FEDERAL COMMUNICATIONS COMMISSION FEDERAL COMMUNICATIONS COMMISSION TABLE OF CONTENTS TABLE OF CONTENTS (FCC) STATEMENT (FCC) STATEMENT This Equipment has been tested and found to comply with the limits for a class B Getting Started digital device, pursuant to Part 15 of the FCC rules. These limits are designed Quick Installation Guide (QIG) to provide reasonable protection against harmful interference in a residential Installing Software and Driver...
Power Cord. • • USB 2.0 Cable. • • • • CyberView Application software CD. Printed User’s Manual. • • WARRANTY INFORMATION NOTICE NOTE: Pacifi c Image warrants this product to be free from defects of material and workmanship for 1 year from the date of purchase.
Notice: 1. In “Found New Hardware Wizard” window, select “Search automatically or NOTE: Make sure the scanner is NOT connected to the computer during the CyberView Browse computer for driver software. ” driver installation. 2. In “Completing the Found New Hardware Wizard” window, click c.
Loading slide(s) into the magazine Loading slide(s) into the magazine CS Magazine General Recommendations: a. Locate the numbering sequence text on the CS slide magazine indicating the Braun Paximat S (White tray) especially for cardboard frames and framed • • slide order.
Page 6
Loading slide(s) into the magazine LKM Magazine a. Locate the numbering sequence text on the front of the LKM slide magazine indicating the slide order. The numbers should be facing forward and starting from the right b. Hold the slide right side up, facing backward so the image is reversed. Rotate the slide as illustrated and Insert each slide, one at a time, into the magazine.
Page 7
Load the magazine into the scanner LKM Magazine (Continued) Turn the slide tray around so the numbers face the front of the device, before inserting Compact Magazine (embossed letters facing up and the white stripe near the front panel of the scanner). Numbering Universal Magazine NOTE:...
USB port for the Film scanner to work properly, One Button Scan Slide Holder 1. Open the CyberView (Ref. page 16 to acquire the CyberView driver program) Eject 2. Confi gure Scan Settings (see Page 17) Button 3.
Notice: Higher scanning resolutions result in greater scanning time and hardisk (For PC User) space requirements. Open CyberView from Start – All Programs –CyberView b. Color Depth (For MAC User) The Film Scanner color depth is 48 bit true color Open Macintosh Hard drive –...
STEP 5 – Set Scan Preferences 4. Options - Use Film Index: Use the number assigned to the slide based on it’s position in the cartridge. Select Scan - Preference - Film Type - Scan Setting User Defi ned Start Number: Enter a specifi c start number 5.
Windows: C:\Users\[YOUR NAME\Documents; adjustment, resulting in vibrant images with optimal brightness, contrast and MAC: Mac HD\Users\[YOUR NAME]\Pictures\Cyberview Images), saturation. Select “Scan > Exit” to close the driver. Scanned image fi les can be open/edited with any image editing software.
Menu Commands - Preview USER INTERFACE USER INTERFACE 1. Zoom In: Magnify image. 2. Zoom Out: Reduce image. 3. Rotate 90 Left: Turn the image 90° counter clockwise. 4. Rotate 90 Right: Turn the image 90° clockwise. 5. Flip Horizontal: Flip the image horizontally. 6.
Page 13
2. Color Balance 3. Curves and Levels To adjust the brightness, contrast, saturation, and color (CMY or RGB) Adjust image settings by moving Curve and Levels settings. of the image. Comparisons between before and after adjusted images Comparison between before and after adjustment is displayed for are shown for reference.
Menu Commands - Windows Function Bar Diagram Exposure Setting: To adjust the exposure time (R, G, B) press ”Reset” to restore to In order to optimize scanned image quality, please select your fi lm type the default setting. and brand from the toolbar: Negative Positive (also known as Slide) Black and White...
Preview Window III. Active Frame Setting Area [Floating Windows] A comprehensive advanced mode is available to allow for more user defi ned Preview the image you pre-scan, you can select the measurement unit “in“-“cm“- adjustments. “px“ by clicking the upper-left corner. Normal mode [ex: I] to input the basic parameter to scan (including scan resolution, fi lm size, color depth).
IV. Thumbnail Panel Area [Floating Windows] Images only appear here in Prescan mode, scan to fi le goes directly to the hard drive, this window remains blank as does the main Cyberview window. Displays thumbnail view of pre-scanned images. By default all pre-scanned images are selected.
TECHNICAL SUPPORT TECHNICAL SUPPORT CyberView For information regarding the fi lm scanner and CyberView driver, please visit www.scanace.com Transportation For safety purposes, follow the procedure below before transporting the scanner (i.e. before moving the scanner from one location to another or packing and shipping the unit): 1.
Need help?
Do you have a question about the X5-MS and is the answer not in the manual?
Questions and answers