36" and 30" cooktop/downdraft system counter installation
C
D
JVB98SH/94SH, JVB67H/37H
E
F
Island or
Peninsula*
36"/30"
D
2-1/4"
6-3/8"
Vent
C
12-3/8"
G
Max.
Island or
Peninsula*
F
D
Dim. D to
Cutout
Cooktop
3/4" Thick
Support Rail
2-1/4
36" Models
6-3/8
12-3/8
Electric
27
Downdraft Vent
JP980S/JP960S/JP970S
7
JP980/JP960/JP970
JP655S
JP655
24-3/4
JP626
6" Dia. or 3-1/4" x 10"
Gas
Rectangular Duct required.
JGP975/JGP963/
JGP637/JGP630/JGP628
JGP970S
JGP970
30" Models
Electric
JP950S/JP940S/
JP930S/JP910S
JP950/JP940/
24"
JP930/JP910
JP355
JP340
Gas
JGP933/JGP337/
JGP330/JGP328
JGP940S
JGP940
JGP321
* Raised edge bull nose countertops may require up to 3/8" additional clearance to prevent
interference with curved front.
H
= 27-1/2"
G
= 34" for 36" models
H
33-7/8" for 30" models
No Gas or Electric
2-1/8"*
Service Inside
Shaded Area
G
8-1/2" Lift
14-3/4"
27"
H
E
I
= 29-1/2"
*Includes 1/8" required gap
C
L
J
between cooktop and vent trim.
= 32-1/4"
No Gas or Electric
I
Service Inside
Shaded Area
J
Fig. 2
Overall Cutout Dimensions
Planning Installation
"A" Fig. 1
"B" Fig. 1
Island or
Peninsula*
*These vents are recommended
Minimum
for island installation. Against the
Inside Cabinet
wall installations are limited due
Cooktop
Cooktop
to dimension requirements. Refer
Clearance
to installation instructions, packed
Overall Width
Overall Depth
with product, for further details.
36-1/8"
21-1/4"
36"
21-3/16"
36-1/8"
20-7/16"
36"
20-3/8"
35-1/2"
36"
36"
21-1/4"
36"
21-3/16"
29-7/8"
21-1/2"
29-3/4"
21-7/16"
29-3/4"
20-7/8"
29-3/4"
20-7/8"
30"
29-3/4"
21-3/8"
29-3/4"
21-7/16"
30-1/4"
21-1/4"
Flat Surface Area
24"
Note: The countertop must be at least 26" deep with a flat surface area
of 23-1/2" or more, front to back. In addition, other clearances to the
front edge must be considered.
Note: JP950S, JP940S, JP930S, JP910S, JGP940S require 23-5/8" flat
surface area.
Note: See specific cutout illustrations with your cooktop model to
determine requirements.
Note: A countertop with a raised or a rolled front edge may not allow
Vent
enough flat area for installation.
** Includes 1/8" required
Cookt op
gap between cooktop
and vent trim.
D
J
= 29-1/2
E
"B" & Vent Fig. 1
F
K
= 34" For 36" Models
Overall
28-1/2" For 30" Models
J
Surface Depth
No Gas or Electric
Cooktop
Service Inside
Shaded Area
K
Depth + Vent
Cover Depth
25 -1/4"
24-5/8"
21"
25-1/4"
21"
25-1/4"
24-11/16"
24-11/16"
25-3/4"
25-1/8"
25-1/2"
25-1/2"
21"
25-1/4"
25-1/4"
25-1/4"
25-1/2"
Preparing Cutout
"C" Fig. 2
"D" Fig. 2
Min. required
setback from
front edge
Countertop
to front edge
inside cabinet
of cutout
clearance
2-1/2"*
22-11/16"
2-1/2"*
22-11/16"
2-1/2"
22-11/16"
2-1/2"
22-11/16"
2-1/2"*
22-11/16"
2-1/2"*
22-11/16"
2-1/2"*
22-7/16"
2-1/2"*
22-7/16"
2-1/2"
22-7/16"
2-1/2"
22-7/16"
2-1/2"
22-7/16"
2-1/2"*
22-7/16"
2-1/2"*
22-7/16"
3-1/4"
22-7/16"
Required to
maintain U.L. or
AGA approvals.