Daewoo KUD-WD135 SERIES Service Manual page 52

Table of Contents

Advertisement

rum Wa
#$!Water Level Sensor
1) Spec. of Water Level Sensor
O/F: Forced drainage is
necessary as water
level is high. When
this level is reached,
water supply must be
stopped and drainage
must be forcefully
administered.
Model
Code
Classification
3614825220
Frequency
WD1132
DN-DD03,
Water level
DL-DW03
(mm)
2) Breakdown Analysis
Symptoms
Detailed Symptoms
Continuous
Water valve normal
water
supply
"E9"
Occurrence in water level
sensor
30kHz or higher
RESET :
1. Spin-drying begins
30sec after drainage
level reset is reached.
2. Heater operation level
O/F
Medium High Medium
22.603
23.103
23.203
260515
225515
22057
Cause
Defect in pressure sensor
hose
Blocking of pressure sensor
hose
Connector loosened
Wiring short
51
Low: Small load of laundry, therefore considered to be
water level of 'low'
Medium: Large load of laundry
Medium High: Water level for rinsing
Safety: Door open possible
Door opened only when water level is below
safety level
Low
Safety
24.003
24.403
170515
140515
Diagnosis
Check for holes.
Replace hose.
Visual checking
Remove foreign substances.
Visually check connector
Administer re-insertion.
connection status.
Wiring short ->
conduction test
Reset
Initial(Defect) Inlet Angle
24.703
25.803
904
120520
0
PCB Error
Solution
Mode
"E2"
"E2"
"E9"
"E9"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dwd-wd135 seriesDwd-wd135*02

Table of Contents