RS-232C
$ Query control commands
Data transmitted by PC
[STX] QHJ [ETX]
[STX] QHL [ETX]
[STX] QHR:H [ETX]
[STX] QHR:H [ETX]
[STX] QHT [ETX]
[STX] QIC [ETX]
[STX] QID [ETX]
[STX] QIP:n [ETX]
Parameter
n = 1—8: Program registration
number (PGM1—PGM8)
Data returned from unit in response
[STX] HEm [ETX]
Parameter
m = E: EJECT
A: REWIND 5 EJECT
[STX] HRLm [ETX]
Parameter
m = F: Recording enabled
N: Recording disabled
[STX] HTRdata [ETX]
Parameter
data = hhmmss
hh = 00—23:
Hours
mm = 00—59:
Minutes
ss = 00 (fixed): Seconds
[STX] HTRdata [ETX]
Parameter
data = hhmmss
hh = 00—23:
Hours
mm = 00—59:
Minutes
ss = 00 (fixed): Seconds
[STX] HREm [ETX]
Parameter
m = B: BUZZER
E: EJECT
P: REPEAT
R: REWIND
S: STOP
[STX] 1 [ETX]
[STX] data [ETX]
Parameter
data = AG-DTL1P
[STX] LIPn:data1:data2:t [ETX]
Parameter
n = 1—8: Program registration number
(PGM1—PGM8)
data1 = hhmm (start time)
data2 = hhmm (end time)
hh = 00—23: Hours (24-hour system)
mm = 00—59: Minutes
t = 0—6: Recording type (RT0—RT6)
88
Description of command
Queries the setting for the operation to be performed when
the EJECT button is pressed.
Queries the lock mode for operations while recording is
underway.
Queries the remaining tape amount.
When the amount is undetermined or the tape has been
ejected, data = FFFFFF is returned.
<Note>
This command is valid when a 120-minute tape is used and
the 3-hour recording mode has been set.
Queries the remaining tape amount.
When the amount is undetermined or the tape has been
ejected, data = FFFFFF is returned.
<Note>
This command is valid when a 120-minute tape is used and
the 3-hour recording mode has been set.
Queries the unit's operation mode that is to be established
when the tape has reached its end position during
recording.
Queries the product area identification code.
The unit returns "1" for a tape component.
Queries the ID code of the unit.
Queries the program which combines three items—the
recording start time, recording end time and the recording
type—for recording using the unit's internal timer.