INFORMATION CODES

Code
Symbol
KEY SHORT ERROR
This error occurs when a button is
pressed and held for over 60 seconds.
MICROWAVE ABNORMAL TEMP
SENSING ERROR
It occurs when the temperature of cavity
inside is over 210 °C in the Microwave
Mode.
TEMP SENSOR TARGET TEMP
ERROR
It occurs when the preheating is not
completed and the temperature of cavity
inside is under 120 °C for 30 minutes.
TEMP SENSOR OPEN ERROR
It occurs due to a defective sensor,
misplaced wires, a defective PCB.
TEMP SENSOR SHORT ERROR
It occurs due to a defective sensor,
misplaced wires, a defective PCB.
ABNORMAL TEMP SENSING ERROR
It occurs when the temperature of cavity
inside is over 250 °C for 10 minutes.
COMMUNICATION ERROR
72_ troubleshooting and information code
NQ50C7535DS_SA_DG68-00470D_EN.indb 72
Problem
Solution
Press STOP/CANCEL
to stop the oven. After
cooling, please restart the
oven.
OVEN has still same
problem after above
action, then contact an
authorized SAMSUNG
Customer Service.
If any of these errors
occur, please contact
SAMSUNG Customer
Service.