Identifying Physical Irf Ports On The Member Switches; Planning The Cabling Scheme - H3C S5150-EI Series Installation Manual

Hide thumbs Also See for S5150-EI Series:
Table of Contents

Advertisement

Identifying physical IRF ports on the member switches

Identify the physical IRF ports on the member switches according to your topology and connection
scheme.
Table 7
shows the physical ports that can be used for IRF connection and the port use restrictions.
Table 7 Physical IRF port requirements
Chassis
S5150X-16S-EI
S5150X-16ST-EI
S5150-24S-PWR-EI

Planning the cabling scheme

Use twisted pair cables, SFP+ network cables, or SFP+ transceiver modules and fibers to connect
the IRF member switches. If the IRF member switches are far away from one another, choose SFP+
transceiver modules with optical fibers. If the IRF member switches are all in one equipment room,
choose twisted pair cables or SFP+ network cables. For more information about SFP+ network
cables and SFP+ transceiver modules, see
The following subsections describe several recommended IRF connection schemes, and all these
schemes use a ring topology.
Connecting the IRF member switches in one rack
Use SFP+ network cables to connect the IRF member switches (9 switches in this example) in a rack
as shown in
connected in the rack.
Candidate physical IRF ports
16 fixed SFP+ ports on the front panel
4 fixed SFP+ ports and 12 fixed
1/10GBASE-T autosensing Ethernet
ports on the front panel
4 fixed SFP+ ports on the front panel
Figure
47. The switches in the ring topology (see
Requirements
All physical ports to be bound to an IRF
port must be the same type.
"Appendix C Ports and
Figure
35
LEDs."
48) are in the same order as

Advertisement

Table of Contents
loading

Table of Contents