TROUBLE SHOOTING
Check the following before contacting technical support:
Problem
The unit does not
work.
The device does not
dehumidify.
The dehumidifier
works, but reduces the
relative humidity insuf-
ficiently.
Indicator light 1 will
blink 5 times a second.

CONDITIONS OF WARRANTY

There is a two-year warranty on your dehumidifier from the date of purchase. All material
or manufacturing defects will be repaired free of charge.
The following applies:
All claims for compensation, including consequential damage, will not be entertained.
Any repairs or replacement of components during the warranty period will not result
in an extension of the warranty period.
The warranty will expire if any alterations have been made, not genuine components
have been fitted or if the dehumidifier has been repaired by a third party.
Components subject to normal wear and tear, such as the air filter, are not covered by
the warranty.
The warranty is only valid on presentation of the original, unaltered, and date-
stamped purchase receipt.
Cause
The powercord is not con-
nected.
The required humidity setting
is too high.
The water container is full.
The water container has not
been replaced correctly.
The air filter is clogged.
The temperature or relative
humidity in the room where
the device is operating is too
low.
The room is too large.
There are too many sources of
humidity.
There is too much ventilation.
Temperature or air humidity
sensor malfunction
Solution
Insert the plug into the wall
outlet.
Turn the required humidity to
a lower desired setting.
Remove the water from the
container.
Place the water container in
the correct position.
Clean the air filter.
It is normal that the device
does not dehumidify in these
conditions.
We recommend using a
dehumidifier with a greater
capacity.
We recommend using a
dehumidifier with a greater
capacity.
Reduce ventilation (e.g. close
curtains and shut doors).
Remove the plug from the
socket and wait for 10 sec-
onds. Plug in and start the
unit. If light 1 continues to
blink, then contact a Qlima
dealer.