Configure Login Credentials; Configuring Switch Ports; Save Configuration And Reload - Dell Networking S4810 Configuration Manual

Hide thumbs Also See for Networking S4810:
Table of Contents

Advertisement

5.8

Configure login credentials

FTOS(conf)#username admin privilege 15 password 0 yourpassword
FTOS(conf)#enable password level 15 0 yourpassword
5.9

Configuring switch ports

FTOS(conf)#interface range tengigabitethernet 0/0 – 47
FTOS(conf-if-range-te-0/0-47)#mtu 12000
FTOS(conf-if-range-te-0/0-47)#switchport
FTOS(conf-if-range-te-0/0-47)#spanning-tree rstp edge-port
FTOS(conf-if-range-te-0/0-47)#flowcontrol rx on tx off
FTOS(conf-if-range-te-0/0-47)#no shutdown
FTOS(conf-if-range-te-0/0-47)#exit
FTOS(conf)#interface range tengigabitethernet 1/0 – 47
FTOS(conf-if-range-te-1/0-47)#mtu 12000
FTOS(conf-if-range-te-1/0-47)#switchport
FTOS(conf-if-range-te-1/0-47)#spanning-tree rstp edge-port
FTOS(conf-if-range-te-1/0-47)#flowcontrol rx on tx off
FTOS(conf-if-range-te-1/0-47)#no shut
FTOS(conf-if-range-te-1/0-47)#exit
FTOS(conf)#protocol spanning-tree rstp
FTOS(conf-rstp)#no disable
FTOS(conf-rstp)#exit
FTOS(conf)#exit
5.10

Save configuration and reload

FTOS#copy running-config startup-config
Reload the stack to allow settings to take effect:
FTOS#reload
Note: The preceding procedure places all switch ports in the default VLAN. If you prefer to place ports in
a non-default VLAN, refer to the documentation for your switch.
16