlet, an Oxford Pipe Adaptor (PEVT.OXADPT) is
required.
WALL TERMINATION
Minimum Installation
VERTICAL RISE
MINIMUM 6 INCHES