RS-232C
$ Query control commands
Data transmitted by PC
[STX] QPB:m [ETX]
Parameter
m = D: Date information
T: Time information
C: Camera connection information
R: Recording time mode information
A: Alarm number information
O: Monitor screen display information
[STX] LPBm:r:data [ETX]
Parameter
m = D: Date information
r = O: READ OK
N: READ NG
data = yyyymmdd
yyyy = 2000—2099: Gregorian
calendar
mm= 01—12: Month
dd = 01—31: Day
m = T: Time information
r = O: READ OK
N: READ NG
data = hhmmss
hh = 00—23: Hours
mm = 00—59: Minutes
ss = 00—59: Seconds
m = C: Camera connection information
r = O: READ OK
N: READ NG
data = c
c
c
c
13-16
9-12
5-8
1-4
c
= 1—F:
13-16
Connection information for
camera No.13—16
c
= 1—F:
9-12
Connection information for
camera No.9—12
c
=
1—F:
5-8
Connection information for
camera No.5—8
c
=
1—F:
1-4
Connection information for
camera No.1—4
<Note>
For details on C¢, refer to the camera
connection information table.
Queries the playback tape information.
Data returned from unit in response
m = R: Recording time mode information
r = O: READ OK
N: READ NG
data = t
t = 0: 3-hour recording
1: 9-hour recording
2: 12-hour recording
3: 18-hour recording
4: 24-hour recording
5: 48-hour recording
6: 72-hour recording
7: 96-hour recording
8: 120-hour recording
9: 180-hour recording
A: 240-hour recording
B: 360-hour recording
C: 480-hour recording
D: 960-hour recording
m = A: Alarm number information
r = O: READ OK
N: READ NG
data = nn
nn = 00—99: Alarm number
FF: No alarm data
95
Description of command
m = O: Monitor screen display information
r = O: READ OK
N: READ NG
data = xx:yy:d
d
1
2
xx = 00—22:
Position of head character (in
horizontal direction)
Position from left when monitor screen
has been divided horizontally into 22
segments.
yy = 00—14:
Position of head character (in vertical
direction)
Position from top when monitor screen
has been divided vertically into 14
segments.
d
d
= 00—FF:
1
2
Monitor screen display ON/OFF
<Note>
For details on d1d2, refer to the monitor
screen display information table.

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Ag-dtl1p

Table of Contents