4.6 DIL switch functions

DIL-switch
1
Adjusts in combination with DIL 7 and 8 the functionality of the release
locking function
DIL 7
OFF
OFF
ON
ON
The release locking function can be reset by pressing the Lösen button
shortly (shorter than the selected locking time).
2
ON: fixed accelerator mode
OFF: linear accelerator mode
3
ON: Automatic alarm function enabled
OFF: Automatic alarm function disabled
4
ON: Pressing the Ziehen button automatically activates the pull- and
OFF: Pressing the Ziehen button only activates the pull-function
5
ON:
OFF: R3 is activated by pressing the Ziehen button (Movement-mode).
6
ON: Pressing the K.Lösen button activates the release function only as
OFF: Pressing the K.Lösen button pulses the release function in adjustable
7 - 8
See settings of DIL 1 for details
DIL 8
OFF
Function doesn´t lock
ON
Function is locked after
1,0 sec for 5 Minutes
OFF
Function is locked after
2,0 sec for 5 Minutes
ON
Function is locked after
3,0 sec for 5 Minutes
If you press the Gas+ button on the hand-held transmitter for at least
2 sec. the Gas+ function is latched. This mode is selected if you use a
solenoid or air cylinder to set a fixed accelerator position. The function
can be reset by pressing the Gas+ button shorter than 2 seconds.
In this mode you can continuously adjust the engine speed with an
actuator. The adjustment is done by the Gas+ and Gas- buttons.
Functionality described in section 4.1.4.
release-function
R3 is activated if you either press the Ziehen or Lösen button
(Follow-up mode). You select this mode for example if you have to
drive an external hydraulic pump whenever the hydraulic system
needs pressure.
You select this mode for example to drive a warning light whenever
the winch is pulling.
long as you press the button.
intervals
Functionality
DIL 1 = ON
DIL 1 = OFF
Function is locked after
0,5 sec permanently
Function is locked after
1,0 sec permanently
Function is locked after
2,0 sec permanently
Function is locked after
3,0 sec permanently