Connecting the power cord
CAUTION:
•
The AC power cord for the PSR150-A1 uses C13 connector, while the AC power cord for the
PSR360-56A/PSR720-56A/PSR1110-56A uses high-temperature C15 connector. Do not mix them.
•
Provide a circuit breaker for each power module and make sure the circuit breaker is off before installation.
Table 5 Power cord connection procedures at a glance
Switch
S5150X-16ST-EI
S5150X-16S-EI
S5150-24S-PWR-EI
Connecting an AC power cord to the switch
To connect an AC power cord to a switch that uses fixed power modules:
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
1.
Attach the hooks of the bail latch into the holes on the two sides of the AC-input power
2.
receptacle, and pull the bail latch upwards (see
Connect one end of the AC power cord to the AC-input power receptacle on the switch (see
3.
callout 1 in
Pull the bail latch down to secure the plug to the power receptacle (see callout 2 in
4.
Connect the other end of the power cord to the AC power outlet.
5.
Figure 31 Connecting an AC power cord to the switch (1)
Power mode
AC input
+12 VDC RPS input
(RPS800-A)
PSR150-A1
PSR150-D1: –48 VDC input
(External RPS power module:
RPS800-A or RPS1600-A)
PSR360-56A
PSR720-56A
PSR1110-56A
Figure
32).
Connection procedure reference
Connecting an AC power cord to the switch
Connecting a DC power cord to the switch
Connecting the PSR150-A1
Connecting the PSR150-D1
Connecting the
PSR360-56A/PSR720-56A/PSR1110-56A
Figure
31).
22
Figure
32).